<?xml version="1.0" encoding="UTF-8"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-19T01:36:02Z</responseDate><request verb="GetRecord" identifier="oai:ebyu-rdlopen.rawdatalibrary.net:ebyu/12068" metadataPrefix="oai_dc">https://ebyu-rdlopen.rawdatalibrary.net/oai/request</request><GetRecord><record><header><identifier>oai:ebyu-rdlopen.rawdatalibrary.net:ebyu/12068</identifier><datestamp>2026-10-18T20:43:16Z</datestamp><setSpec>openaire</setSpec><setSpec>driver</setSpec><setSpec>com_ebyu_10000</setSpec><setSpec>col_ebyu_10001</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:title>Detection of the glenoid bare spot by non-arthrographic MR imaging, conventional MR arthrography, and 3D high-resolution T1-weighted VIBE MR arthrography: comparison with CT arthrography</dc:title><dc:creator>Ozel, Mehmet Ali</dc:creator><dc:creator>Ogul, Hayri</dc:creator><dc:creator>Koksal, Ali</dc:creator><dc:creator>Kose, Mehmet</dc:creator><dc:creator>Tuncer, Kutsi</dc:creator><dc:creator>Eren, Suat</dc:creator><dc:creator>Kantarci, Mecit</dc:creator><dc:subject>Arthrography</dc:subject><dc:subject>Glenoid cavity</dc:subject><dc:subject>Magnetic resonance imaging</dc:subject><dc:subject>Tomography</dc:subject><dc:subject>Humans</dc:subject><dc:subject>Imaging, Three-Dimensional</dc:subject><dc:subject>Retrospective Studies</dc:subject><dc:subject>Tomography, X-Ray Computed</dc:subject><dc:subject>adult</dc:subject><dc:subject>article</dc:subject><dc:subject>breath holding</dc:subject><dc:subject>controlled study</dc:subject><dc:subject>diagnosis</dc:subject><dc:subject>diagnostic accuracy</dc:subject><dc:subject>diagnostic error</dc:subject><dc:subject>diagnostic test accuracy study</dc:subject><dc:subject>diagnostic value</dc:subject><dc:subject>female</dc:subject><dc:subject>human</dc:subject><dc:subject>interrater reliability</dc:subject><dc:subject>major clinical study</dc:subject><dc:subject>male</dc:subject><dc:subject>nuclear magnetic resonance imaging</dc:subject><dc:subject>radiologist</dc:subject><dc:subject>retrospective study</dc:subject><dc:subject>T1 weighted imaging</dc:subject><dc:subject>procedures</dc:subject><dc:subject>three-dimensional imaging</dc:subject><dc:subject>x-ray computed tomography</dc:subject><dc:description>Objectives: To determine the diagnostic accuracy of non-arthrographic MR imaging, conventional MR arthrography, and 3D T1-weighted volumetric interpolated breath-hold examination (VIBE) MR arthrography sequences as compared with a CT arthrography in the diagnosis of glenoid bare spot. Methods: A retrospective study of 216 patients who underwent non-arthrographic MR imaging, conventional MR arthrography, VIBE MRI arthrography, and CT arthrogram between January 2011 and March 2022 was conducted. The diagnostic accuracy of non-arthrographic MR imaging, direct MR arthrography, and VIBE MRI arthrography in the detection of glenoid bare spot was compared with that of CT arthrography. All studies were reviewed by 2 MSK radiologists. Interobserver agreement for MR imaging and MR arthrographic findings was calculated. Results: Sixteen of 216 patients were excluded. Twenty-three of 200 shoulders had glenoid bare spot on CT arthrographic images. The glenoid bare spot was detected in 11 (47.8%) and 7 (30.4%) patients on conventional non-arthrographic MR images and in 18 (78.3%) and 16 (69.6%) patients on conventional MR arthrograms by observers 1 and 2, respectively. Both observers separately described the bare spot in 22 of 23 patients (95.7%) on 3D volumetric MR arthrograms. Interobserver variabilities were fair agreement for conventional non-arthrographic MR imaging (κ = 0.35, p &lt; 0.05), moderate agreement for conventional MR arthrogram (κ = 0.50, p &lt; 0.05), and near-perfect agreement for 3D volumetric MR arthrogram reading (κ = 0.87, p &lt; 0.05). Conclusions: A 3D high-resolution T1-weighted VIBE MR arthrography sequence may yield diagnostic performance that is comparable with that of CT arthrography in the diagnosis of glenoid bare spot. Key Points: •Glenoid bare spot should not be misdiagnosed as a transchondral defect of the glenoid surface by radiologists. •A 3D high-resolution T1-weighted VIBE MR arthrography sequence may be used as a high-sensitivity imaging technique in the diagnosis of glenoid bare spot. © 2023, The Author(s), under exclusive licence to European Society of Radiology.</dc:description><dc:publisher>Springer Science and Business Media Deutschland GmbH</dc:publisher><dc:date>2023</dc:date><dc:type>Article</dc:type><dc:identifier>https://rdlopen.rawdatalibrary.net/r/ebyu/12068</dc:identifier><dc:identifier>https://doi.org/10.1007/s00330-023-09443-0</dc:identifier><dc:identifier>0938-7994</dc:identifier><dc:language>en</dc:language><dc:relation>European Radiology</dc:relation><dc:rights>info:eu-repo/semantics/openAccess</dc:rights><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://ebyu-rdlopen.rawdatalibrary.net/tr/items/ebyu/12068</dc:identifier></oai_dc:dc></metadata></record></GetRecord></OAI-PMH>