<?xml version="1.0" encoding="UTF-8"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-18T23:51:06Z</responseDate><request verb="GetRecord" identifier="oai:ebyu-rdlopen.rawdatalibrary.net:ebyu/12359" metadataPrefix="oai_dc">https://ebyu-rdlopen.rawdatalibrary.net/oai/request</request><GetRecord><record><header><identifier>oai:ebyu-rdlopen.rawdatalibrary.net:ebyu/12359</identifier><datestamp>2026-10-18T20:33:42Z</datestamp><setSpec>openaire</setSpec><setSpec>driver</setSpec><setSpec>com_ebyu_10000</setSpec><setSpec>col_ebyu_10001</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:title>Construction of a novel Cu(II)-selective electrode with long life span based on 8-aminoquinoline functionalized bentonite</dc:title><dc:creator>Dogan, Bilge</dc:creator><dc:creator>Coldur, Fatih</dc:creator><dc:creator>Caglar, Bulent</dc:creator><dc:creator>Ozdemir, Agah Oktay</dc:creator><dc:creator>Guner, Eda Keles</dc:creator><dc:creator>Ozdokur, Kemal Volkan</dc:creator><dc:subject>8-Aminoquinoline</dc:subject><dc:subject>Carboxylated PVC</dc:subject><dc:subject>Copper(II) detection</dc:subject><dc:subject>Functionalized-bentonite</dc:subject><dc:subject>Potentiometric electrode</dc:subject><dc:description>A novel 8-aminoquinoline-functionalized bentonite was utilized as an electroactive sensing element in the construction of a potentiometric carboxylated-PVC-based polymeric membrane electrode. The electrode exhibited a linear response for copper(II) ions in the concentration range of 1.0 × 10–5−1.0 × 10–2 mol/dm3 with a slope of 28.24 mV/decade. While the response time of the electrode determined as about 20 s, its detection limit and long life time was determined as 5.0 × 10–6 mol/dm3 and 5 months, respectively. The proposed electrode was applied for the potentiometric detection of Cu(II) contents of some spiked water samples and satisfied results were attained. Graphical abstract: [Figure not available: see fulltext.] © 2022, Springer-Verlag GmbH Austria, part of Springer Nature.</dc:description><dc:publisher>Springer</dc:publisher><dc:date>2023</dc:date><dc:type>Article</dc:type><dc:identifier>https://rdlopen.rawdatalibrary.net/r/ebyu/12359</dc:identifier><dc:identifier>https://doi.org/10.1007/s00706-022-03008-5</dc:identifier><dc:identifier>0026-9247</dc:identifier><dc:language>en</dc:language><dc:relation>Monatshefte fur Chemie</dc:relation><dc:rights>info:eu-repo/semantics/openAccess</dc:rights><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://ebyu-rdlopen.rawdatalibrary.net/tr/items/ebyu/12359</dc:identifier></oai_dc:dc></metadata></record></GetRecord></OAI-PMH>