<?xml version="1.0" encoding="UTF-8"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-19T02:04:01Z</responseDate><request verb="GetRecord" identifier="oai:ebyu-rdlopen.rawdatalibrary.net:ebyu/13819" metadataPrefix="oai_dc">https://ebyu-rdlopen.rawdatalibrary.net/oai/request</request><GetRecord><record><header><identifier>oai:ebyu-rdlopen.rawdatalibrary.net:ebyu/13819</identifier><datestamp>2026-10-18T20:39:14Z</datestamp><setSpec>openaire</setSpec><setSpec>driver</setSpec><setSpec>com_ebyu_10000</setSpec><setSpec>col_ebyu_10001</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:title>The effect of enhancement factor on the angular dependence of L x-ray intensity ratios for Sm, Hf, Pb and U</dc:title><dc:creator>Akkuş, Tuba</dc:creator><dc:creator>Yılmaz, Demet</dc:creator><dc:creator>Uğurlu, Mine</dc:creator><dc:subject>Angular dependence</dc:subject><dc:subject>Enhancement factor</dc:subject><dc:subject>L X-rays</dc:subject><dc:subject>Cerium oxide</dc:subject><dc:subject>Energy dispersive spectroscopy</dc:subject><dc:subject>X rays</dc:subject><dc:subject>hafnium</dc:subject><dc:subject>lead</dc:subject><dc:subject>samarium</dc:subject><dc:subject>uranium</dc:subject><dc:subject>Binary systems</dc:subject><dc:subject>Enhancement effects</dc:subject><dc:subject>Intensity ratio</dc:subject><dc:subject>Scattering angles</dc:subject><dc:subject>X-ray intensity ratios</dc:subject><dc:subject>Article</dc:subject><dc:subject>fluorescence</dc:subject><dc:subject>gamma radiation</dc:subject><dc:subject>geometry</dc:subject><dc:subject>photon</dc:subject><dc:subject>radiation scattering</dc:subject><dc:subject>radiological parameters</dc:subject><dc:subject>X ray</dc:subject><dc:subject>X ray detectors</dc:subject><dc:description>The effect of enhancement factor on the angular dependence of Ll/Lγ, Lα/Lγ and Lβ/Lγ X-ray intensity ratios for Sm, Hf, Pb and U elements have been measured by using the 59.54 keV photon energy. The binary systems are prepared as Sm-CeO2, Hf-CeO2, Pb–CeO2 and U–CeO2. The samples have been analyzed in EDXRF system. The measurements are made in scattering angles of 85°, 95°, 105°, 115° and 125°. The L X-ray spectra from different samples were detected by a Si(Li) detector. The results show that the intensity ratios of L X-rays to be greater than expected due to the enhancement effect. © 2019 Elsevier Ltd</dc:description><dc:publisher>Elsevier Ltd</dc:publisher><dc:date>2020</dc:date><dc:type>Article</dc:type><dc:identifier>https://rdlopen.rawdatalibrary.net/r/ebyu/13819</dc:identifier><dc:identifier>https://doi.org/10.1016/j.radphyschem.2019.108499</dc:identifier><dc:identifier>0969-806X</dc:identifier><dc:language>en</dc:language><dc:relation>Radiation Physics and Chemistry</dc:relation><dc:rights>info:eu-repo/semantics/openAccess</dc:rights><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://ebyu-rdlopen.rawdatalibrary.net/tr/items/ebyu/13819</dc:identifier></oai_dc:dc></metadata></record></GetRecord></OAI-PMH>