<?xml version="1.0" encoding="UTF-8"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-19T01:06:11Z</responseDate><request verb="GetRecord" identifier="oai:ebyu-rdlopen.rawdatalibrary.net:ebyu/14116" metadataPrefix="oai_dc">https://ebyu-rdlopen.rawdatalibrary.net/oai/request</request><GetRecord><record><header><identifier>oai:ebyu-rdlopen.rawdatalibrary.net:ebyu/14116</identifier><datestamp>2026-10-18T20:28:53Z</datestamp><setSpec>openaire</setSpec><setSpec>driver</setSpec><setSpec>com_ebyu_10000</setSpec><setSpec>col_ebyu_10001</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:title>Construction of a novel highly selective potentiometric perchlorate sensor based on neocuproine-Cu(II) complex formed in situ during the conditioning period</dc:title><dc:creator>Onder, Ahmet</dc:creator><dc:creator>Topcu, Cihan</dc:creator><dc:creator>Coldur, Fatih</dc:creator><dc:subject>Electrode</dc:subject><dc:subject>Neocuproine</dc:subject><dc:subject>Perchlorate</dc:subject><dc:subject>Perchlorate determination</dc:subject><dc:subject>Potentiometry</dc:subject><dc:description>A potentiometric perchlorate-selective electrode based on a phenanthroline derivative, neocuproine (2,9-dimethyl-1,10-phenanthroline), was developed. An electroactive substance, a neocuproine complex of Cu2+, providing a selective response to perchlorate was formed in situ in the electrode membrane structure during the conditioning process. Membrane optimization studies showed that the most suitable membrane composition was 1.0% (w/w) neocuproine, 69.0% (w/w) o-nitrophenyloctylether (o-NPOE) and 30.0% (w/w) poly(vinyl chloride) (PVC) in terms of potentiometric performance characteristics. For the proposed electrode, the linear range, slope, detection limit, pH working range and response time were determined as 2.5 × 10-7-1.0 × 10-1 M, -53.01 mV/decade, 1.0 × 10-7 M, 4.0-12.5 and ≈3 s, respectively. The proposed sensor was successfully used in the determination of perchlorate contents of some perchlorate spiked tap, river and dam water samples. © Lietuvos mokslu akademija, 2018.</dc:description><dc:publisher>Lietuvos Mokslu Akademijos</dc:publisher><dc:date>2018</dc:date><dc:type>Article</dc:type><dc:identifier>https://rdlopen.rawdatalibrary.net/r/ebyu/14116</dc:identifier><dc:identifier>0235-7216</dc:identifier><dc:language>en</dc:language><dc:relation>Chemija</dc:relation><dc:rights>info:eu-repo/semantics/openAccess</dc:rights><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://ebyu-rdlopen.rawdatalibrary.net/tr/items/ebyu/14116</dc:identifier></oai_dc:dc></metadata></record></GetRecord></OAI-PMH>