<?xml version="1.0" encoding="UTF-8"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-19T01:07:52Z</responseDate><request verb="GetRecord" identifier="oai:ebyu-rdlopen.rawdatalibrary.net:ebyu/14148" metadataPrefix="oai_dc">https://ebyu-rdlopen.rawdatalibrary.net/oai/request</request><GetRecord><record><header><identifier>oai:ebyu-rdlopen.rawdatalibrary.net:ebyu/14148</identifier><datestamp>2026-10-18T20:41:31Z</datestamp><setSpec>openaire</setSpec><setSpec>driver</setSpec><setSpec>com_ebyu_10000</setSpec><setSpec>col_ebyu_10001</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:title>Electrochemical Determination of Copper(II) in Water Samples Using a Novel Ion-Selective Electrode Based on a Graphite Oxide–Imprinted Polymer Composite</dc:title><dc:creator>Topcu, Cihan</dc:creator><dc:creator>Lacin, Gamze</dc:creator><dc:creator>Yilmaz, Vedat</dc:creator><dc:creator>Coldur, Fatih</dc:creator><dc:creator>Caglar, Bulent</dc:creator><dc:creator>Cubuk, Osman</dc:creator><dc:creator>Isildak, Ibrahim</dc:creator><dc:subject>Copper(II) determination</dc:subject><dc:subject>copper(II)-selective electrode</dc:subject><dc:subject>ion-imprinted polymer</dc:subject><dc:subject>potentiometry</dc:subject><dc:subject>water analysis</dc:subject><dc:description>A novel copper(II)-selective electrode based on graphite oxide/imprinted polymer composite was developed for the electrochemical monitoring of copper(II) (Cu2+) ions. The electrode exhibited highly selective potentiometric response to Cu2+ with respect to common alkaline, alkaline earth and heavy metal cations. The composite composition studies indicated that the most suitable composite composition performing the most promising potentiometric properties was 20.0% ionophore (Cu2+-ion imprinted polymer), 10.0% paraffin oil, 5.0% multiwalled carbon nanotubes, and 65.0% graphite oxide. The fabricated electrode exhibited a linear response to Cu2+ over the concentration range of 1.0 × 10− 6–1.0 × 10− 1 M (correlation coefficient of 0.9998) with a sensitivity of 26.1 ± 0.9 mV decade− 1. The detection limit of the fabricated electrode was determined to be 4.0 × 10− 7 M. The electrode worked well in the pH range of 4.0–8.0. The electrode had stable, reversible and fast potentiometric response (3 s). In addition, the electrode had a lifetime of more than 1 year. The analytical applications of the proposed electrode were performed using as an indicator electrode for the potentiometric titration of Cu2+ with ethylene diamine tetraacetic acid solution and for the determination of Cu2+ of spiked river, dam, and tap water samples. The obtained results for potentiometric titration and water samples were satisfactory. © 2017 Taylor &amp; Francis.</dc:description><dc:publisher>Taylor and Francis Inc.</dc:publisher><dc:date>2018</dc:date><dc:type>Article</dc:type><dc:identifier>https://rdlopen.rawdatalibrary.net/r/ebyu/14148</dc:identifier><dc:identifier>https://doi.org/10.1080/00032719.2017.1395035</dc:identifier><dc:identifier>0003-2719</dc:identifier><dc:language>en</dc:language><dc:relation>Analytical Letters</dc:relation><dc:rights>info:eu-repo/semantics/openAccess</dc:rights><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://ebyu-rdlopen.rawdatalibrary.net/tr/items/ebyu/14148</dc:identifier></oai_dc:dc></metadata></record></GetRecord></OAI-PMH>