<?xml version="1.0" encoding="UTF-8"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-19T06:00:15Z</responseDate><request verb="GetRecord" identifier="oai:ebyu-rdlopen.rawdatalibrary.net:ebyu/15098" metadataPrefix="oai_dc">https://ebyu-rdlopen.rawdatalibrary.net/oai/request</request><GetRecord><record><header><identifier>oai:ebyu-rdlopen.rawdatalibrary.net:ebyu/15098</identifier><datestamp>2026-10-18T21:14:27Z</datestamp><setSpec>openaire</setSpec><setSpec>driver</setSpec><setSpec>com_ebyu_10000</setSpec><setSpec>col_ebyu_10001</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:title>Surgical removal of guidewire entrapped within stent struts during percutaneous coronary angioplasty</dc:title><dc:creator>Alper, Onk Oruc</dc:creator><dc:creator>Mehmet, Aksüt</dc:creator><dc:creator>Murat, Bakirci Eftal</dc:creator><dc:creator>Halil, Ekren</dc:creator><dc:creator>Bilgehan, Erkut</dc:creator><dc:subject>Acute Coronary Syndrome</dc:subject><dc:subject>Angioplasty, Balloon, Coronary</dc:subject><dc:subject>Coronary Artery Bypass</dc:subject><dc:subject>Device Removal</dc:subject><dc:subject>Humans</dc:subject><dc:subject>Male</dc:subject><dc:subject>Middle Aged</dc:subject><dc:subject>Stents</dc:subject><dc:subject>anticoagulant agent</dc:subject><dc:subject>beta adrenergic receptor blocking agent</dc:subject><dc:subject>coronary vasodilating agent</dc:subject><dc:subject>polypropylene</dc:subject><dc:subject>troponin I</dc:subject><dc:subject>adult</dc:subject><dc:subject>angiocardiography</dc:subject><dc:subject>anticoagulant therapy</dc:subject><dc:subject>Article</dc:subject><dc:subject>artificial embolism</dc:subject><dc:subject>balloon dilatation</dc:subject><dc:subject>case report</dc:subject><dc:subject>coronary artery blood flow</dc:subject><dc:subject>coronary artery bypass graft</dc:subject><dc:subject>coronary artery circumflex branch</dc:subject><dc:subject>coronary artery occlusion</dc:subject><dc:subject>coronary stent</dc:subject><dc:subject>emergency surgery</dc:subject><dc:subject>guidewire entrapment</dc:subject><dc:subject>hematoma</dc:subject><dc:subject>human</dc:subject><dc:subject>medical device complication</dc:subject><dc:description>There has been a growing trend toward percutaneous coronary angioplasty for complex coronary artery lesions. Stent or guidewire break off or trapping within the coronary artery lumen is a rare complication, but it may have fatal consequences. In such cases, the entrapped device may be removed by either percutaneous route or surgical exploration. Here, we report a patient with guidewire entrapment within the struts of the intracoronary stent during primary percutaneous coronary angioplasty, which necessitated surgical removal and subsequent coronary artery bypass grafting (CABG). © 2015 Forum Multimedia Publishing, LLC.</dc:description><dc:publisher>Carden Jennings Publishing Co. Ltd</dc:publisher><dc:date>2015</dc:date><dc:type>Article</dc:type><dc:identifier>https://rdlopen.rawdatalibrary.net/r/ebyu/15098</dc:identifier><dc:identifier>https://doi.org/10.1532/hsf.1253</dc:identifier><dc:identifier>1098-3511</dc:identifier><dc:language>en</dc:language><dc:relation>Heart Surgery Forum</dc:relation><dc:rights>info:eu-repo/semantics/openAccess</dc:rights><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://ebyu-rdlopen.rawdatalibrary.net/tr/items/ebyu/15098</dc:identifier></oai_dc:dc></metadata></record></GetRecord></OAI-PMH>