<?xml version="1.0" encoding="UTF-8"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-18T23:15:52Z</responseDate><request verb="GetRecord" identifier="oai:ebyu-rdlopen.rawdatalibrary.net:ebyu/15518" metadataPrefix="oai_dc">https://ebyu-rdlopen.rawdatalibrary.net/oai/request</request><GetRecord><record><header><identifier>oai:ebyu-rdlopen.rawdatalibrary.net:ebyu/15518</identifier><datestamp>2026-10-18T21:14:30Z</datestamp><setSpec>openaire</setSpec><setSpec>driver</setSpec><setSpec>com_ebyu_10000</setSpec><setSpec>col_ebyu_10001</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:title>Comparison of central corneal thickness measurements by Galilei Dual-Scheimpflug Analyzer® and ultrasound pachymeter in myopic eyes</dc:title><dc:creator>Yeter, Volkan</dc:creator><dc:creator>Sönmez, Baris</dc:creator><dc:creator>Beden, Ümit</dc:creator><dc:subject>Adolescent</dc:subject><dc:subject>Adult</dc:subject><dc:subject>Cornea</dc:subject><dc:subject>Diagnostic Techniques, Ophthalmological</dc:subject><dc:subject>Female</dc:subject><dc:subject>Humans</dc:subject><dc:subject>Male</dc:subject><dc:subject>Myopia</dc:subject><dc:subject>Photography</dc:subject><dc:subject>Prospective Studies</dc:subject><dc:subject>Regression Analysis</dc:subject><dc:subject>Ultrasonography</dc:subject><dc:subject>Young Adult</dc:subject><dc:subject>analytical equipment</dc:subject><dc:subject>analyzer</dc:subject><dc:subject>article</dc:subject><dc:subject>bland altman plot</dc:subject><dc:subject>controlled study</dc:subject><dc:subject>cornea thickness</dc:subject><dc:subject>correlation coefficient</dc:subject><dc:subject>data analysis</dc:subject><dc:subject>human</dc:subject><dc:subject>major clinical study</dc:subject><dc:subject>priority journal</dc:subject><dc:subject>prospective study</dc:subject><dc:subject>refractive surgery</dc:subject><dc:subject>statistical analysis</dc:subject><dc:subject>Student t test</dc:subject><dc:subject>ultrasound pachymeter</dc:subject><dc:description>■ BACKGROUND AND OBJECTIVE: To compare the central corneal thickness (CCT) measurements by Galilei Dual-Scheimpflug analyzer (GSA) (Ziemer Group, Port, Switzerland) and ultrasound pachymeter (UP) in myopic eyes. ■ PATIENTS AND METHODS: In this prospective study, CCT of 161 myopic eyes of 81 refractive surgery candidates (35 female, 46 male; mean age: 23.18 ± 4.08 years) were measured by GSA and UP consecutively. The data were analyzed statistically by paired t test, Bland-Altman plot, and Pearson correlation test to assess the agreement of the measurements. ■ RESULTS: The mean CCTs obtained by GSA and UP were 559.85 ± 30.87 and 560.41 ± 34.45 μm, respectively. No significant difference was found between the measurements (P = .684) and regression analysis showed a high correlation between the measurements obtained with both devices (r = 0.86; P &lt; .001). A strong agreement between the two methods was also found by Bland-Altman plot. ■ CONCLUSION: In myopic eyes, the CCT measurements of GSA and UP are similar and highly correlated. Because of high agreement between these devices, the GSA is a non-contact method that may be an alternative to UP for measurement of CCT. Copyright © SLACK Incorporated.</dc:description><dc:date>2012</dc:date><dc:type>Article</dc:type><dc:identifier>https://rdlopen.rawdatalibrary.net/r/ebyu/15518</dc:identifier><dc:identifier>https://doi.org/10.3928/15428877-20120102-08</dc:identifier><dc:identifier>1542-8877</dc:identifier><dc:language>en</dc:language><dc:relation>Ophthalmic Surgery Lasers and Imaging</dc:relation><dc:rights>info:eu-repo/semantics/openAccess</dc:rights><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://ebyu-rdlopen.rawdatalibrary.net/tr/items/ebyu/15518</dc:identifier></oai_dc:dc></metadata></record></GetRecord></OAI-PMH>