<?xml version="1.0" encoding="UTF-8"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-19T01:08:38Z</responseDate><request verb="GetRecord" identifier="oai:ebyu-rdlopen.rawdatalibrary.net:ebyu/15861" metadataPrefix="oai_dc">https://ebyu-rdlopen.rawdatalibrary.net/oai/request</request><GetRecord><record><header><identifier>oai:ebyu-rdlopen.rawdatalibrary.net:ebyu/15861</identifier><datestamp>2026-10-18T20:39:03Z</datestamp><setSpec>openaire</setSpec><setSpec>driver</setSpec><setSpec>com_ebyu_10000</setSpec><setSpec>col_ebyu_10001</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:title>A Flow-Injection Potentiometric System for Selective and Sensitive Determination of Serum Lithium Level</dc:title><dc:creator>Coldur, Fatih</dc:creator><dc:creator>Andac, Muberra</dc:creator><dc:subject>Experimental design</dc:subject><dc:subject>Flow injection analysis</dc:subject><dc:subject>Lithium determination</dc:subject><dc:subject>Multivariate optimization</dc:subject><dc:subject>Serum analysis</dc:subject><dc:subject>Body fluids</dc:subject><dc:subject>Multivariant analysis</dc:subject><dc:subject>Potentiometers (electric measuring instruments)</dc:subject><dc:subject>Flow injection</dc:subject><dc:subject>Flow-injection system</dc:subject><dc:subject>Li +</dc:subject><dc:subject>Potentiometric flows</dc:subject><dc:subject>Potentiometrics</dc:subject><dc:subject>Serum samples</dc:subject><dc:subject>Lithium</dc:subject><dc:description>A potentiometric flow injection system was adopted by using a Li+-selective electrode with improved selectivity for sensitive and selective determination of Li+ in human serum spiked samples. For the optimization of the offered flow injection system, multivariate method was utilized. Potentiometric characteristics of the system were investigated (linear range: 5.0×10-5-1.0×10-1molL-1, slope: 56.93mV per decade, detection limit: 3.4×10-5molL-1, sampling-rate: 40 injections per hour). The detection of Li+ in real serum samples was achieved. The obtained results for the spiked serum samples were in good agreement with IC results at 95% confidence level. © 2013 WILEY-VCH Verlag GmbH &amp; Co. KGaA, Weinheim.</dc:description><dc:publisher>Wiley-VCH Verlag</dc:publisher><dc:date>2013</dc:date><dc:type>Article</dc:type><dc:identifier>https://rdlopen.rawdatalibrary.net/r/ebyu/15861</dc:identifier><dc:identifier>https://doi.org/10.1002/elan.201200466</dc:identifier><dc:identifier>1040-0397</dc:identifier><dc:language>en</dc:language><dc:relation>Electroanalysis</dc:relation><dc:rights>info:eu-repo/semantics/openAccess</dc:rights><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://ebyu-rdlopen.rawdatalibrary.net/tr/items/ebyu/15861</dc:identifier></oai_dc:dc></metadata></record></GetRecord></OAI-PMH>