<?xml version="1.0" encoding="UTF-8"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-19T01:04:12Z</responseDate><request verb="GetRecord" identifier="oai:ebyu-rdlopen.rawdatalibrary.net:ebyu/16048" metadataPrefix="oai_dc">https://ebyu-rdlopen.rawdatalibrary.net/oai/request</request><GetRecord><record><header><identifier>oai:ebyu-rdlopen.rawdatalibrary.net:ebyu/16048</identifier><datestamp>2026-10-18T20:30:53Z</datestamp><setSpec>openaire</setSpec><setSpec>driver</setSpec><setSpec>com_ebyu_10000</setSpec><setSpec>col_ebyu_10001</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:title>The efficiency determination for Si(Li) detector in the 3-723 keV energy range</dc:title><dc:creator>Yalçin, P.</dc:creator><dc:creator>Sülün, A.</dc:creator><dc:creator>Baştuǧ, A.</dc:creator><dc:creator>Kurucu, Y.</dc:creator><dc:creator>Şahin, Y.</dc:creator><dc:subject>γ- and X-rays emission probabilities</dc:subject><dc:subject>Efficiency calibration</dc:subject><dc:subject>Gamma-ray spectrometry</dc:subject><dc:subject>Photopeak efficiency</dc:subject><dc:subject>Si(Li) detector efficiency</dc:subject><dc:description>The photopeak efficiency of a Si(Li) detector was determined experimentally for 3-723 keV photon energy by using liquid radioisotopes 51Cr, 67Ga, 99Tc, 111In, 131I, 201Tl and polyester coated radioisotopes 55Fe, 137Cs, 133Ba, 241Am. The efficiency for γ- and X-rays emitted in the decay of the radioactive sources was obtained from measurements. The efficiency values were established at 49 energies ranging from about 3 to 723 keV. The experimental values were fitted to an analytical function of photon energy and an agreement was observed for the entire range of the studied energies.</dc:description><dc:date>2005</dc:date><dc:type>Article</dc:type><dc:identifier>https://rdlopen.rawdatalibrary.net/r/ebyu/16048</dc:identifier><dc:identifier>1205-6685</dc:identifier><dc:language>en</dc:language><dc:relation>Canadian Journal of Analytical Sciences and Spectroscopy</dc:relation><dc:rights>info:eu-repo/semantics/openAccess</dc:rights><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://ebyu-rdlopen.rawdatalibrary.net/tr/items/ebyu/16048</dc:identifier></oai_dc:dc></metadata></record></GetRecord></OAI-PMH>