Ensuring pharmaceutical safety: Highthroughput LC-MS/MS method for plastic additive detection

ArticleAçık Erişim

Özet

Extractables and Leachables studies require highly reliable and sensitive analytical methods to ensure pharmaceutical product safety. Plastic additives are widely used during production to improve the physicochemical properties of polymeric products. However, these additives may constitute a potential toxicological risk by contaminating active pharmaceutical ingredients and pharmaceutical preparations. In this study, a short-term, sensitive, accurate, and reliable LC-MS/MS method was developed for the analysis of 15 plastic additives defined in the European Pharmacopoeia and validated in accordance with the ICH Q2(R2) guideline. An electrospray ionization source was used for the analyses in both negative and positive modes. Chromatographic separation was carried out using a reverse-phase phenyl C18 column and a mixture of methanol and ultrapure water containing 5 mM ammonium acetate as the mobile phase by the gradient elution method. As a result of method optimization, the flow rate and total analysis time were determined to be 0.7 mL/min and 15 min, respectively. Diphenyl phthalate was chosen as the internal standard. The LLOQ values of plastic additives were generally determined as 50 ng/mL (150 ng/mL for oleamide). The reliability of the method was verified by intraday/interday precision and accuracy analyses. Both extractable and leachable studies were performed using the developed method. It was effectively used to detect plastic additive contamination in pharmaceutical products such as bromobutyl stoppers, LDPE containers, disposable eye drop packaging, and polypropylene bags. The developed LC-MS/MS method was successfully applied to the analysis of pharmaceutical formulations containing 1.4% polyvinyl alcohol and 0.6% povidone, sodium hyaluronate, salbutamol sulfate, and 0.9% isotonic sodium chloride. © 2025 American Pharmacists Association.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/10442Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1016/j.xphs.2025.104135Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorDemircioğlu, İbrahim Hakkı
dc.contributor.authorDalkılıç, Oğuzhan
dc.contributor.authorÇelik, Saffet
dc.contributor.authorAkman, Tugrul Cagri
dc.contributor.authorKılıç, Hamdullah
dc.contributor.authorKandemir, Levent
dc.contributor.authorAtila, Alptuğ
dc.date.accessioned2026-10-18T20:25:39.529076787Z
dc.date.available2026-10-18T20:25:39.529076787Z
dc.date.issued2026
dc.description.abstractExtractables and Leachables studies require highly reliable and sensitive analytical methods to ensure pharmaceutical product safety. Plastic additives are widely used during production to improve the physicochemical properties of polymeric products. However, these additives may constitute a potential toxicological risk by contaminating active pharmaceutical ingredients and pharmaceutical preparations. In this study, a short-term, sensitive, accurate, and reliable LC-MS/MS method was developed for the analysis of 15 plastic additives defined in the European Pharmacopoeia and validated in accordance with the ICH Q2(R2) guideline. An electrospray ionization source was used for the analyses in both negative and positive modes. Chromatographic separation was carried out using a reverse-phase phenyl C18 column and a mixture of methanol and ultrapure water containing 5 mM ammonium acetate as the mobile phase by the gradient elution method. As a result of method optimization, the flow rate and total analysis time were determined to be 0.7 mL/min and 15 min, respectively. Diphenyl phthalate was chosen as the internal standard. The LLOQ values of plastic additives were generally determined as 50 ng/mL (150 ng/mL for oleamide). The reliability of the method was verified by intraday/interday precision and accuracy analyses. Both extractable and leachable studies were performed using the developed method. It was effectively used to detect plastic additive contamination in pharmaceutical products such as bromobutyl stoppers, LDPE containers, disposable eye drop packaging, and polypropylene bags. The developed LC-MS/MS method was successfully applied to the analysis of pharmaceutical formulations containing 1.4% polyvinyl alcohol and 0.6% povidone, sodium hyaluronate, salbutamol sulfate, and 0.9% isotonic sodium chloride. © 2025 American Pharmacists Association.
dc.description.sponsorshipFor their valuable support in the realization of this study; We would like to express our sincere gratitude to T\u00DCB\u0130TAK (B\u0130DEB 2244-Industrial Doctoral Scholarship Program and 2250-Graduate Scholarships Performance Program, Project No: 119C134), Polifarma Pharmaceutical Industry and Trade Inc., Atat\u00FCrk University BAP Coordinatorship (Project No: TDK-2022-10732) and Eastern Anatolia High Technology Application and Research Center (DAYTAM) for providing the research infrastructure.
dc.identifier.doi10.1016/j.xphs.2025.104135
dc.identifier.eissn1520-6017
dc.identifier.issn0022-3549
dc.identifier.issue2
dc.identifier.pmid41412534
dc.identifier.scopus2-s2.0-105025653718
dc.identifier.startpage104135
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/10442
dc.identifier.volume115
dc.identifier.wosWOS:001650082600001
dc.language.isoen
dc.publisherElsevier B.V.
dc.relation.ispartofJournal of Pharmaceutical Sciences
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectExtractables & leachables
dc.subjectLC-MS/MS
dc.subjectPackaging materials
dc.subjectPharmaceuticals
dc.subjectPlastic additives
dc.subjectValidation
dc.subjectChromatography, Liquid
dc.subjectDrug Contamination
dc.subjectLiquid Chromatography-Mass Spectrometry
dc.subjectPharmaceutical Preparations
dc.subjectPlastics
dc.subjectReproducibility of Results
dc.subjectTandem Mass Spectrometry
dc.subject3 (3,5 di tert butyl 4 hydroxyphenyl)propionic acid octadecyl ester
dc.subjectammonium acetate
dc.subjectbutyryl trihexyl citrate
dc.subjectcresol
dc.subjectdiphenyl pthalate
dc.subjectdryex
dc.subjecthostanox
dc.subjectnovaqua
dc.subjectpentaerythritol tetrakis[3 (3,5 di tert butyl 4 hydroxyphenyl)propionate]
dc.subjectpolifleks
dc.subjectpolypropylene
dc.subjectpolyvinyl alcohol
dc.subjectronkotol
dc.subjectstearic acid
dc.subjecttetrahydrofuran
dc.subjecttrimellitic acid tris(2 ethylhexyl) ester
dc.subjectunclassified drug
dc.titleEnsuring pharmaceutical safety: Highthroughput LC-MS/MS method for plastic additive detection
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus0
rdl.citation.wos0
rdl.departmentDepartment of Analytical Chemistry, Faculty of Pharmacy, Erzincan Binali Yildirim University, Erzincan, 24100, Turkiye.
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)