ESTIMATION OF ENERGY LOSS DUE TO LIGHT POLLUTION USING SATELLITE AND FIELD MEASUREMENT DATA: EXAMPLE OF ERZİNCAN CITY

ArticleAçık Erişim

Özet

In this study, we use field and satellite data to calculate the amount of energy wasted by faulty lighting and by light reflected from reflective surfaces and directed into upper half space, as well as its financial equivalent, although we do not address the consistency of the modeling used in the calculation for field and satellite data. In addition, light pollution in the city center of Erzincan and its surroundings was determined using data from SQM-LU and VIIRS, and the energy loss due to artificial lighting was calculated. To determine the effect of the change in zenith angle, SQM-LU measurements were made at distances of 5o between the zenith and the horizon at 4 points in the east, west, north, and south directions, while SQM-LU measurements were made at 45 points in the zenith direction. For the SQM measurements, the lowest (bright) and highest (dim) readings are 16.9 magnitude/arcsec2 and 20.30 magnitude/arcsec2, respectively, while according to the VIIRS satellite data they are 16.2 magnitude/arcsec2 and 18.9 magnitude/arcsec2, respectively. While the smallest value of the total luminous flux calculated for the city center of Erzincan and its surroundings (calculated from measurements in the zenith direction) is ~1.56 million lumens according to the SQM measurements, it is calculated to be ~5.98 million lumens according to the VIIRS satellite data. Taking into account the effect of 73% atmospheric transmittance and zenith angle dependence in the calculations, the total amount of luminous flux was calculated to be ~31.17 million lumens according to the SQM data and ~42.2 million lumens according to the VIIRS data. Considering that street lighting, billboards and outdoor lighting of buildings in the city are active for about 12 hours per day, the amount of wasted energy was calculated to be 112 219 kWh/month. A strong correlation was found between SQM and VIIRS values with R2 ≈0.71. © 2024 Gheorghe Asachi Technical University of Iasi, Romania. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/11300Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.30638/eemj.2024.205Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorYılmaz, Abdulvahap
dc.date.accessioned2026-10-18T20:26:22.313088195Z
dc.date.available2026-10-18T20:26:22.313088195Z
dc.date.issued2024
dc.description.abstractIn this study, we use field and satellite data to calculate the amount of energy wasted by faulty lighting and by light reflected from reflective surfaces and directed into upper half space, as well as its financial equivalent, although we do not address the consistency of the modeling used in the calculation for field and satellite data. In addition, light pollution in the city center of Erzincan and its surroundings was determined using data from SQM-LU and VIIRS, and the energy loss due to artificial lighting was calculated. To determine the effect of the change in zenith angle, SQM-LU measurements were made at distances of 5o between the zenith and the horizon at 4 points in the east, west, north, and south directions, while SQM-LU measurements were made at 45 points in the zenith direction. For the SQM measurements, the lowest (bright) and highest (dim) readings are 16.9 magnitude/arcsec2 and 20.30 magnitude/arcsec2, respectively, while according to the VIIRS satellite data they are 16.2 magnitude/arcsec2 and 18.9 magnitude/arcsec2, respectively. While the smallest value of the total luminous flux calculated for the city center of Erzincan and its surroundings (calculated from measurements in the zenith direction) is ~1.56 million lumens according to the SQM measurements, it is calculated to be ~5.98 million lumens according to the VIIRS satellite data. Taking into account the effect of 73% atmospheric transmittance and zenith angle dependence in the calculations, the total amount of luminous flux was calculated to be ~31.17 million lumens according to the SQM data and ~42.2 million lumens according to the VIIRS data. Considering that street lighting, billboards and outdoor lighting of buildings in the city are active for about 12 hours per day, the amount of wasted energy was calculated to be 112 219 kWh/month. A strong correlation was found between SQM and VIIRS values with R2 ≈0.71. © 2024 Gheorghe Asachi Technical University of Iasi, Romania. All rights reserved.
dc.identifier.doi10.30638/eemj.2024.205
dc.identifier.eissn1843-3707
dc.identifier.endpage2565
dc.identifier.issn1582-9596
dc.identifier.issue12
dc.identifier.scopus2-s2.0-86000554807
dc.identifier.startpage2555
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/11300
dc.identifier.volume23
dc.identifier.wosWOS:001421108600013
dc.language.isoen
dc.publisherGheorghe Asachi Technical University of Iasi, Romania
dc.relation.ispartofEnvironmental Engineering and Management Journal
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectcalculation of wasted energy amount
dc.subjectlight pollution
dc.subjectSQM
dc.subjectVIIRS
dc.titleESTIMATION OF ENERGY LOSS DUE TO LIGHT POLLUTION USING SATELLITE AND FIELD MEASUREMENT DATA: EXAMPLE OF ERZİNCAN CITY
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus1
rdl.citation.wos0
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)