Intrastromal Suturing Technique Compared With Interrupted Corneal Suturing Technique, Loose Suture and Knot Exposure: A Comparative Rabbit Study

ArticleAçık Erişim

Özet

Purpose: This study aimed to assess the effectiveness of an innovative intrastromal suturing technique in an experimental rabbit model, comparing it to standard interrupted suturing, loose suture, and suturing with knot exposure. Methods: Fourteen adult male New Zealand White rabbits were included in this study. Each rabbit underwent suturing in both eyes, divided into four groups based on suturing techniques. The novel intrastromal suturing technique involved burying the entire suture material within the corneal stroma. Corneal neovascularisation (CoNV) areas were evaluated by image analysis and immune cell densities by in vivo confocal microscopy (IVCM). Results: The intrastromal suturing group demonstrated significantly smaller CoNV areas at both 1 week and 1 month post-suturing compared to other interventional groups, indicating effective mitigation of CoNV development and progression. Moreover, this group exhibited lower immune cell densities in the superficial stromal layer and endothelial layer, suggesting a reduced inflammatory response. Both the loose suture and the knot exposure groups exhibited significant levels of CoNV and heightened immune cell densities. Conclusion: This experimental study demonstrated effectiveness of intrastromal suturing technique in limiting CoNV and immune cell infiltration, common contributors to graft rejection and complications. Furthermore, the study revealed that loose sutures and those with exposed knots are likely to cause more severe CoNV and inflammation, compared to the traditional interrupted suturing technique and intrastromal suturing. © The Author(s) 2025.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/11449Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1177/15533506251328456Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorOzkan, Kaan
dc.contributor.authorAydın, Bahri
dc.contributor.authorUcgul, Ahmet Yucel
dc.contributor.authorBayrakceken, Kemal
dc.contributor.authorOzmen, Mehmet Cuneyt
dc.contributor.authorAkata, Rustu Fikret
dc.date.accessioned2026-10-18T20:26:29.542082443Z
dc.date.available2026-10-18T20:26:29.542082443Z
dc.date.issued2025
dc.description.abstractPurpose: This study aimed to assess the effectiveness of an innovative intrastromal suturing technique in an experimental rabbit model, comparing it to standard interrupted suturing, loose suture, and suturing with knot exposure. Methods: Fourteen adult male New Zealand White rabbits were included in this study. Each rabbit underwent suturing in both eyes, divided into four groups based on suturing techniques. The novel intrastromal suturing technique involved burying the entire suture material within the corneal stroma. Corneal neovascularisation (CoNV) areas were evaluated by image analysis and immune cell densities by in vivo confocal microscopy (IVCM). Results: The intrastromal suturing group demonstrated significantly smaller CoNV areas at both 1 week and 1 month post-suturing compared to other interventional groups, indicating effective mitigation of CoNV development and progression. Moreover, this group exhibited lower immune cell densities in the superficial stromal layer and endothelial layer, suggesting a reduced inflammatory response. Both the loose suture and the knot exposure groups exhibited significant levels of CoNV and heightened immune cell densities. Conclusion: This experimental study demonstrated effectiveness of intrastromal suturing technique in limiting CoNV and immune cell infiltration, common contributors to graft rejection and complications. Furthermore, the study revealed that loose sutures and those with exposed knots are likely to cause more severe CoNV and inflammation, compared to the traditional interrupted suturing technique and intrastromal suturing. © The Author(s) 2025.
dc.identifier.doi10.1177/15533506251328456
dc.identifier.eissn1553-3514
dc.identifier.endpage333
dc.identifier.issn1553-3506
dc.identifier.issue4
dc.identifier.pmid40200392
dc.identifier.scopus2-s2.0-105002870858
dc.identifier.startpage325
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/11449
dc.identifier.volume32
dc.identifier.wosWOS:001464075200001
dc.language.isoen
dc.publisherSAGE Publications Inc.
dc.relation.ispartofSurgical Innovation
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectcorneal neovascularization
dc.subjectimmune cell density
dc.subjectintrastromal suturing
dc.subjectrabbit study
dc.subjectstandard interrupted suturing
dc.subjectAnimals
dc.subjectCornea
dc.subjectCorneal Stroma
dc.subjectMale
dc.subjectRabbits
dc.subjectSuture Techniques
dc.subjectSutures
dc.subjectadverse event
dc.subjectanimal
dc.subjectcomparative study
dc.subjectcornea neovascularization
dc.subjectcornea stroma
dc.subjectLeporidae
dc.subjectprevention and control
dc.subjectsurgery
dc.subjectsuture
dc.subjectsuture technique
dc.titleIntrastromal Suturing Technique Compared With Interrupted Corneal Suturing Technique, Loose Suture and Knot Exposure: A Comparative Rabbit Study
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus2
rdl.citation.wos2
rdl.departmentDepartment of Ophthalmology, School of Medicine, Erzincan Binali Yildirim University, Erzincan, Turkey.
rdl.oa.statusopen
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)