Normal umbilical artery doppler values in 18–22 week old fetuses with single umbilical artery

ArticleAçık Erişim

Özet

Umbilical cord with a single umbilical artery (SUA) can carry twice the blood volume of a three-vessel cord (TVC). So, the normal hemodynamics of the fetuses with SUA was different from those with TVC. Furthermore, structural abnormalities, fetal aneuploidy, and intrinsic growth retardation may be associated with the presence of a SUA. In order to evaluate these patients, intermittent doppler measurements have been suggested. From this point, we aimed to determine the CDUS flow parameters in SUA cases and to demonstrate that these flow parameters are different from the TVC parameters. Ultrasound (US) examinations were performed in the 18–22 weeks of gestation during routine fetal anatomy screening. Resistance index (RI), Pulsatility index (PI), and S/D: systole to diastole ratio values were measured. The samples were taken from the proximal, mid-portion, and distal of the umbilical cord. In addition to Doppler Ultrasound values, AC and estimated fetal weight (EFW) values were also recorded. The study included 167 pregnant women, 86 of whom were study group with SUA and 81 were control group with TVC. The measurements of RI, PI, and S/D at all three levels were significantly lower in the SUA group compared to the TVC group. The resistance in the UA of fetuses with SUA is lower than in fetuses with TVC. The resistance in the UA of fetuses with SUA decreases from the fetal end to the placental end. Knowing the normal values for fetuses with SUA might provide a better and more reliable Doppler Ultrasoundassessment. © 2023, The Author(s).

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/11819Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1038/s41598-023-37691-zYayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKazci, Omer
dc.contributor.authorAydin, Sonay
dc.contributor.authorFatihoglu, Erdem
dc.contributor.authorTokur, Oğuzhan
dc.contributor.authorBahadir, Suzan
dc.contributor.authorKaravas, Erdal
dc.contributor.authorKantarci, Mecit
dc.date.accessioned2026-10-18T20:26:48.921377297Z
dc.date.available2026-10-18T20:26:48.921377297Z
dc.date.issued2023
dc.description.abstractUmbilical cord with a single umbilical artery (SUA) can carry twice the blood volume of a three-vessel cord (TVC). So, the normal hemodynamics of the fetuses with SUA was different from those with TVC. Furthermore, structural abnormalities, fetal aneuploidy, and intrinsic growth retardation may be associated with the presence of a SUA. In order to evaluate these patients, intermittent doppler measurements have been suggested. From this point, we aimed to determine the CDUS flow parameters in SUA cases and to demonstrate that these flow parameters are different from the TVC parameters. Ultrasound (US) examinations were performed in the 18–22 weeks of gestation during routine fetal anatomy screening. Resistance index (RI), Pulsatility index (PI), and S/D: systole to diastole ratio values were measured. The samples were taken from the proximal, mid-portion, and distal of the umbilical cord. In addition to Doppler Ultrasound values, AC and estimated fetal weight (EFW) values were also recorded. The study included 167 pregnant women, 86 of whom were study group with SUA and 81 were control group with TVC. The measurements of RI, PI, and S/D at all three levels were significantly lower in the SUA group compared to the TVC group. The resistance in the UA of fetuses with SUA is lower than in fetuses with TVC. The resistance in the UA of fetuses with SUA decreases from the fetal end to the placental end. Knowing the normal values for fetuses with SUA might provide a better and more reliable Doppler Ultrasoundassessment. © 2023, The Author(s).
dc.identifier.doi10.1038/s41598-023-37691-z
dc.identifier.issn2045-2322
dc.identifier.issue1
dc.identifier.pmcidPMC10307771
dc.identifier.pmid37380720
dc.identifier.scopus2-s2.0-85163608201
dc.identifier.startpage10477
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/11819
dc.identifier.volume13
dc.identifier.wosWOS:001022873100011
dc.language.isoen
dc.publisherNature Research
dc.relation.ispartofScientific Reports
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCone-Rod Dystrophies
dc.subjectFemale
dc.subjectFetus
dc.subjectHumans
dc.subjectPlacenta
dc.subjectPregnancy
dc.subjectReference Values
dc.subjectSingle Umbilical Artery
dc.subjectUltrasonography, Doppler
dc.subjectUmbilical Arteries
dc.subjectcone rod dystrophy
dc.subjectdiagnostic imaging
dc.subjectDoppler ultrasonography
dc.subjecthuman
dc.subjectreference value
dc.subjectumbilical artery
dc.titleNormal umbilical artery doppler values in 18–22 week old fetuses with single umbilical artery
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus3
rdl.citation.wos2
rdl.departmentDepartment of Radiology, Erzincan University, Erzincan, Turkey.
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)