Bias-Aware Detection Limits, Calibration Transfer and Matched-Control Robustness Assessment in Dual-Parameter Photonic Refractive-Index and Temperature Sensing: A Coupled Interface-Mode Multilayer Case Study

ArticleAçık Erişim

Özet

Dual-parameter photonic sensors are usually reported through a nominal sensitivity and one detection limit, without stating which statistic that limit is or whether it survives transfer between devices. This computational study supplies that evaluation for one structure, a 36-layer one-dimensional multilayer read in transmission, whose Zak-phase-distinct TiO2/SiO2 photonic-crystal sections enclose a 600 nm analyte cavity and a 500 nm thermo-optic reference cavity, each carrying a 5 nm ITO/5 nm TiO2 nanolaminate insert. Two coupled interface resonances at 1517 and 1651 nm, with loaded Q of 232 and 208 and refractive-index (RI) sensitivities of 90.71 and 329.41 nm/RIU, are inverted by a bounded nonlinear calibration to (Formula presented.) RIU and (Formula presented.) (Formula presented.) ; the temperature channel reports the device temperature. Probability-of-detection limits at 1% false alarm and 95% detection are (Formula presented.) RIU and (Formula presented.) (Formula presented.) ; they are set by the calibration standards and the wavelength reference, not by the linewidth. Transferring one calibration between devices worsens them 81-fold and 203-fold; a three-point per-device correction removes 84–93% of that loss. A trivial control matched on wavelength, Q, transmission, thickness and RI sensitivity shows no topological robustness advantage. Applied to the design itself, the same evaluation shows that the modes are cavity-selected, that hyperbolicity brings no benefit, and that the nanolaminate-free stack is preferred. © 2026 by the authors.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/10273Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.3390/s26185955Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorErtay, Agah Oktay
dc.contributor.authorErtay, Muhammed Mustafa
dc.date.accessioned2026-10-18T20:25:30.982826407Z
dc.date.available2026-10-18T20:25:30.982826407Z
dc.date.issued2026
dc.description.abstractDual-parameter photonic sensors are usually reported through a nominal sensitivity and one detection limit, without stating which statistic that limit is or whether it survives transfer between devices. This computational study supplies that evaluation for one structure, a 36-layer one-dimensional multilayer read in transmission, whose Zak-phase-distinct TiO2/SiO2 photonic-crystal sections enclose a 600 nm analyte cavity and a 500 nm thermo-optic reference cavity, each carrying a 5 nm ITO/5 nm TiO2 nanolaminate insert. Two coupled interface resonances at 1517 and 1651 nm, with loaded Q of 232 and 208 and refractive-index (RI) sensitivities of 90.71 and 329.41 nm/RIU, are inverted by a bounded nonlinear calibration to (Formula presented.) RIU and (Formula presented.) (Formula presented.) ; the temperature channel reports the device temperature. Probability-of-detection limits at 1% false alarm and 95% detection are (Formula presented.) RIU and (Formula presented.) (Formula presented.) ; they are set by the calibration standards and the wavelength reference, not by the linewidth. Transferring one calibration between devices worsens them 81-fold and 203-fold; a three-point per-device correction removes 84–93% of that loss. A trivial control matched on wavelength, Q, transmission, thickness and RI sensitivity shows no topological robustness advantage. Applied to the design itself, the same evaluation shows that the modes are cavity-selected, that hyperbolicity brings no benefit, and that the nanolaminate-free stack is preferred. © 2026 by the authors.
dc.identifier.doi10.3390/s26185955
dc.identifier.eissn1424-8220
dc.identifier.issn1424-8220
dc.identifier.issue18
dc.identifier.pmcidPMC13611379
dc.identifier.pmid42817495
dc.identifier.scopus2-s2.0-105052375400
dc.identifier.startpage5955
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/10273
dc.identifier.volume26
dc.identifier.wosWOS:001891449600001
dc.language.isoen
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.relation.ispartofSensors
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectbias-aware detection limit
dc.subjectcalibration transfer
dc.subjectdual-parameter sensing
dc.subjectfabrication tolerance
dc.subjectmatched controls
dc.subjectnonlinear parameter retrieval
dc.subjectoptical sensors
dc.subjectprobability of detection
dc.subjectrefractive-index sensing
dc.subjectthermo-optic sensing
dc.subjectCalibration
dc.subjectMultilayers
dc.subjectNonlinear optics
dc.subjectOne dimensional
dc.subjectPhotonic crystals
dc.subjectPhotonic devices
dc.subjectPhotonics
dc.subjectSignal detection
dc.subjectTemperature sensors
dc.subjectsilicon dioxide
dc.subjectDetection limits
dc.subjectFabrication tolerances
dc.subjectNon-linear parameters
dc.subjectOptical-
dc.subjectParameter retrieval
dc.subjectRefractive index sensing
dc.subjectThermooptics
dc.subjectarticle
dc.subjectcase study
dc.subjectcontrolled study
dc.titleBias-Aware Detection Limits, Calibration Transfer and Matched-Control Robustness Assessment in Dual-Parameter Photonic Refractive-Index and Temperature Sensing: A Coupled Interface-Mode Multilayer Case Study
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus0
rdl.citation.wos0
rdl.departmentFaculty of Engineering and Architecture, Department of Electrical and Electronics Engineering, Erzincan Binali Yildirim University, Yalnizbag Campus, Erzincan 24002, Türkiye.
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)