Ensuring pharmaceutical safety: Highthroughput LC-MS/MS method for plastic additive detection
Özet
Extractables and Leachables studies require highly reliable and sensitive analytical methods to ensure pharmaceutical product safety. Plastic additives are widely used during production to improve the physicochemical properties of polymeric products. However, these additives may constitute a potential toxicological risk by contaminating active pharmaceutical ingredients and pharmaceutical preparations. In this study, a short-term, sensitive, accurate, and reliable LC-MS/MS method was developed for the analysis of 15 plastic additives defined in the European Pharmacopoeia and validated in accordance with the ICH Q2(R2) guideline. An electrospray ionization source was used for the analyses in both negative and positive modes. Chromatographic separation was carried out using a reverse-phase phenyl C18 column and a mixture of methanol and ultrapure water containing 5 mM ammonium acetate as the mobile phase by the gradient elution method. As a result of method optimization, the flow rate and total analysis time were determined to be 0.7 mL/min and 15 min, respectively. Diphenyl phthalate was chosen as the internal standard. The LLOQ values of plastic additives were generally determined as 50 ng/mL (150 ng/mL for oleamide). The reliability of the method was verified by intraday/interday precision and accuracy analyses. Both extractable and leachable studies were performed using the developed method. It was effectively used to detect plastic additive contamination in pharmaceutical products such as bromobutyl stoppers, LDPE containers, disposable eye drop packaging, and polypropylene bags. The developed LC-MS/MS method was successfully applied to the analysis of pharmaceutical formulations containing 1.4% polyvinyl alcohol and 0.6% povidone, sodium hyaluronate, salbutamol sulfate, and 0.9% isotonic sodium chloride. © 2025 American Pharmacists Association.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Demircioğlu, İbrahim Hakkı | |
| dc.contributor.author | Dalkılıç, Oğuzhan | |
| dc.contributor.author | Çelik, Saffet | |
| dc.contributor.author | Akman, Tugrul Cagri | |
| dc.contributor.author | Kılıç, Hamdullah | |
| dc.contributor.author | Kandemir, Levent | |
| dc.contributor.author | Atila, Alptuğ | |
| dc.date.accessioned | 2026-10-18T20:25:39.529076787Z | |
| dc.date.available | 2026-10-18T20:25:39.529076787Z | |
| dc.date.issued | 2026 | |
| dc.description.abstract | Extractables and Leachables studies require highly reliable and sensitive analytical methods to ensure pharmaceutical product safety. Plastic additives are widely used during production to improve the physicochemical properties of polymeric products. However, these additives may constitute a potential toxicological risk by contaminating active pharmaceutical ingredients and pharmaceutical preparations. In this study, a short-term, sensitive, accurate, and reliable LC-MS/MS method was developed for the analysis of 15 plastic additives defined in the European Pharmacopoeia and validated in accordance with the ICH Q2(R2) guideline. An electrospray ionization source was used for the analyses in both negative and positive modes. Chromatographic separation was carried out using a reverse-phase phenyl C18 column and a mixture of methanol and ultrapure water containing 5 mM ammonium acetate as the mobile phase by the gradient elution method. As a result of method optimization, the flow rate and total analysis time were determined to be 0.7 mL/min and 15 min, respectively. Diphenyl phthalate was chosen as the internal standard. The LLOQ values of plastic additives were generally determined as 50 ng/mL (150 ng/mL for oleamide). The reliability of the method was verified by intraday/interday precision and accuracy analyses. Both extractable and leachable studies were performed using the developed method. It was effectively used to detect plastic additive contamination in pharmaceutical products such as bromobutyl stoppers, LDPE containers, disposable eye drop packaging, and polypropylene bags. The developed LC-MS/MS method was successfully applied to the analysis of pharmaceutical formulations containing 1.4% polyvinyl alcohol and 0.6% povidone, sodium hyaluronate, salbutamol sulfate, and 0.9% isotonic sodium chloride. © 2025 American Pharmacists Association. | |
| dc.description.sponsorship | For their valuable support in the realization of this study; We would like to express our sincere gratitude to T\u00DCB\u0130TAK (B\u0130DEB 2244-Industrial Doctoral Scholarship Program and 2250-Graduate Scholarships Performance Program, Project No: 119C134), Polifarma Pharmaceutical Industry and Trade Inc., Atat\u00FCrk University BAP Coordinatorship (Project No: TDK-2022-10732) and Eastern Anatolia High Technology Application and Research Center (DAYTAM) for providing the research infrastructure. | |
| dc.identifier.doi | 10.1016/j.xphs.2025.104135 | |
| dc.identifier.eissn | 1520-6017 | |
| dc.identifier.issn | 0022-3549 | |
| dc.identifier.issue | 2 | |
| dc.identifier.pmid | 41412534 | |
| dc.identifier.scopus | 2-s2.0-105025653718 | |
| dc.identifier.startpage | 104135 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/10442 | |
| dc.identifier.volume | 115 | |
| dc.identifier.wos | WOS:001650082600001 | |
| dc.language.iso | en | |
| dc.publisher | Elsevier B.V. | |
| dc.relation.ispartof | Journal of Pharmaceutical Sciences | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Extractables & leachables | |
| dc.subject | LC-MS/MS | |
| dc.subject | Packaging materials | |
| dc.subject | Pharmaceuticals | |
| dc.subject | Plastic additives | |
| dc.subject | Validation | |
| dc.subject | Chromatography, Liquid | |
| dc.subject | Drug Contamination | |
| dc.subject | Liquid Chromatography-Mass Spectrometry | |
| dc.subject | Pharmaceutical Preparations | |
| dc.subject | Plastics | |
| dc.subject | Reproducibility of Results | |
| dc.subject | Tandem Mass Spectrometry | |
| dc.subject | 3 (3,5 di tert butyl 4 hydroxyphenyl)propionic acid octadecyl ester | |
| dc.subject | ammonium acetate | |
| dc.subject | butyryl trihexyl citrate | |
| dc.subject | cresol | |
| dc.subject | diphenyl pthalate | |
| dc.subject | dryex | |
| dc.subject | hostanox | |
| dc.subject | novaqua | |
| dc.subject | pentaerythritol tetrakis[3 (3,5 di tert butyl 4 hydroxyphenyl)propionate] | |
| dc.subject | polifleks | |
| dc.subject | polypropylene | |
| dc.subject | polyvinyl alcohol | |
| dc.subject | ronkotol | |
| dc.subject | stearic acid | |
| dc.subject | tetrahydrofuran | |
| dc.subject | trimellitic acid tris(2 ethylhexyl) ester | |
| dc.subject | unclassified drug | |
| dc.title | Ensuring pharmaceutical safety: Highthroughput LC-MS/MS method for plastic additive detection | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 0 | |
| rdl.citation.wos | 0 | |
| rdl.department | Department of Analytical Chemistry, Faculty of Pharmacy, Erzincan Binali Yildirim University, Erzincan, 24100, Turkiye. | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.source.index | PUBMED | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |