Correlation of Diffusion weighted MR Imaging and ADC Values of Hepatic Metastasis of Gastrointestinal Stromal and Gastroenteropancreatic Neuroendocrine Tumors
Özet
Background: DWI and ADC-mapping was performed to analyze hepatic metastasis of GIST, GEP-NET. Objective: The objective of this study is to present hepatic metastasis of GIST and GEP-NET with Diffusion weighted MR imaging(DWI) and the Apparent diffusion coefficients (ADC) values of masses. Methods: 18 GIST patients and 8 GEP-NET patients were examined retrospectively. 11 males and 6 females were present in GIST group, 7 males to 5 females were involved in GEP-NET group. 18 primary GIST and 10 hepatic metastasis of GIST, 8 original GEP-NET and 19 hepatic metastasis of GEP-NET; total 55 GIST and GEP-NET masses were analysed by ADC mapping. MR images were acquired by 1,5 T MR units (32 mT/min gradient strength-Achieva; Philips Healthcare, Best, Netherlands and 32 channel GE Signa GE-Wisconsin-USA); by using a 4-8 channel standard phased-array torso XL coil, all images were evaluated by an Abdominal MRI experienced radiologist. DWI was performed in the transverse plane by using spin-echo-planar imaging sequence. Results: No statistical differences were observed between GIST and GEP-NET patients according to age and gender variations. No significant statistical differences were observed according to the diameters and ADC values of GIST and GEP-NET patients. A significant statistical difference was observed between GIST and GEP-NET groups in terms of size of liver metastasis which was significantly higher in GIST patients. All three groups (GIST_Hep. MET, GEP-NET_Liver_Met and normal) were statistically differed according to ADC values. With the ROC curve analysis: Hepatic metastasis of GIST(n=10) and normal liver (n:47) had cut-off value for ADC: 0.925 under AUC: 0.939 with regard to ADC values and regarded 89.4% Sensitivity, 100% Specificity, 100% PPV and 66.7% PPV. ROC curve of GEP NET_ Hepatic metastasis (n=19) group and normal liver (n:47) group presented cut-off value for ADC: 0.860 under AUC: 0.967 correlated to ADC values with 93.6% sensitivity, 89.5% specificity, 95.7% PPV and 85% PPV. Conclusion: High cellular tumors resulted from liver metastasis of GIST and GEP-NET’s, and a positive correlation was observed between ADC values and cellularity/differentiation ratios of metastatic masses. © 2024 The Author(s). Published by Bentham Science Publisher.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Aydın, Hasan | |
| dc.contributor.author | Metin, Melike Ruşen | |
| dc.contributor.author | Kızılgöz, Volkan | |
| dc.date.accessioned | 2026-10-18T20:26:53.676612314Z | |
| dc.date.available | 2026-10-18T20:26:53.676612314Z | |
| dc.date.issued | 2024 | |
| dc.description.abstract | Background: DWI and ADC-mapping was performed to analyze hepatic metastasis of GIST, GEP-NET. Objective: The objective of this study is to present hepatic metastasis of GIST and GEP-NET with Diffusion weighted MR imaging(DWI) and the Apparent diffusion coefficients (ADC) values of masses. Methods: 18 GIST patients and 8 GEP-NET patients were examined retrospectively. 11 males and 6 females were present in GIST group, 7 males to 5 females were involved in GEP-NET group. 18 primary GIST and 10 hepatic metastasis of GIST, 8 original GEP-NET and 19 hepatic metastasis of GEP-NET; total 55 GIST and GEP-NET masses were analysed by ADC mapping. MR images were acquired by 1,5 T MR units (32 mT/min gradient strength-Achieva; Philips Healthcare, Best, Netherlands and 32 channel GE Signa GE-Wisconsin-USA); by using a 4-8 channel standard phased-array torso XL coil, all images were evaluated by an Abdominal MRI experienced radiologist. DWI was performed in the transverse plane by using spin-echo-planar imaging sequence. Results: No statistical differences were observed between GIST and GEP-NET patients according to age and gender variations. No significant statistical differences were observed according to the diameters and ADC values of GIST and GEP-NET patients. A significant statistical difference was observed between GIST and GEP-NET groups in terms of size of liver metastasis which was significantly higher in GIST patients. All three groups (GIST_Hep. MET, GEP-NET_Liver_Met and normal) were statistically differed according to ADC values. With the ROC curve analysis: Hepatic metastasis of GIST(n=10) and normal liver (n:47) had cut-off value for ADC: 0.925 under AUC: 0.939 with regard to ADC values and regarded 89.4% Sensitivity, 100% Specificity, 100% PPV and 66.7% PPV. ROC curve of GEP NET_ Hepatic metastasis (n=19) group and normal liver (n:47) group presented cut-off value for ADC: 0.860 under AUC: 0.967 correlated to ADC values with 93.6% sensitivity, 89.5% specificity, 95.7% PPV and 85% PPV. Conclusion: High cellular tumors resulted from liver metastasis of GIST and GEP-NET’s, and a positive correlation was observed between ADC values and cellularity/differentiation ratios of metastatic masses. © 2024 The Author(s). Published by Bentham Science Publisher. | |
| dc.description.sponsorship | Declared none. | |
| dc.identifier.doi | 10.2174/1573405620666230522151427 | |
| dc.identifier.eissn | 1875-6603 | |
| dc.identifier.issn | 1573-4056 | |
| dc.identifier.pmid | 37272460 | |
| dc.identifier.scopus | 2-s2.0-85178310374 | |
| dc.identifier.startpage | e220523217207 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/11914 | |
| dc.identifier.volume | 20 | |
| dc.identifier.wos | WOS:001307790600001 | |
| dc.language.iso | en | |
| dc.publisher | Bentham Science Publishers | |
| dc.relation.ispartof | Current Medical Imaging | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Diffusion | |
| dc.subject | GIST | |
| dc.subject | Hepatic | |
| dc.subject | Imaging | |
| dc.subject | Metastasis | |
| dc.subject | MR | |
| dc.subject | Adult | |
| dc.subject | Aged | |
| dc.subject | Diffusion Magnetic Resonance Imaging | |
| dc.subject | Female | |
| dc.subject | Gastrointestinal Neoplasms | |
| dc.subject | Gastrointestinal Stromal Tumors | |
| dc.subject | Humans | |
| dc.subject | Liver Neoplasms | |
| dc.subject | Male | |
| dc.subject | Middle Aged | |
| dc.subject | Neuroendocrine Tumors | |
| dc.subject | Pancreatic Neoplasms | |
| dc.subject | Reproducibility of Results | |
| dc.subject | Retrospective Studies | |
| dc.subject | Sensitivity and Specificity | |
| dc.subject | Diffusion tensor imaging | |
| dc.subject | Apparent diffusion coefficient | |
| dc.subject | Coefficient mapping | |
| dc.subject | Coefficient values | |
| dc.subject | Liver metastasis | |
| dc.subject | MR imaging | |
| dc.subject | Statistical differences | |
| dc.subject | area under the curve | |
| dc.subject | Article | |
| dc.title | Correlation of Diffusion weighted MR Imaging and ADC Values of Hepatic Metastasis of Gastrointestinal Stromal and Gastroenteropancreatic Neuroendocrine Tumors | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 0 | |
| rdl.citation.wos | 0 | |
| rdl.oa.status | gold | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |
