Correlation of Diffusion weighted MR Imaging and ADC Values of Hepatic Metastasis of Gastrointestinal Stromal and Gastroenteropancreatic Neuroendocrine Tumors

ArticleAçık Erişim

Özet

Background: DWI and ADC-mapping was performed to analyze hepatic metastasis of GIST, GEP-NET. Objective: The objective of this study is to present hepatic metastasis of GIST and GEP-NET with Diffusion weighted MR imaging(DWI) and the Apparent diffusion coefficients (ADC) values of masses. Methods: 18 GIST patients and 8 GEP-NET patients were examined retrospectively. 11 males and 6 females were present in GIST group, 7 males to 5 females were involved in GEP-NET group. 18 primary GIST and 10 hepatic metastasis of GIST, 8 original GEP-NET and 19 hepatic metastasis of GEP-NET; total 55 GIST and GEP-NET masses were analysed by ADC mapping. MR images were acquired by 1,5 T MR units (32 mT/min gradient strength-Achieva; Philips Healthcare, Best, Netherlands and 32 channel GE Signa GE-Wisconsin-USA); by using a 4-8 channel standard phased-array torso XL coil, all images were evaluated by an Abdominal MRI experienced radiologist. DWI was performed in the transverse plane by using spin-echo-planar imaging sequence. Results: No statistical differences were observed between GIST and GEP-NET patients according to age and gender variations. No significant statistical differences were observed according to the diameters and ADC values of GIST and GEP-NET patients. A significant statistical difference was observed between GIST and GEP-NET groups in terms of size of liver metastasis which was significantly higher in GIST patients. All three groups (GIST_Hep. MET, GEP-NET_Liver_Met and normal) were statistically differed according to ADC values. With the ROC curve analysis: Hepatic metastasis of GIST(n=10) and normal liver (n:47) had cut-off value for ADC: 0.925 under AUC: 0.939 with regard to ADC values and regarded 89.4% Sensitivity, 100% Specificity, 100% PPV and 66.7% PPV. ROC curve of GEP NET_ Hepatic metastasis (n=19) group and normal liver (n:47) group presented cut-off value for ADC: 0.860 under AUC: 0.967 correlated to ADC values with 93.6% sensitivity, 89.5% specificity, 95.7% PPV and 85% PPV. Conclusion: High cellular tumors resulted from liver metastasis of GIST and GEP-NET’s, and a positive correlation was observed between ADC values and cellularity/differentiation ratios of metastatic masses. © 2024 The Author(s). Published by Bentham Science Publisher.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/11914Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAydın, Hasan
dc.contributor.authorMetin, Melike Ruşen
dc.contributor.authorKızılgöz, Volkan
dc.date.accessioned2026-10-18T20:26:53.676612314Z
dc.date.available2026-10-18T20:26:53.676612314Z
dc.date.issued2024
dc.description.abstractBackground: DWI and ADC-mapping was performed to analyze hepatic metastasis of GIST, GEP-NET. Objective: The objective of this study is to present hepatic metastasis of GIST and GEP-NET with Diffusion weighted MR imaging(DWI) and the Apparent diffusion coefficients (ADC) values of masses. Methods: 18 GIST patients and 8 GEP-NET patients were examined retrospectively. 11 males and 6 females were present in GIST group, 7 males to 5 females were involved in GEP-NET group. 18 primary GIST and 10 hepatic metastasis of GIST, 8 original GEP-NET and 19 hepatic metastasis of GEP-NET; total 55 GIST and GEP-NET masses were analysed by ADC mapping. MR images were acquired by 1,5 T MR units (32 mT/min gradient strength-Achieva; Philips Healthcare, Best, Netherlands and 32 channel GE Signa GE-Wisconsin-USA); by using a 4-8 channel standard phased-array torso XL coil, all images were evaluated by an Abdominal MRI experienced radiologist. DWI was performed in the transverse plane by using spin-echo-planar imaging sequence. Results: No statistical differences were observed between GIST and GEP-NET patients according to age and gender variations. No significant statistical differences were observed according to the diameters and ADC values of GIST and GEP-NET patients. A significant statistical difference was observed between GIST and GEP-NET groups in terms of size of liver metastasis which was significantly higher in GIST patients. All three groups (GIST_Hep. MET, GEP-NET_Liver_Met and normal) were statistically differed according to ADC values. With the ROC curve analysis: Hepatic metastasis of GIST(n=10) and normal liver (n:47) had cut-off value for ADC: 0.925 under AUC: 0.939 with regard to ADC values and regarded 89.4% Sensitivity, 100% Specificity, 100% PPV and 66.7% PPV. ROC curve of GEP NET_ Hepatic metastasis (n=19) group and normal liver (n:47) group presented cut-off value for ADC: 0.860 under AUC: 0.967 correlated to ADC values with 93.6% sensitivity, 89.5% specificity, 95.7% PPV and 85% PPV. Conclusion: High cellular tumors resulted from liver metastasis of GIST and GEP-NET’s, and a positive correlation was observed between ADC values and cellularity/differentiation ratios of metastatic masses. © 2024 The Author(s). Published by Bentham Science Publisher.
dc.description.sponsorshipDeclared none.
dc.identifier.doi10.2174/1573405620666230522151427
dc.identifier.eissn1875-6603
dc.identifier.issn1573-4056
dc.identifier.pmid37272460
dc.identifier.scopus2-s2.0-85178310374
dc.identifier.startpagee220523217207
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/11914
dc.identifier.volume20
dc.identifier.wosWOS:001307790600001
dc.language.isoen
dc.publisherBentham Science Publishers
dc.relation.ispartofCurrent Medical Imaging
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectDiffusion
dc.subjectGIST
dc.subjectHepatic
dc.subjectImaging
dc.subjectMetastasis
dc.subjectMR
dc.subjectAdult
dc.subjectAged
dc.subjectDiffusion Magnetic Resonance Imaging
dc.subjectFemale
dc.subjectGastrointestinal Neoplasms
dc.subjectGastrointestinal Stromal Tumors
dc.subjectHumans
dc.subjectLiver Neoplasms
dc.subjectMale
dc.subjectMiddle Aged
dc.subjectNeuroendocrine Tumors
dc.subjectPancreatic Neoplasms
dc.subjectReproducibility of Results
dc.subjectRetrospective Studies
dc.subjectSensitivity and Specificity
dc.subjectDiffusion tensor imaging
dc.subjectApparent diffusion coefficient
dc.subjectCoefficient mapping
dc.subjectCoefficient values
dc.subjectLiver metastasis
dc.subjectMR imaging
dc.subjectStatistical differences
dc.subjectarea under the curve
dc.subjectArticle
dc.titleCorrelation of Diffusion weighted MR Imaging and ADC Values of Hepatic Metastasis of Gastrointestinal Stromal and Gastroenteropancreatic Neuroendocrine Tumors
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus0
rdl.citation.wos0
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)