The best anti-HCV S/Co values for reflecting HCV infection in a university hospital in the eastern part of Turkey

ArticleAçık Erişim

Özet

Introduction: The measurement of hepatitis C virus (HCV) RNA is a test that requires high cost, advanced technique, and qualified personnel. Diagnosis and treatment of patients may be delayed due to the high rate of false-positive results. This study aims to predict true antibody positivity and viremia by determining the most appropriate anti-HCV signal-to-cutoff (S/Co) value reflecting HCV infection. Methodology: The presence of anti-HCV antibodies and HCV RNA levels were examined in 72341 people who applied to the Mengücek Gazi Training and Research Hospital between January 2018 and December 2020. The anti-HCV levels were determined by using the Abbot Architect i2000 SR device (Abbot Diagnostics, Chicago, IL, USA). The levels of HCV RNA were determined in the COBAS AmpliPrep/COBAS, TaqMan 48 (Roche, Diagnostics, Pleasanton, USA) devices using serum samples from patients. Our study is a retrospective and methodological study. Results: Of the 150 patients with anti-HCV antibodies, 50 (33.3%) were HCV RNA positive, and 100 (66.7%) were HCV RNA negative. Anti-HCV levels of HCV RNA-positive patients were statistically higher than HCV RNA-negative patients. The most appropriate anti-HCV S/Co value for diagnosing hepatitis C patients was 15.4. The sensitivity of this value was 72%, specificity 88%, positive predictive value (PPV) 73.5%, and negative predictive value (NPV) 86.1%. Receiver operating characteristic (ROC) curve was significantly higher than 0.5 (95% confidence interval 0.938-0.827). Conclusions: Correct approaches can be applied in the diagnosis of HCV infection using the anti-HCV S/Co value found in our study. © 2024 Dabanlioǧlu et al.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/12007Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.3855/jidc.18105Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorDabanlioǧlu, Bülent
dc.contributor.authorYilmaz, Aysun
dc.contributor.authorAkyüz, Sümeyye
dc.contributor.authorGülhan, Bariş
dc.date.accessioned2026-10-18T20:26:58.211003592Z
dc.date.available2026-10-18T20:26:58.211003592Z
dc.date.issued2024
dc.description.abstractIntroduction: The measurement of hepatitis C virus (HCV) RNA is a test that requires high cost, advanced technique, and qualified personnel. Diagnosis and treatment of patients may be delayed due to the high rate of false-positive results. This study aims to predict true antibody positivity and viremia by determining the most appropriate anti-HCV signal-to-cutoff (S/Co) value reflecting HCV infection. Methodology: The presence of anti-HCV antibodies and HCV RNA levels were examined in 72341 people who applied to the Mengücek Gazi Training and Research Hospital between January 2018 and December 2020. The anti-HCV levels were determined by using the Abbot Architect i2000 SR device (Abbot Diagnostics, Chicago, IL, USA). The levels of HCV RNA were determined in the COBAS AmpliPrep/COBAS, TaqMan 48 (Roche, Diagnostics, Pleasanton, USA) devices using serum samples from patients. Our study is a retrospective and methodological study. Results: Of the 150 patients with anti-HCV antibodies, 50 (33.3%) were HCV RNA positive, and 100 (66.7%) were HCV RNA negative. Anti-HCV levels of HCV RNA-positive patients were statistically higher than HCV RNA-negative patients. The most appropriate anti-HCV S/Co value for diagnosing hepatitis C patients was 15.4. The sensitivity of this value was 72%, specificity 88%, positive predictive value (PPV) 73.5%, and negative predictive value (NPV) 86.1%. Receiver operating characteristic (ROC) curve was significantly higher than 0.5 (95% confidence interval 0.938-0.827). Conclusions: Correct approaches can be applied in the diagnosis of HCV infection using the anti-HCV S/Co value found in our study. © 2024 Dabanlioǧlu et al.
dc.identifier.doi10.3855/jidc.18105
dc.identifier.endpage135
dc.identifier.issn2036-6590
dc.identifier.issue1
dc.identifier.pmid38377100
dc.identifier.scopus2-s2.0-85185718387
dc.identifier.startpage131
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/12007
dc.identifier.volume18
dc.identifier.wosWOS:001171532700002
dc.language.isoen
dc.publisherJournal of Infection in Developing Countries
dc.relation.ispartofJournal of Infection in Developing Countries
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectanti-HCV
dc.subjectHCV RNA
dc.subjectS/Co
dc.subjectHepacivirus
dc.subjectHepatitis C
dc.subjectHepatitis C Antibodies
dc.subjectHospitals
dc.subjectHumans
dc.subjectRetrospective Studies
dc.subjectRNA, Viral
dc.subjectSensitivity and Specificity
dc.subjectTurkey
dc.subjectadult
dc.subjectaged
dc.subjectArticle
dc.subjectchemiluminescent microparticle immunoassay
dc.subjectfalse positive result
dc.subjectfemale
dc.subjectHepatitis C virus
dc.subjecthuman
dc.subjectmajor clinical study
dc.subjectmale
dc.subjectpredictive value
dc.subjectreal time polymerase chain reaction
dc.subjectreceiver operating characteristic
dc.subjectretrospective study
dc.subjectuniversity hospital
dc.subjectviremia
dc.subjectarchitect
dc.subjectdiagnosis
dc.titleThe best anti-HCV S/Co values for reflecting HCV infection in a university hospital in the eastern part of Turkey
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus1
rdl.citation.wos2
rdl.departmentErzincan Binali Yıldırım University, Faculty of Medicine, Department of Medical Microbiology, Erzincan, Turkey.
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)