Variable determined for optimization of alternating energy on the load by the adaptive Taguchi method

ArticleAçık Erişim

Özet

It is important to find the optimum point in terms of energy quality in the studies for electrical energy conversions with the converter and inverter circuits. In such studies, the authors tried to find the optimum operating point by using control systems such as PID and Fuzzy Logic in closed-loop controls. When a large number of variables are involved in finding the optimum point, closed-loop control methods such as these may be insufficient to find the optimum point. Therefore, in this study, the Adaptive Taguchi Method (ATM) with the maximum-minimum value is used for the estimation of variables providing the optimum point for energy quality by using it in a multilevel inverter with a double DC-DC converter. While in traditional Taguchi Methods, dependent variables predict the results by revealing their effects on independent variables, in ATM, besides the effects of the independent variables, the effects of different dependent variables on each other are also estimated. First, the system to which the ATM will be applied is introduced. Then, the principles of applying the ATM are explained. In the known Taguchi method, variable values to be found with 34 = 81 trials, variables are estimated with 27 trials, while the values of two different dependent variables in the system can be found with 54 trials instead of 2×34= 2×81 trials. The resulting values to be estimated with the proposed ATM method are estimated with 27 trials instead of 2×81 or 54 trials. Finally, the observation results to be used for estimation are analyzed and evaluated. By trying the prediction results, it is seen that the proposed system is quite effective because the estimated result value that is %3.71 in the experiments gives a lesser distortion value than the values used for prediction. © 2022 University of Kuwait. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/12651Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.36909/jer.12657Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorCan, Erol
dc.date.accessioned2026-10-18T20:27:31.737117718Z
dc.date.available2026-10-18T20:27:31.737117718Z
dc.date.issued2022
dc.description.abstractIt is important to find the optimum point in terms of energy quality in the studies for electrical energy conversions with the converter and inverter circuits. In such studies, the authors tried to find the optimum operating point by using control systems such as PID and Fuzzy Logic in closed-loop controls. When a large number of variables are involved in finding the optimum point, closed-loop control methods such as these may be insufficient to find the optimum point. Therefore, in this study, the Adaptive Taguchi Method (ATM) with the maximum-minimum value is used for the estimation of variables providing the optimum point for energy quality by using it in a multilevel inverter with a double DC-DC converter. While in traditional Taguchi Methods, dependent variables predict the results by revealing their effects on independent variables, in ATM, besides the effects of the independent variables, the effects of different dependent variables on each other are also estimated. First, the system to which the ATM will be applied is introduced. Then, the principles of applying the ATM are explained. In the known Taguchi method, variable values to be found with 34 = 81 trials, variables are estimated with 27 trials, while the values of two different dependent variables in the system can be found with 54 trials instead of 2×34= 2×81 trials. The resulting values to be estimated with the proposed ATM method are estimated with 27 trials instead of 2×81 or 54 trials. Finally, the observation results to be used for estimation are analyzed and evaluated. By trying the prediction results, it is seen that the proposed system is quite effective because the estimated result value that is %3.71 in the experiments gives a lesser distortion value than the values used for prediction. © 2022 University of Kuwait. All rights reserved.
dc.identifier.doi10.36909/jer.12657
dc.identifier.eissn2307-1885
dc.identifier.endpage335
dc.identifier.issn2307-1885
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85142222381
dc.identifier.startpage316
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/12651
dc.identifier.volume10
dc.identifier.wosWOS:000891783100018
dc.language.isoen
dc.publisherUniversity of Kuwait
dc.relation.ispartofJournal of Engineering Research (Kuwait)
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectATM
dc.subjectFuzzy Logic
dc.subjectOptimum point
dc.subjectPrediction results
dc.titleVariable determined for optimization of alternating energy on the load by the adaptive Taguchi method
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus4
rdl.citation.wos2
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)