Multi-objective optimization of a mini channeled cold plate for using thermal management of a Li-Ion battery

ArticleAçık Erişim

Özet

Mini channeled cold plates (MCCP) are an impressive choice for electric vehicles with a liquid-based thermal management system to keep the battery temperature within the desired range and to achieve a homogeneous temperature distribution. This paper came up with an optimum solution for maximum battery temperature (MBT), maximum temperature difference on the battery surface (MTD) and pressure drops in the channels (ΔP), which are vital parameters. Multi-objective optimization of geometric parameters and coolant flow rate of a designed MCCP which is experimentally investigated is carried out using the Desirability Function Approach. Firstly, the design of experiments (DoE) is generated using response surface method after determining the input variables and their levels. Then, each sample of DoE are modeled and analyzed numerically. Furthermore, the regression equations of the objective functions (MBT, MTD and ΔP) depending on the design parameters are developed and their variance analyzes are performed. Prediction accuracies of model equations developed for MBT, MTD and ΔP are 97.75%, 95.49% and 97.15%, respectively. As a result, optimum values of design variables, namely channel width (mm), distance between branches (mm), channel depth (mm), number of crossovers in branches and coolant flow rate (l/min) are 5, 5, 10, 13 and 0.7061, respectively. © 2022

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/12731Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKalkan, Orhan
dc.contributor.authorCelen, Ali
dc.contributor.authorBakirci, Kadir
dc.date.accessioned2026-10-18T20:27:35.867021051Z
dc.date.available2026-10-18T20:27:35.867021051Z
dc.date.issued2022
dc.description.abstractMini channeled cold plates (MCCP) are an impressive choice for electric vehicles with a liquid-based thermal management system to keep the battery temperature within the desired range and to achieve a homogeneous temperature distribution. This paper came up with an optimum solution for maximum battery temperature (MBT), maximum temperature difference on the battery surface (MTD) and pressure drops in the channels (ΔP), which are vital parameters. Multi-objective optimization of geometric parameters and coolant flow rate of a designed MCCP which is experimentally investigated is carried out using the Desirability Function Approach. Firstly, the design of experiments (DoE) is generated using response surface method after determining the input variables and their levels. Then, each sample of DoE are modeled and analyzed numerically. Furthermore, the regression equations of the objective functions (MBT, MTD and ΔP) depending on the design parameters are developed and their variance analyzes are performed. Prediction accuracies of model equations developed for MBT, MTD and ΔP are 97.75%, 95.49% and 97.15%, respectively. As a result, optimum values of design variables, namely channel width (mm), distance between branches (mm), channel depth (mm), number of crossovers in branches and coolant flow rate (l/min) are 5, 5, 10, 13 and 0.7061, respectively. © 2022
dc.description.sponsorshipThis study was carried out with the support of Erzincan Binali Yıldırım University Research Fund , Project Number: FBA-2019-657 .
dc.identifier.doi10.1016/j.energy.2022.123949
dc.identifier.eissn1873-6785
dc.identifier.issn0360-5442
dc.identifier.scopus2-s2.0-85128221061
dc.identifier.startpage123949
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/12731
dc.identifier.volume251
dc.identifier.wosWOS:000798562800009
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofEnergy
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBattery thermal management
dc.subjectCold plate
dc.subjectLi-ion battery
dc.subjectMini channel
dc.subjectOptimization
dc.subjectBattery management systems
dc.subjectCoolants
dc.subjectDesign of experiments
dc.subjectMultiobjective optimization
dc.subjectTemperature control
dc.subjectThermal management (electronics)
dc.subjectBattery temperature
dc.subjectBattery thermal managements
dc.subjectCold plates
dc.subjectCoolant flowrate
dc.subjectMini-channels
dc.subjectMulti-objectives optimization
dc.subjectOptimisations
dc.subjectOptimum solution
dc.subjectThermal
dc.subjectThermal management systems
dc.subjectenergy management
dc.subjectfuel cell
dc.subjectregression analysis
dc.subjectLithium-ion batteries
dc.titleMulti-objective optimization of a mini channeled cold plate for using thermal management of a Li-Ion battery
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus77
rdl.citation.wos78
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)