Thermal–hydraulic performance of the circular-slice-shaped-winglet for tube bank heat exchanger
Özet
In this study, heat transfer performance of circular-slice-shaped-winglet (CSSW) for tube bank heat exchanger (TBHE) was numerically investigated. Circular-slice angle (α = 5°, 10° and 20°), layer gap (h/d = 0.08, 0.14, and 0.20) and winglet diameter (D/d = 1.60, 1.76 and 1.92) were analyzed as geometric parameters to obtain optimal design. Comprehensive numerical simulations were conducted under both laminar and turbulent flow (1100 ≤ Re ≤ 8500) conditions. Navier Stokes Equations were solved by using RNG k-ε turbulence model (with enhanced wall treatment). Colburn-j factor (j), friction factor (f), modified London area goodness factor (j/f1/3) and performance evaluation criterion (PEC) were investigated quantitatively. Flow characteristics were also analyzed to elucidate the underlying physics of the effects of CSSW on thermal-hydraulic performance for TBHE. Results were compared with the data related to bare tube heat exchanger, and showed that the highest modified London area goodness factor is 26.34% with α = 10°, h/d = 0.20 and D/d = 1.92 CSSW winglet design. Additionally, numerical calculations revealed that PEC increased to 1.356 with these CSSW design parameters, which corresponds to reduction of the required total heat transfer area by 36.60% compared to the bare tube heat exchanger for the same heat duty at a fixed pumping power. © 2022 Elsevier Masson SAS
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Tepe, Ahmet Ümit | |
| dc.contributor.author | Yilmaz, Harun | |
| dc.date.accessioned | 2026-10-18T20:27:45.431328448Z | |
| dc.date.available | 2026-10-18T20:27:45.431328448Z | |
| dc.date.issued | 2022 | |
| dc.description.abstract | In this study, heat transfer performance of circular-slice-shaped-winglet (CSSW) for tube bank heat exchanger (TBHE) was numerically investigated. Circular-slice angle (α = 5°, 10° and 20°), layer gap (h/d = 0.08, 0.14, and 0.20) and winglet diameter (D/d = 1.60, 1.76 and 1.92) were analyzed as geometric parameters to obtain optimal design. Comprehensive numerical simulations were conducted under both laminar and turbulent flow (1100 ≤ Re ≤ 8500) conditions. Navier Stokes Equations were solved by using RNG k-ε turbulence model (with enhanced wall treatment). Colburn-j factor (j), friction factor (f), modified London area goodness factor (j/f1/3) and performance evaluation criterion (PEC) were investigated quantitatively. Flow characteristics were also analyzed to elucidate the underlying physics of the effects of CSSW on thermal-hydraulic performance for TBHE. Results were compared with the data related to bare tube heat exchanger, and showed that the highest modified London area goodness factor is 26.34% with α = 10°, h/d = 0.20 and D/d = 1.92 CSSW winglet design. Additionally, numerical calculations revealed that PEC increased to 1.356 with these CSSW design parameters, which corresponds to reduction of the required total heat transfer area by 36.60% compared to the bare tube heat exchanger for the same heat duty at a fixed pumping power. © 2022 Elsevier Masson SAS | |
| dc.description.sponsorship | The authors gratefully acknowledge Erciyes University for the use of ANSYS /Fluent CFD code. | |
| dc.identifier.doi | 10.1016/j.ijthermalsci.2022.107711 | |
| dc.identifier.eissn | 1778-4166 | |
| dc.identifier.issn | 1290-0729 | |
| dc.identifier.scopus | 2-s2.0-85131053294 | |
| dc.identifier.startpage | 107711 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/12897 | |
| dc.identifier.volume | 179 | |
| dc.identifier.wos | WOS:000808369300001 | |
| dc.language.iso | en | |
| dc.publisher | Elsevier Masson s.r.l. | |
| dc.relation.ispartof | International Journal of Thermal Sciences | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | CFD | |
| dc.subject | Forced convection | |
| dc.subject | Tube bank heat exchanger | |
| dc.subject | Winglet | |
| dc.subject | Heat exchangers | |
| dc.subject | Navier Stokes equations | |
| dc.subject | Tubes (components) | |
| dc.subject | Turbulence models | |
| dc.subject | Bare tube heat exchanger | |
| dc.subject | Condition | |
| dc.subject | Heat transfer performance | |
| dc.subject | Laminar and turbulent flow | |
| dc.subject | Optimal design | |
| dc.subject | Performance evaluation criteria | |
| dc.subject | Thermal-hydraulic performance | |
| dc.subject | Tube banks | |
| dc.subject | Computational fluid dynamics | |
| dc.title | Thermal–hydraulic performance of the circular-slice-shaped-winglet for tube bank heat exchanger | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 10 | |
| rdl.citation.wos | 10 | |
| rdl.oa.status | green | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |