Single phase flow heat transfer characteristics of quad-channel twisted tape inserts in tubes

ArticleAçık Erişim

Özet

Heat transfer and pressure drop of turbulent fluid flow were studied numerically and experimentally in a quad-channel with twisted tapes placed in a circular tube under uniform heat flux boundary condition. All the tests were conducted with water as the working fluid where the turbulent flow range of Reynolds numbers were maintained at 4250 to 11000. Quad-channel twisted tapes (QCTT) were manufactured by 3D printer with the material PLA, the lengths of 50 mm, 100 mm, 200 mm with the twist ratio of 4.48. The tapes were identified with their tape/pipe length ratios (TPR) of 0.025, 0.05 and 0.1. Validation of the experimental data was performed by the comparison of the experimental results with the data from the well-known empirical correlations. Alteration of the friction factors and Nusselt numbers with the Reynolds numbers are presented in this paper. The results showed that the Nusselt number and the friction factor increased with the increasing of the length of QCTTs. On the other hand, the performance evaluation criteria (PEC) should be declining with the increase of the lengths of the tapes. The evaluated temperature distributions inside the tested tubes with the inserts were plotted in order to investigate the observed data. Based on the obtained experimental data, the empirical correlations for the Nusselt number within the deviation of ±2% and the friction factor within the deviation of ±5% were developed for the practical usage. © 2020 Elsevier Ltd

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13018Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorDalkılıç, Ahmet Selim
dc.contributor.authorUluç, Baran
dc.contributor.authorCellek, Mehmet Salih
dc.contributor.authorCelen, Ali
dc.contributor.authorJumpholkul, Chaiwat
dc.contributor.authorNewaz, Kazi Salim
dc.contributor.authorWongwises, Somchai
dc.date.accessioned2026-10-18T20:27:51.931468469Z
dc.date.available2026-10-18T20:27:51.931468469Z
dc.date.issued2020
dc.description.abstractHeat transfer and pressure drop of turbulent fluid flow were studied numerically and experimentally in a quad-channel with twisted tapes placed in a circular tube under uniform heat flux boundary condition. All the tests were conducted with water as the working fluid where the turbulent flow range of Reynolds numbers were maintained at 4250 to 11000. Quad-channel twisted tapes (QCTT) were manufactured by 3D printer with the material PLA, the lengths of 50 mm, 100 mm, 200 mm with the twist ratio of 4.48. The tapes were identified with their tape/pipe length ratios (TPR) of 0.025, 0.05 and 0.1. Validation of the experimental data was performed by the comparison of the experimental results with the data from the well-known empirical correlations. Alteration of the friction factors and Nusselt numbers with the Reynolds numbers are presented in this paper. The results showed that the Nusselt number and the friction factor increased with the increasing of the length of QCTTs. On the other hand, the performance evaluation criteria (PEC) should be declining with the increase of the lengths of the tapes. The evaluated temperature distributions inside the tested tubes with the inserts were plotted in order to investigate the observed data. Based on the obtained experimental data, the empirical correlations for the Nusselt number within the deviation of ±2% and the friction factor within the deviation of ±5% were developed for the practical usage. © 2020 Elsevier Ltd
dc.description.sponsorshipAll the authors are grateful to the management of Thailand Research Fund (TRF) , the National Research University Project (NRU) and King Mongkut's University of Technology Thonburi through the “ KMUTT 55th Anniversary Commemorative Fund ”.
dc.identifier.doi10.1016/j.icheatmasstransfer.2020.104835
dc.identifier.issn0735-1933
dc.identifier.scopus2-s2.0-85090145969
dc.identifier.startpage104835
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13018
dc.identifier.volume118
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofInternational Communications in Heat and Mass Transfer
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectConstant heat flux
dc.subjectDouble-pipe heat exchanger
dc.subjectPassive heat transfer enhancement
dc.subjectQuad-channel twisted tape
dc.subjectSingle phase flow
dc.subject3D printers
dc.subjectFriction
dc.subjectHeat flux
dc.subjectNusselt number
dc.subjectReynolds number
dc.subjectEmpirical correlations
dc.subjectHeat transfer and pressure drop
dc.subjectHeat transfer characteristics
dc.subjectPerformance evaluation criteria
dc.subjectSingle-phase flow
dc.subjectTurbulent fluid flow
dc.subjectTwisted tape insert
dc.subjectUniform heat flux boundaries
dc.subjectFlow of fluids
dc.titleSingle phase flow heat transfer characteristics of quad-channel twisted tape inserts in tubes
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus25
rdl.source.indexSCOPUS