Calibration of the CMS hadron calorimeters using proton-proton collision data at s = 13 TeV

Review ArticleAçık Erişim

Özet

Methods are presented for calibrating the hadron calorimeter system of the CMS detector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass and scintillator, and are in the form of one central detector and two endcaps. These calorimeters cover pseudorapidities |η| < 3 and are positioned inside the solenoidal magnet. An outer calorimeter, outside the magnet coil, covers |η| < 1.26, and a steel and quartz-fiber Cherenkov forward calorimeter extends the coverage to |η| < 5.19. The initial calibration of the calorimeters was based on results from test beams, augmented with the use of radioactive sources and lasers. The calibration was improved substantially using proton-proton collision data collected at s = 7, 8, and 13 TeV, as well as cosmic ray muon data collected during the periods when the LHC beams were not present. The present calibration is performed using the 13 TeV data collected during 2016 corresponding to an integrated luminosity of 35.9 fb-1. The intercalibration of channels exploits the approximate uniformity of energy collection over the azimuthal angle. The absolute energy scale of the central and endcap calorimeters is set using isolated charged hadrons. The energy scale for the electromagnetic portion of the forward calorimeters is set using Z→ ee data. The energy scale of the outer calorimeters has been determined with test beam data and is confirmed through data with high transverse momentum jets. In this paper, we present the details of the calibration methods and accuracy. © 2020 CERN for the benefit of the CMS collaboration..

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13770Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorSirunyan, A.M.
dc.contributor.authorTumasyan, A.
dc.contributor.authorAdam, W.
dc.contributor.authorAmbrogi, F.
dc.contributor.authorBergauer, T.
dc.contributor.authorBrandstetter, J.
dc.contributor.authorDragicevic, M.
dc.contributor.authorErö, J.
dc.contributor.authorEscalante Del Valle, A.
dc.contributor.authorFlechl, M.
dc.contributor.authorFrühwirth, R.
dc.contributor.authorJeitler, M.
dc.contributor.authorKrammer, N.
dc.contributor.authorKrätschmer, I.
dc.contributor.authorLiko, D.
dc.contributor.authorMadlener, T.
dc.contributor.authorMikulec, I.
dc.contributor.authorRad, N.
dc.contributor.authorSchieck, J.
dc.contributor.authorSchöfbeck, R.
dc.contributor.authorSpanring, M.
dc.contributor.authorSpitzbart, D.
dc.contributor.authorWaltenberger, W.
dc.contributor.authorWulz, C.-E.
dc.contributor.authorZarucki, M.
dc.contributor.authorChekhovsky, V.
dc.contributor.authorLitomin, A.
dc.contributor.authorMossolov, V.
dc.contributor.authorDarwish, M.R.
dc.contributor.authorDe Wolf, E.A.
dc.contributor.authorDi Croce, D.
dc.contributor.authorJanssen, X.
dc.contributor.authorLelek, A.
dc.contributor.authorPieters, M.
dc.contributor.authorRejeb Sfar, H.
dc.contributor.authorVan Haevermaet, H.
dc.contributor.authorVan Mechelen, P.
dc.contributor.authorVan Putte, S.
dc.contributor.authorVan Remortel, N.
dc.contributor.authorBlekman, F.
dc.contributor.authorBols, E.S.
dc.contributor.authorChhibra, S.S.
dc.contributor.authorD'Hondt, J.
dc.contributor.authorDe Clercq, J.
dc.contributor.authorLontkovskyi, D.
dc.contributor.authorLowette, S.
dc.contributor.authorMarchesini, I.
dc.contributor.authorMoortgat, S.
dc.contributor.authorMoreels, L.
dc.contributor.authorPython, Q.
dc.date.accessioned2026-10-18T20:28:35.389868798Z
dc.date.available2026-10-18T20:28:35.389868798Z
dc.date.issued2020
dc.description.abstractMethods are presented for calibrating the hadron calorimeter system of the CMS detector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass and scintillator, and are in the form of one central detector and two endcaps. These calorimeters cover pseudorapidities |η| < 3 and are positioned inside the solenoidal magnet. An outer calorimeter, outside the magnet coil, covers |η| < 1.26, and a steel and quartz-fiber Cherenkov forward calorimeter extends the coverage to |η| < 5.19. The initial calibration of the calorimeters was based on results from test beams, augmented with the use of radioactive sources and lasers. The calibration was improved substantially using proton-proton collision data collected at s = 7, 8, and 13 TeV, as well as cosmic ray muon data collected during the periods when the LHC beams were not present. The present calibration is performed using the 13 TeV data collected during 2016 corresponding to an integrated luminosity of 35.9 fb-1. The intercalibration of channels exploits the approximate uniformity of energy collection over the azimuthal angle. The absolute energy scale of the central and endcap calorimeters is set using isolated charged hadrons. The energy scale for the electromagnetic portion of the forward calorimeters is set using Z→ ee data. The energy scale of the outer calorimeters has been determined with test beam data and is confirmed through data with high transverse momentum jets. In this paper, we present the details of the calibration methods and accuracy. © 2020 CERN for the benefit of the CMS collaboration..
dc.description.sponsorshipHorizon 2020 Framework Programme, H2020, (675440, 752730, 765710); Horizon 2020 Framework Programme, H2020
dc.identifier.doi10.1088/1748-0221/15/05/p05002
dc.identifier.issn1748-0221
dc.identifier.issue5
dc.identifier.scopus2-s2.0-85086015865
dc.identifier.startpageP05002
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13770
dc.identifier.volume15
dc.language.isoen
dc.publisherInstitute of Physics
dc.relation.ispartofJournal of Instrumentation
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCalorimeters
dc.subjectPerformance of High Energy Physics Detectors
dc.subjectCalibration
dc.subjectCosmic rays
dc.subjectCosmology
dc.subjectHadrons
dc.subjectMagnets
dc.subjectParticle accelerators
dc.subjectRadioactivity
dc.subjectSteel fibers
dc.subjectTellurium compounds
dc.subjectCMS detectors
dc.subjectEndcaps
dc.subjectEnergy scale
dc.subjectHadron calorimeters
dc.subjectHigh energy physics detector
dc.subjectPerformance
dc.subjectPerformance of high energy physic detector
dc.subjectProton proton collisions
dc.subjectSampling calorimeters
dc.subjectTest beam
dc.titleCalibration of the CMS hadron calorimeters using proton-proton collision data at s = 13 TeV
dc.typeReview Article
dspace.entity.typePublication
rdl.citation.scopus7
rdl.oa.statusgold
rdl.source.indexSCOPUS