SSPWM three phase inverter design and experimented on unbalanced loads; [Konstrukcija SSPWM trofaznog izmjenjivača i primjena kod nestabilnih potrošača]

ArticleAçık Erişim

Özet

A circuit-oriented approach for the analysis of pulse width modulation (PWM) three phase inverter is presented in order to run unbalanced loads in low nonlinear effects as harmonics. This method uses the identification of a six switch nonlinear device, which consists of only the active and passive switches in three phase inverter. When operating characteristics of the MOSFET switch are determined according to step-sinus pulse width modulation method, an average equivalent inverter model can be formed. After that, SSPWM technique is used to drive unbalanced loads in order to compare with common pulse width modulation (PWM) running unstable loads. First, the inverter load of resistive (R) and inductive (L) are performed at the MATLAB Simulink so that by PWM technique could be shown the reducing effect of the harmonic on loads. After that, the system is implemented by real elements as MOSFETs, PIC17F877A, PC 817 phototransitors. © 2016, Strojarski Facultet. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/14757Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.17559/tv-20150730222021Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorCan, Erol
dc.contributor.authorSayan, H. Hüseyin
dc.date.accessioned2026-10-18T20:29:33.777591910Z
dc.date.available2026-10-18T20:29:33.777591910Z
dc.date.issued2016
dc.description.abstractA circuit-oriented approach for the analysis of pulse width modulation (PWM) three phase inverter is presented in order to run unbalanced loads in low nonlinear effects as harmonics. This method uses the identification of a six switch nonlinear device, which consists of only the active and passive switches in three phase inverter. When operating characteristics of the MOSFET switch are determined according to step-sinus pulse width modulation method, an average equivalent inverter model can be formed. After that, SSPWM technique is used to drive unbalanced loads in order to compare with common pulse width modulation (PWM) running unstable loads. First, the inverter load of resistive (R) and inductive (L) are performed at the MATLAB Simulink so that by PWM technique could be shown the reducing effect of the harmonic on loads. After that, the system is implemented by real elements as MOSFETs, PIC17F877A, PC 817 phototransitors. © 2016, Strojarski Facultet. All rights reserved.
dc.identifier.doi10.17559/tv-20150730222021
dc.identifier.eissn1848-6339
dc.identifier.endpage1244
dc.identifier.issn1330-3651
dc.identifier.issue5
dc.identifier.scopus2-s2.0-84991607105
dc.identifier.startpage1239
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/14757
dc.identifier.volume23
dc.identifier.wosWOS:000385369100001
dc.language.isoen
dc.publisherStrojarski Facultet
dc.relation.ispartofTehnicki Vjesnik
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectHarmonic
dc.subjectStep sinus pulse-width modulation
dc.subjectThe inverter
dc.subjectUnbalanced loads
dc.subjectHarmonic analysis
dc.subjectModulation
dc.subjectMOSFET devices
dc.subjectPulse width modulation
dc.subjectVoltage control
dc.subjectMATLAB/ SIMULINK
dc.subjectNon-linear devices
dc.subjectOperating characteristics
dc.subjectPassive switches
dc.subjectThree-phase inverter
dc.subjectElectric inverters
dc.titleSSPWM three phase inverter design and experimented on unbalanced loads; [Konstrukcija SSPWM trofaznog izmjenjivača i primjena kod nestabilnih potrošača]
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus10
rdl.citation.wos13
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)