Pharmacomechanical thrombectomy for acute symptomatic lower extremity deep venous thrombosis

ArticleAçık Erişim

Özet

Background: The purpose of this study was to evaluate the efficacy and safety of pharmacomechanical thrombectomy performed by using a rotational thrombectomy device for the treatment of deep vein thrombosis. Methods: Between April 2012 and November 2014, 17 patients with acute deep vein thrombosis underwent pharmacomechanical thrombolysis. The thrombectomy device was used in a single-session technique for patients with lower-extremity deep vein thrombosis. After the procedure, the effect of thrombolysis was evaluated in 3 grades venographically. Grade I showed lysis of under 50%, and grade III showed complete lysis. Results: Ten patients (58.8%) had an iliofemoral thrombosis and 7 (41.2%) had a femoropopliteal venous thrombosis. At the end of the pharmacomechanical thrombectomy procedure, 12 patients (70%) had complete (grade III) thrombus resolution. Grade I and II lysis were noted in 2 (12%) and 3 (18%) patients, respectively. Additionally, four (23.5%) required an additional lytic infusion as a result of residual thrombi. The overall grade III, II, and I thrombus resolution rates, including the supplemental thrombolysis, were 82.2% (n = 14), 12% (n = 2), and 5.8% (n = 1), respectively. There was no mortality. Conclusion: Based on the present data, use of the Cleaner thrombectomy device may prove to be a safe and feasible single-session pharmacomechanical thrombectomy method for the treatment of acute deep vein thrombosis. To prove the effectiveness of this type treatment, a more extensive largescale studies are needed. © 2015 Forum Multimedia Publishing, LLC.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/15052Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1532/hsf.1366Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorEyup, Serhat Calik
dc.contributor.authorOzgur, Dag
dc.contributor.authorMehmet, Ali Kaygin
dc.contributor.authorOruc, Alper Onk
dc.contributor.authorBilgehan, Erkutz
dc.date.accessioned2026-10-18T20:29:50.760046416Z
dc.date.available2026-10-18T20:29:50.760046416Z
dc.date.issued2015
dc.description.abstractBackground: The purpose of this study was to evaluate the efficacy and safety of pharmacomechanical thrombectomy performed by using a rotational thrombectomy device for the treatment of deep vein thrombosis. Methods: Between April 2012 and November 2014, 17 patients with acute deep vein thrombosis underwent pharmacomechanical thrombolysis. The thrombectomy device was used in a single-session technique for patients with lower-extremity deep vein thrombosis. After the procedure, the effect of thrombolysis was evaluated in 3 grades venographically. Grade I showed lysis of under 50%, and grade III showed complete lysis. Results: Ten patients (58.8%) had an iliofemoral thrombosis and 7 (41.2%) had a femoropopliteal venous thrombosis. At the end of the pharmacomechanical thrombectomy procedure, 12 patients (70%) had complete (grade III) thrombus resolution. Grade I and II lysis were noted in 2 (12%) and 3 (18%) patients, respectively. Additionally, four (23.5%) required an additional lytic infusion as a result of residual thrombi. The overall grade III, II, and I thrombus resolution rates, including the supplemental thrombolysis, were 82.2% (n = 14), 12% (n = 2), and 5.8% (n = 1), respectively. There was no mortality. Conclusion: Based on the present data, use of the Cleaner thrombectomy device may prove to be a safe and feasible single-session pharmacomechanical thrombectomy method for the treatment of acute deep vein thrombosis. To prove the effectiveness of this type treatment, a more extensive largescale studies are needed. © 2015 Forum Multimedia Publishing, LLC.
dc.identifier.doi10.1532/hsf.1366
dc.identifier.eissn1522-6662
dc.identifier.endpage183
dc.identifier.issn1098-3511
dc.identifier.issue4
dc.identifier.pmid26334857
dc.identifier.scopus2-s2.0-84941072877
dc.identifier.startpage178
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/15052
dc.identifier.volume18
dc.identifier.wosWOS:000370850300012
dc.language.isoen
dc.publisherCarden Jennings Publishing Co. Ltd
dc.relation.ispartofHeart Surgery Forum
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAdult
dc.subjectCombined Modality Therapy
dc.subjectFemale
dc.subjectHumans
dc.subjectLower Extremity
dc.subjectMale
dc.subjectMechanical Thrombolysis
dc.subjectMiddle Aged
dc.subjectThrombectomy
dc.subjectThrombolytic Therapy
dc.subjectTreatment Outcome
dc.subjectVenous Thrombosis
dc.subjectalteplase
dc.subjectheparin
dc.subjectlow molecular weight heparin
dc.subjectwarfarin
dc.subjectanticoagulant therapy
dc.subjectArticle
dc.subjectbleeding
dc.subjectblood clot lysis
dc.subjectblood vessel injury
dc.subjectclinical article
dc.subjectechography
dc.subjectfemoropopliteal vein thrombosis
dc.subjectgingiva bleeding
dc.subjecthematoma
dc.subjecthuman
dc.subjectiliofemoral thrombosis
dc.subjectleg phlebography
dc.subjectlower extremity deep vein thrombosis
dc.titlePharmacomechanical thrombectomy for acute symptomatic lower extremity deep venous thrombosis
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus4
rdl.citation.wos3
rdl.departmentDepartment of Cardiovascular Surgery, Erzincan University Medical Faculty, Erzincan, Turkey.
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)