Pharmacomechanical thrombectomy for acute symptomatic lower extremity deep venous thrombosis
Özet
Background: The purpose of this study was to evaluate the efficacy and safety of pharmacomechanical thrombectomy performed by using a rotational thrombectomy device for the treatment of deep vein thrombosis. Methods: Between April 2012 and November 2014, 17 patients with acute deep vein thrombosis underwent pharmacomechanical thrombolysis. The thrombectomy device was used in a single-session technique for patients with lower-extremity deep vein thrombosis. After the procedure, the effect of thrombolysis was evaluated in 3 grades venographically. Grade I showed lysis of under 50%, and grade III showed complete lysis. Results: Ten patients (58.8%) had an iliofemoral thrombosis and 7 (41.2%) had a femoropopliteal venous thrombosis. At the end of the pharmacomechanical thrombectomy procedure, 12 patients (70%) had complete (grade III) thrombus resolution. Grade I and II lysis were noted in 2 (12%) and 3 (18%) patients, respectively. Additionally, four (23.5%) required an additional lytic infusion as a result of residual thrombi. The overall grade III, II, and I thrombus resolution rates, including the supplemental thrombolysis, were 82.2% (n = 14), 12% (n = 2), and 5.8% (n = 1), respectively. There was no mortality. Conclusion: Based on the present data, use of the Cleaner thrombectomy device may prove to be a safe and feasible single-session pharmacomechanical thrombectomy method for the treatment of acute deep vein thrombosis. To prove the effectiveness of this type treatment, a more extensive largescale studies are needed. © 2015 Forum Multimedia Publishing, LLC.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Eyup, Serhat Calik | |
| dc.contributor.author | Ozgur, Dag | |
| dc.contributor.author | Mehmet, Ali Kaygin | |
| dc.contributor.author | Oruc, Alper Onk | |
| dc.contributor.author | Bilgehan, Erkutz | |
| dc.date.accessioned | 2026-10-18T20:29:50.760046416Z | |
| dc.date.available | 2026-10-18T20:29:50.760046416Z | |
| dc.date.issued | 2015 | |
| dc.description.abstract | Background: The purpose of this study was to evaluate the efficacy and safety of pharmacomechanical thrombectomy performed by using a rotational thrombectomy device for the treatment of deep vein thrombosis. Methods: Between April 2012 and November 2014, 17 patients with acute deep vein thrombosis underwent pharmacomechanical thrombolysis. The thrombectomy device was used in a single-session technique for patients with lower-extremity deep vein thrombosis. After the procedure, the effect of thrombolysis was evaluated in 3 grades venographically. Grade I showed lysis of under 50%, and grade III showed complete lysis. Results: Ten patients (58.8%) had an iliofemoral thrombosis and 7 (41.2%) had a femoropopliteal venous thrombosis. At the end of the pharmacomechanical thrombectomy procedure, 12 patients (70%) had complete (grade III) thrombus resolution. Grade I and II lysis were noted in 2 (12%) and 3 (18%) patients, respectively. Additionally, four (23.5%) required an additional lytic infusion as a result of residual thrombi. The overall grade III, II, and I thrombus resolution rates, including the supplemental thrombolysis, were 82.2% (n = 14), 12% (n = 2), and 5.8% (n = 1), respectively. There was no mortality. Conclusion: Based on the present data, use of the Cleaner thrombectomy device may prove to be a safe and feasible single-session pharmacomechanical thrombectomy method for the treatment of acute deep vein thrombosis. To prove the effectiveness of this type treatment, a more extensive largescale studies are needed. © 2015 Forum Multimedia Publishing, LLC. | |
| dc.identifier.doi | 10.1532/hsf.1366 | |
| dc.identifier.eissn | 1522-6662 | |
| dc.identifier.endpage | 183 | |
| dc.identifier.issn | 1098-3511 | |
| dc.identifier.issue | 4 | |
| dc.identifier.pmid | 26334857 | |
| dc.identifier.scopus | 2-s2.0-84941072877 | |
| dc.identifier.startpage | 178 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/15052 | |
| dc.identifier.volume | 18 | |
| dc.identifier.wos | WOS:000370850300012 | |
| dc.language.iso | en | |
| dc.publisher | Carden Jennings Publishing Co. Ltd | |
| dc.relation.ispartof | Heart Surgery Forum | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Adult | |
| dc.subject | Combined Modality Therapy | |
| dc.subject | Female | |
| dc.subject | Humans | |
| dc.subject | Lower Extremity | |
| dc.subject | Male | |
| dc.subject | Mechanical Thrombolysis | |
| dc.subject | Middle Aged | |
| dc.subject | Thrombectomy | |
| dc.subject | Thrombolytic Therapy | |
| dc.subject | Treatment Outcome | |
| dc.subject | Venous Thrombosis | |
| dc.subject | alteplase | |
| dc.subject | heparin | |
| dc.subject | low molecular weight heparin | |
| dc.subject | warfarin | |
| dc.subject | anticoagulant therapy | |
| dc.subject | Article | |
| dc.subject | bleeding | |
| dc.subject | blood clot lysis | |
| dc.subject | blood vessel injury | |
| dc.subject | clinical article | |
| dc.subject | echography | |
| dc.subject | femoropopliteal vein thrombosis | |
| dc.subject | gingiva bleeding | |
| dc.subject | hematoma | |
| dc.subject | human | |
| dc.subject | iliofemoral thrombosis | |
| dc.subject | leg phlebography | |
| dc.subject | lower extremity deep vein thrombosis | |
| dc.title | Pharmacomechanical thrombectomy for acute symptomatic lower extremity deep venous thrombosis | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 4 | |
| rdl.citation.wos | 3 | |
| rdl.department | Department of Cardiovascular Surgery, Erzincan University Medical Faculty, Erzincan, Turkey. | |
| rdl.oa.status | gold | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.source.index | PUBMED | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |
