Surgical removal of intra-abdominal intrauterine devices at one center in a 20-year period

ArticleAçık Erişim

Özet

Objective To review 20 years of experience of the removal of intra-abdominal intrauterine devices (IUDs) and to compare the surgical methods used.; Methods In a retrospective study, charts dating from between September 1, 1992, and August 31, 2012, were reviewed. Patients were eligible for inclusion when they had an IUD surgically removed by minilaparotomy or laparoscopy at a tertiary referral center in Izmir, Turkey.; Results Among the 36 eligible women, 18 (50%) had undergone laparoscopy and 18 (50%) had undergone minilaparotomy. Mean operation length was 55.3 ± 6.3 minutes in the laparoscopy group and 29.1 ± 4.2 minutes in the minilaparotomy group (P = 0.008). Conversion to full laparotomy was necessary in 4 (22%) women in the laparoscopy group and 1 (6%) in the minilaparotomy group (P = 0.02). Perioperative complications were observed in 5 (14%) women, with no difference in frequency between groups (P = 0.09). Total cost of medical/surgical procedures was US$436.4 ± 35.4 for the laparoscopy group and $323.4 ± 21.3 for the minilaparotomy group (P = 0.04).; Conclusion Minilaparotomy seems to be an important alternative to laparoscopy for the removal of intra-abdominal IUDs. This procedure should be an integral part of gynecologic surgical training. © 2014 International Federation of Gynecology and Obstetrics.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/15095Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1016/j.ijgo.2014.07.025Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorErtopcu, Kenan
dc.contributor.authorNayki, Cenk
dc.contributor.authorUlug, Pasa
dc.contributor.authorNayki, Umit
dc.contributor.authorGultekin, Emre
dc.contributor.authorDonmez, Aysegul
dc.contributor.authorYildirim, Yusuf
dc.date.accessioned2026-10-18T20:29:53.130295117Z
dc.date.available2026-10-18T20:29:53.130295117Z
dc.date.issued2015
dc.description.abstractObjective To review 20 years of experience of the removal of intra-abdominal intrauterine devices (IUDs) and to compare the surgical methods used.; Methods In a retrospective study, charts dating from between September 1, 1992, and August 31, 2012, were reviewed. Patients were eligible for inclusion when they had an IUD surgically removed by minilaparotomy or laparoscopy at a tertiary referral center in Izmir, Turkey.; Results Among the 36 eligible women, 18 (50%) had undergone laparoscopy and 18 (50%) had undergone minilaparotomy. Mean operation length was 55.3 ± 6.3 minutes in the laparoscopy group and 29.1 ± 4.2 minutes in the minilaparotomy group (P = 0.008). Conversion to full laparotomy was necessary in 4 (22%) women in the laparoscopy group and 1 (6%) in the minilaparotomy group (P = 0.02). Perioperative complications were observed in 5 (14%) women, with no difference in frequency between groups (P = 0.09). Total cost of medical/surgical procedures was US$436.4 ± 35.4 for the laparoscopy group and $323.4 ± 21.3 for the minilaparotomy group (P = 0.04).; Conclusion Minilaparotomy seems to be an important alternative to laparoscopy for the removal of intra-abdominal IUDs. This procedure should be an integral part of gynecologic surgical training. © 2014 International Federation of Gynecology and Obstetrics.
dc.identifier.doi10.1016/j.ijgo.2014.07.025
dc.identifier.eissn1879-3479
dc.identifier.endpage13
dc.identifier.issn0020-7292
dc.identifier.issue1
dc.identifier.pmid25249316
dc.identifier.scopus2-s2.0-84917672995
dc.identifier.startpage10
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/15095
dc.identifier.volume128
dc.identifier.wosWOS:000348266600006
dc.language.isoen
dc.publisherElsevier Ireland Ltd
dc.relation.ispartofInternational Journal of Gynecology and Obstetrics
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectIntra-abdominal intrauterine devices
dc.subjectLaparoscopy
dc.subjectMinilaparotomy
dc.subjectAdolescent
dc.subjectAdult
dc.subjectConversion to Open Surgery
dc.subjectDevice Removal
dc.subjectDouglas' Pouch
dc.subjectFemale
dc.subjectHumans
dc.subjectIntrauterine Device Migration
dc.subjectIntrauterine Devices
dc.subjectLaparotomy
dc.subjectOperative Time
dc.subjectRetrospective Studies
dc.subjectTurkey
dc.subjectYoung Adult
dc.subjectlidocaine
dc.subjectpropofol
dc.subjectabdominal tenderness
dc.subjectabscess
dc.subjectappendectomy
dc.subjectArticle
dc.subjectasymptomatic disease
dc.subjectcesarean section
dc.subjectclinical article
dc.subjectcost effectiveness analysis
dc.subjectdyspareunia
dc.subjectdysuria
dc.subjecthospitalization cost
dc.titleSurgical removal of intra-abdominal intrauterine devices at one center in a 20-year period
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus5
rdl.citation.wos5
rdl.departmentDepartment of Obstetrics and Gynecology, Erzincan University School of Medicine, Erzincan, Turkey. | Department of Gynecology and Family Planning, Aegean Obstetrics and Gynecology Education and Research Hospital, Izmir, Turkey
rdl.departmentDepartment of Obstetrics and Gynecology, Erzincan University School of Medicine, Erzincan, Turkey. Electronic address: dr.yusufyildirim2@yahoo.com.tr.
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)