Flow injection potentiometric determination of silver(I) in photographic film developing solution samples by polyvinylchloride membrane silver(I) selective electrode

ArticleAçık Erişim

Özet

A polyvinylchloride (PVC) membrane silver(I) selective electrode was developed for the determination of silver(I) ions in photographic film developing solutions. The electrode was embedded into a home-made flow cell and successfully used as a potentiometric detector in a flow injection potentiometric (FIP) system. Under the optimized flow injection conditions, the electrode exhibited a non-Nernstian slope of 67.20±0.80 mV in the linear range from 1.0×10-5 to 1.0×10-1 mol/L (R2=0.9961) and the lowest value for limit of detection (LOD) was calculated as 7.1×10-6 mol/L. The electrode displayed good sensitivity, selectivity, repeatable and rapid response towards silver(I) ions. Lifetime of the electrode was determined as at least two months in FIP system. The electrode was also successfully applied for the potentiometric determination of silver(I) ions in photographic film developing solution samples in FIP system. The results attained from FIP system were compared with the atomic absorption spectrophotometry (AAS) results by using student's t-test at 95 % confidence level and relative deviation (RD) between the two methods was < 8 %. © 2016, Chemical Society of Pakistan. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/15171Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorTopcu, Cihan
dc.contributor.authorColdur, Fatih
dc.contributor.authorAndac, Muberra
dc.contributor.authorCubuk, Osman
dc.contributor.authorKanberoglu, Gulsah Saydan
dc.contributor.authorCaglar, Bulent
dc.contributor.authorIsildak, Ibrahim
dc.date.accessioned2026-10-18T20:29:57.638062011Z
dc.date.available2026-10-18T20:29:57.638062011Z
dc.date.issued2016
dc.description.abstractA polyvinylchloride (PVC) membrane silver(I) selective electrode was developed for the determination of silver(I) ions in photographic film developing solutions. The electrode was embedded into a home-made flow cell and successfully used as a potentiometric detector in a flow injection potentiometric (FIP) system. Under the optimized flow injection conditions, the electrode exhibited a non-Nernstian slope of 67.20±0.80 mV in the linear range from 1.0×10-5 to 1.0×10-1 mol/L (R2=0.9961) and the lowest value for limit of detection (LOD) was calculated as 7.1×10-6 mol/L. The electrode displayed good sensitivity, selectivity, repeatable and rapid response towards silver(I) ions. Lifetime of the electrode was determined as at least two months in FIP system. The electrode was also successfully applied for the potentiometric determination of silver(I) ions in photographic film developing solution samples in FIP system. The results attained from FIP system were compared with the atomic absorption spectrophotometry (AAS) results by using student's t-test at 95 % confidence level and relative deviation (RD) between the two methods was < 8 %. © 2016, Chemical Society of Pakistan. All rights reserved.
dc.identifier.endpage888
dc.identifier.issn0253-5106
dc.identifier.issue5
dc.identifier.scopus2-s2.0-84995487634
dc.identifier.startpage881
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/15171
dc.identifier.volume38
dc.language.isoen
dc.publisherChemical Society of Pakistan
dc.relation.ispartofJournal of the Chemical Society of Pakistan
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectFlow injection potentiometry
dc.subjectPhotographic film developing solution
dc.subjectPotentiometric analysis
dc.subjectSilver(I) selective electrode
dc.titleFlow injection potentiometric determination of silver(I) in photographic film developing solution samples by polyvinylchloride membrane silver(I) selective electrode
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus1
rdl.source.indexSCOPUS