Neurotoxicity of various root canal sealers on rat sciatic nerve: an electrophysiologic and histopathologic study

ArticleAçık Erişim

Özet

Objectives: The aim of this study was to compare the neurotoxicity of various root canal sealers on rat sciatic nerve by electrophysiologic and histopathologic analyses. Materials and methods: A total of 40 male rats were randomly divided into five groups: Control, AH Plus, GuttaFlow, Sealapex and Smartpastebio. Sciatic nerves of the rats were uncovered using the surgical procedures, and the prepared sealers were then applied on nerves with a polyethylene tube vehicle for 15 days. Nerve potentials were recorded at initial exposure, 5, 30 and 120 min (early phase), and 15 days (late phase) by an electrophysiologic analysis system for all groups. The obtained measurements were then used to calculate the nerve conduction velocities (NCV). Subsequently, all rats were sacrificed, and their sciatic nerves were removed for histopathologic analysis. Statistical analysis was performed using the Kruskal-Wallis and Mann-Whitney U tests for intergroup variables and the Friedman and Wilcoxon test for intragroup variables. Statistical significance was set at P < 0.05. Results: There was no significant difference between early and late phase results in the control group. This group showed little or no lasting damage to nerve tissue. All sealers decreased the NCV in the early phase time periods, but this decrease was only statistically significant in the AH Plus group at 120-min time period (P < 0.0125). During the late phase, the AH Plus and GuttaFlow groups almost reached initial NCV values, and it was lower than the initial values in the Sealapex and Smartpastebio groups. However, this decrease was not statistically significant. When intergroup comparisons were performed, statistically significant differences occurred at 30 min in the Sealapex group and 120 min in the AH Plus group compared with the control group (P < 0.0125). All sealers induced neurotoxicity as a result of degenerative and inflammatory responses of nerve tissue in histologic analysis. Histologic analysis revealed Sealapex and GuttaFlow to be the most and least neurotoxic, respectively. Conclusions: All tested root canal sealers exhibited a variable degree of neurotoxicity depending on their chemical compositions. Clinical relevance: Apical extrusion of endodontic filling materials may cause undesired consequences, such as inflammation and severe neurotoxic damage; therefore, extrusion factor plays an important role during the root canal treatment. © 2015, Springer-Verlag Berlin Heidelberg.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/15248Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s00784-015-1447-yYayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorTuğ Kılkış, Buket
dc.contributor.authorEr, Kürşat
dc.contributor.authorTaşdemir, Tamer
dc.contributor.authorYildirim, Mehmet
dc.contributor.authorTaskesen, Fatih
dc.contributor.authorTümkaya, Levent
dc.contributor.authorKalkan, Yıldıray
dc.contributor.authorSerper, Ahmet
dc.date.accessioned2026-10-18T20:30:03.069502009Z
dc.date.available2026-10-18T20:30:03.069502009Z
dc.date.issued2015
dc.description.abstractObjectives: The aim of this study was to compare the neurotoxicity of various root canal sealers on rat sciatic nerve by electrophysiologic and histopathologic analyses. Materials and methods: A total of 40 male rats were randomly divided into five groups: Control, AH Plus, GuttaFlow, Sealapex and Smartpastebio. Sciatic nerves of the rats were uncovered using the surgical procedures, and the prepared sealers were then applied on nerves with a polyethylene tube vehicle for 15 days. Nerve potentials were recorded at initial exposure, 5, 30 and 120 min (early phase), and 15 days (late phase) by an electrophysiologic analysis system for all groups. The obtained measurements were then used to calculate the nerve conduction velocities (NCV). Subsequently, all rats were sacrificed, and their sciatic nerves were removed for histopathologic analysis. Statistical analysis was performed using the Kruskal-Wallis and Mann-Whitney U tests for intergroup variables and the Friedman and Wilcoxon test for intragroup variables. Statistical significance was set at P < 0.05. Results: There was no significant difference between early and late phase results in the control group. This group showed little or no lasting damage to nerve tissue. All sealers decreased the NCV in the early phase time periods, but this decrease was only statistically significant in the AH Plus group at 120-min time period (P < 0.0125). During the late phase, the AH Plus and GuttaFlow groups almost reached initial NCV values, and it was lower than the initial values in the Sealapex and Smartpastebio groups. However, this decrease was not statistically significant. When intergroup comparisons were performed, statistically significant differences occurred at 30 min in the Sealapex group and 120 min in the AH Plus group compared with the control group (P < 0.0125). All sealers induced neurotoxicity as a result of degenerative and inflammatory responses of nerve tissue in histologic analysis. Histologic analysis revealed Sealapex and GuttaFlow to be the most and least neurotoxic, respectively. Conclusions: All tested root canal sealers exhibited a variable degree of neurotoxicity depending on their chemical compositions. Clinical relevance: Apical extrusion of endodontic filling materials may cause undesired consequences, such as inflammation and severe neurotoxic damage; therefore, extrusion factor plays an important role during the root canal treatment. © 2015, Springer-Verlag Berlin Heidelberg.
dc.identifier.doi10.1007/s00784-015-1447-y
dc.identifier.endpage2100
dc.identifier.issn1432-6981
dc.identifier.issue8
dc.identifier.pmid25773448
dc.identifier.scopus2-s2.0-84942984057
dc.identifier.startpage2091
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/15248
dc.identifier.volume19
dc.language.isoen
dc.publisherSpringer Verlag
dc.relation.ispartofClinical Oral Investigations
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAH Plus
dc.subjectAnimal study
dc.subjectGuttaFlow
dc.subjectNeurotoxicity
dc.subjectRat sciatic nerve
dc.subjectRoot canal sealer
dc.subjectSealapex
dc.subjectSmartpastebio
dc.subjectAnimals
dc.subjectDental Pulp Cavity
dc.subjectElectrophysiological Phenomena
dc.subjectMale
dc.subjectNeurotoxicity Syndromes
dc.subjectRats
dc.subjectRats, Sprague-Dawley
dc.subjectRoot Canal Filling Materials
dc.subjectSciatic Nerve
dc.subjectroot canal filling material
dc.subjectanimal
dc.subjectdrug effects
dc.subjectelectrophysiology
dc.subjectinnervation
dc.subjectpathology
dc.subjectpathophysiology
dc.subjectrat
dc.subjectSprague Dawley rat
dc.subjecttoxicity and intoxication
dc.titleNeurotoxicity of various root canal sealers on rat sciatic nerve: an electrophysiologic and histopathologic study
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus10
rdl.departmentDepartment of Oral and Maxillofacial Surgery, Faculty of Dentistry, Erzincan University, Erzincan, Turkey.
rdl.source.indexSCOPUS
rdl.source.indexPUBMED