PVC-membrane potentiometric sensor for the determination of tamoxifen in pharmaceutical formulations
Özet
Novel tamoxifen-selective potentiometric electrodes based on various ion associations of tamoxifen were developed. The most suitable membrane composition, which has the best potentiometric characteristics, was examined under steady-state conditions. The membrane composed of (w/w) 3% tamoxifen-phosphomolibdate ion pair, 32% poly(vinylchloride), and 65% 2-nitrophenyloctylether was determined as the membrane with the best analytical properties. On the condition of pH=2-6, the fabricated electrode exhibited linear responses over the concentration range of 9.1 × 10-6- 1 × 10-3 M tamoxifen solutions (R2 =0.9989) with a sensitivity of 42.9 ± 0.3 mV/decade, detection limit of 7.3 ± 0.4 × 10-6 M and short response time of ≈25 s. The influences of some alkaline, alkaline earth metals, biologically significant molecules, and some pharmaceutical species over electrode responses were studied. The proposed electrode was applied for the determination of tamoxifen contents of some pharmaceutical formulations by using standard addition method. The potentiometric analysis results obtained for the pharmaceutical formulations were in good harmony with the results obtained by high performance liquid chromatography at 95% confidence level. © 2001-2012 IEEE.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Kanberoglu, Gulsah Saydan | |
| dc.contributor.author | Coldur, Fatih | |
| dc.contributor.author | Topcu, Cihan | |
| dc.contributor.author | Cubuk, Osman | |
| dc.date.accessioned | 2026-10-18T20:30:13.621865842Z | |
| dc.date.available | 2026-10-18T20:30:13.621865842Z | |
| dc.date.issued | 2015 | |
| dc.description.abstract | Novel tamoxifen-selective potentiometric electrodes based on various ion associations of tamoxifen were developed. The most suitable membrane composition, which has the best potentiometric characteristics, was examined under steady-state conditions. The membrane composed of (w/w) 3% tamoxifen-phosphomolibdate ion pair, 32% poly(vinylchloride), and 65% 2-nitrophenyloctylether was determined as the membrane with the best analytical properties. On the condition of pH=2-6, the fabricated electrode exhibited linear responses over the concentration range of 9.1 × 10-6- 1 × 10-3 M tamoxifen solutions (R2 =0.9989) with a sensitivity of 42.9 ± 0.3 mV/decade, detection limit of 7.3 ± 0.4 × 10-6 M and short response time of ≈25 s. The influences of some alkaline, alkaline earth metals, biologically significant molecules, and some pharmaceutical species over electrode responses were studied. The proposed electrode was applied for the determination of tamoxifen contents of some pharmaceutical formulations by using standard addition method. The potentiometric analysis results obtained for the pharmaceutical formulations were in good harmony with the results obtained by high performance liquid chromatography at 95% confidence level. © 2001-2012 IEEE. | |
| dc.description.sponsorship | This work was supported by Yuzuncu Yil University Research Foundation under Grant 2013-FEN-B044. The associate editor coordinating the review of this paper and approving it for publication was Dr. Pantelis Georgiou. | |
| dc.identifier.doi | 10.1109/jsen.2015.2454053 | |
| dc.identifier.eissn | 1558-1748 | |
| dc.identifier.endpage | 6207 | |
| dc.identifier.issn | 1530-437X | |
| dc.identifier.issue | 11 | |
| dc.identifier.scopus | 2-s2.0-84941595446 | |
| dc.identifier.startpage | 6199 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/15401 | |
| dc.identifier.volume | 15 | |
| dc.identifier.wos | WOS:000360450900018 | |
| dc.language.iso | en | |
| dc.publisher | Institute of Electrical and Electronics Engineers Inc. | |
| dc.relation.ispartof | IEEE Sensors Journal | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Drug analysis | |
| dc.subject | Ion-selective electrode | |
| dc.subject | Tamoxifen determination | |
| dc.subject | Alkalinity | |
| dc.subject | Chemical analysis | |
| dc.subject | Chemical sensors | |
| dc.subject | Drug products | |
| dc.subject | Electrodes | |
| dc.subject | High performance liquid chromatography | |
| dc.subject | Ions | |
| dc.subject | Liquid chromatography | |
| dc.subject | Potentiometers (electric measuring instruments) | |
| dc.subject | Analytical properties | |
| dc.subject | Pharmaceutical formulation | |
| dc.subject | Potentiometric analysis | |
| dc.subject | Potentiometric electrode | |
| dc.subject | Standard addition method | |
| dc.subject | Steady-state condition | |
| dc.subject | Tamoxifen | |
| dc.subject | Ion selective electrodes | |
| dc.title | PVC-membrane potentiometric sensor for the determination of tamoxifen in pharmaceutical formulations | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 32 | |
| rdl.citation.wos | 28 | |
| rdl.oa.status | green | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |