Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at √s = 7 TeV

ArticleAçık Erişim

Özet

The energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of √s = 7 TeV with integrated luminosities of about 5fb-1. Crucial aspects of detector operation, such as the environmental stability, alignment, and synchronization, are presented. The in-situ calibration procedures are discussed in detail and include the maintenance of the calibration in the challenging radiation environment inside the CMS detector. The energy resolution for electrons from Z-boson decays is better than 2% in the central region of the ECAL barrel (for pseudorapidity |η| < 0.8) and is 2-5% elsewhere. The derived energy resolution for photons from 125 GeV Higgs boson decays varies across the barrel from 1.1% to 2.6% and from 2.2% to 5% in the endcaps. The calibration of the absolute energy is determined from Ze→+e - decays to a precision of 0.4% in the barrel and 0.8% in the endcaps. © 2013 CERN for the benefit of the CMS collaboration.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/15535Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorChatrchyan, S.
dc.contributor.authorKhachatryan, V.
dc.contributor.authorSirunyan, A.M.
dc.contributor.authorTumasyan, A.
dc.contributor.authorAdam, W.
dc.contributor.authorBergauer, T.
dc.contributor.authorDragicevic, M.
dc.contributor.authorErö, J.
dc.contributor.authorFabjan, C.
dc.contributor.authorFriedl, M.
dc.contributor.authorFrühwirth, R.
dc.contributor.authorGhete, V.M.
dc.contributor.authorHörmann, N.
dc.contributor.authorHrubec, J.
dc.contributor.authorJeitler, M.
dc.contributor.authorKiesenhofer, W.
dc.contributor.authorKnünz, V.
dc.contributor.authorKrammer, M.
dc.contributor.authorKrätschmer, I.
dc.contributor.authorLiko, D.
dc.contributor.authorMikulec, I.
dc.contributor.authorRabady, D.
dc.contributor.authorRahbaran, B.
dc.contributor.authorRohringer, C.
dc.contributor.authorRohringer, H.
dc.contributor.authorSchöfbeck, R.
dc.contributor.authorStrauss, J.
dc.contributor.authorTaurok, A.
dc.contributor.authorTreberer-Treberspurg, W.
dc.contributor.authorWaltenberger, W.
dc.contributor.authorWulz, C.-E.
dc.contributor.authorMossolov, V.
dc.contributor.authorShumeiko, N.
dc.contributor.authorSuarez Gonzalez, J.
dc.contributor.authorAlderweireldt, S.
dc.contributor.authorBansal, M.
dc.contributor.authorBansal, S.
dc.contributor.authorCornelis, T.
dc.contributor.authorDe Wolf, E.A.
dc.contributor.authorJanssen, X.
dc.contributor.authorKnutsson, A.
dc.contributor.authorLuyckx, S.
dc.contributor.authorMucibello, L.
dc.contributor.authorOchesanu, S.
dc.contributor.authorRoland, B.
dc.contributor.authorRougny, R.
dc.contributor.authorVan Haevermaet, H.
dc.contributor.authorVan Mechelen, P.
dc.contributor.authorVan Remortel, N.
dc.contributor.authorVan Spilbeeck, A.
dc.date.accessioned2026-10-18T20:30:23.297146116Z
dc.date.available2026-10-18T20:30:23.297146116Z
dc.date.issued2013
dc.description.abstractThe energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of √s = 7 TeV with integrated luminosities of about 5fb-1. Crucial aspects of detector operation, such as the environmental stability, alignment, and synchronization, are presented. The in-situ calibration procedures are discussed in detail and include the maintenance of the calibration in the challenging radiation environment inside the CMS detector. The energy resolution for electrons from Z-boson decays is better than 2% in the central region of the ECAL barrel (for pseudorapidity |η| < 0.8) and is 2-5% elsewhere. The derived energy resolution for photons from 125 GeV Higgs boson decays varies across the barrel from 1.1% to 2.6% and from 2.2% to 5% in the endcaps. The calibration of the absolute energy is determined from Ze→+e - decays to a precision of 0.4% in the barrel and 0.8% in the endcaps. © 2013 CERN for the benefit of the CMS collaboration.
dc.description.sponsorshipNational Science Foundation, NSF, (0906479, 0969555, 1151640, 1205960, 1211067, 1306951, 1314131); National Science Foundation, NSF; Schweizerischer Nationalfonds zur F&#x00F6;rderung der Wissenschaftlichen Forschung, SNF, (138111, 144921, 146398, 146730); Schweizerischer Nationalfonds zur F&#x00F6;rderung der Wissenschaftlichen Forschung, SNF
dc.identifier.doi10.1088/1748-0221/8/09/p09009
dc.identifier.issn1748-0221
dc.identifier.issue9
dc.identifier.scopus2-s2.0-84885944582
dc.identifier.startpageP09009
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/15535
dc.identifier.volume8
dc.language.isoen
dc.publisherInstitute of Physics
dc.relation.ispartofJournal of Instrumentation
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCalorimeters
dc.subjectGamma detectors (scintillators, CZT, HPG, HgI etc)
dc.subjectLarge detector systems for particle and astroparticle physics
dc.subjectBosons
dc.subjectCalibration
dc.subjectGermanium compounds
dc.subjectIodine compounds
dc.subjectMercury compounds
dc.subjectReadout systems
dc.subjectTellurium compounds
dc.subjectAstroparticle physics
dc.subjectCentre-of-mass energies
dc.subjectElectromagnetic calorimeter
dc.subjectEnvironmental stability
dc.subjectGamma detectors
dc.subjectIntegrated luminosity
dc.subjectProton proton collisions
dc.subjectRadiation environments
dc.subjectPhosphorus compounds
dc.titleEnergy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at √s = 7 TeV
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus145
rdl.oa.statusgold
rdl.source.indexSCOPUS