Comparison of different legation techniques in laparoscopic varicocelectomy

ArticleAçık Erişim

Özet

Aim: To evaluate the effects of different intracorporeal legation techniques with titanium clips, Plasma Trisector (Gyrus, USA) (PTG), and surgical silk on bilateral laparoscopic varicocelectomy (LPVx). Materials and methods: Between May 2009 and August 2012, 100 patients who underwent bilateral LPVx were evaluated. Te demographic parameters of patients, preoperative radiological findings, semen analysis, operative data, and follow-up were recorded. All of the patients were divided into 3 groups, randomized prospectively. Te patients whose veins were legated by 5-mm titanium clips were included in group I, those whose veins were legated by PTG were included in group II, and those whose veins were legated by surgical silk were included in group III. Te recorded data of the groups were analyzed. Results: Mean follow-up time was 18.8 ± 1.1 months. According to the demographics of age, body mass index, spermiogram, and diameter of veins before surgery, there were no statistical differences between any of the groups (P > 0.05). However, operation time was longer in group III (P < 0.0001), while total numbers of legated veins did not differ among the groups (P > 0.05). Additionally, hospital stay, oral intake, and complications were not different among the groups (P > 0.05). In follow-up the sperm count analysis was higher than the preoperative count analysis for all of the groups (P < 0.05). Conclusion: PTG may provide a shorter operation time than using titanium clips and/or surgical silk in LPVx. Additionally, PTG may increase sperm count with fewer complications than the other legation techniques in LPVx. Terefore, PTG may be the new candidate electrosurgical standard device for LPVx in the nearby future. © TÜBİTAK.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/15607Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.3906/sag-1211-11Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAkin, Yiǧit
dc.contributor.authorAteş, Mutlu
dc.contributor.authorYücel, Selçuk
dc.contributor.authorBaşara, Işil
dc.contributor.authorÇelik, Orçun
dc.contributor.authorBozkurt, Aliseydi
dc.contributor.authorNuhoǧlu, Bariş
dc.date.accessioned2026-10-18T20:30:27.445501999Z
dc.date.available2026-10-18T20:30:27.445501999Z
dc.date.issued2014
dc.description.abstractAim: To evaluate the effects of different intracorporeal legation techniques with titanium clips, Plasma Trisector (Gyrus, USA) (PTG), and surgical silk on bilateral laparoscopic varicocelectomy (LPVx). Materials and methods: Between May 2009 and August 2012, 100 patients who underwent bilateral LPVx were evaluated. Te demographic parameters of patients, preoperative radiological findings, semen analysis, operative data, and follow-up were recorded. All of the patients were divided into 3 groups, randomized prospectively. Te patients whose veins were legated by 5-mm titanium clips were included in group I, those whose veins were legated by PTG were included in group II, and those whose veins were legated by surgical silk were included in group III. Te recorded data of the groups were analyzed. Results: Mean follow-up time was 18.8 ± 1.1 months. According to the demographics of age, body mass index, spermiogram, and diameter of veins before surgery, there were no statistical differences between any of the groups (P > 0.05). However, operation time was longer in group III (P < 0.0001), while total numbers of legated veins did not differ among the groups (P > 0.05). Additionally, hospital stay, oral intake, and complications were not different among the groups (P > 0.05). In follow-up the sperm count analysis was higher than the preoperative count analysis for all of the groups (P < 0.05). Conclusion: PTG may provide a shorter operation time than using titanium clips and/or surgical silk in LPVx. Additionally, PTG may increase sperm count with fewer complications than the other legation techniques in LPVx. Terefore, PTG may be the new candidate electrosurgical standard device for LPVx in the nearby future. © TÜBİTAK.
dc.identifier.doi10.3906/sag-1211-11
dc.identifier.eissn1303-6165
dc.identifier.endpage278
dc.identifier.issn1300-0144
dc.identifier.issue2
dc.identifier.pmid25536736
dc.identifier.scopus2-s2.0-84892401995
dc.identifier.startpage273
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/15607
dc.identifier.volume44
dc.identifier.wosWOS:000329790100017
dc.language.isoen
dc.publisherTurkiye Klinikleri Journal of Medical Sciences
dc.relation.ispartofTurkish Journal of Medical Sciences
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectComplications
dc.subjectElectrosurgery
dc.subjectLaparoscopy
dc.subjectLigation techniques
dc.subjectVaricocele
dc.subjectVaricocelectomy
dc.subjectAdult
dc.subjectHemostasis, Surgical
dc.subjectHumans
dc.subjectLigation
dc.subjectMale
dc.subjectOperative Time
dc.subjectPostoperative Complications
dc.subjectProspective Studies
dc.subjectSutures
dc.subjectTitanium
dc.subjectarticle
dc.subjectbleeding
dc.subjectbody mass
dc.subjectcauterization
dc.subjectclip
dc.subjectemphysema
dc.subjectfollow up
dc.subjecthernia
dc.subjecthuman
dc.subjecthydrocele
dc.subjectmajor clinical study
dc.subjectoperation duration
dc.subjectpain
dc.subjectrandomized controlled trial
dc.titleComparison of different legation techniques in laparoscopic varicocelectomy
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus5
rdl.citation.wos5
rdl.oa.statusopen
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)