Stable signal separation algorithm for ECG signals
Conference ObjectAçık Erişim
Özet
Electrocardiogram (ECG) signal has biomedical signs showing the working activity of the heart muscle by human body. Being able to take these biomedical signs from human body is important for diagnosis. Although there are a lot of Independent Component Analysis (ICA) algorithms that separate ECG signals from noises in the literature, separation qualities of them depend on initial conditions. The aim of this study is to find an ICA algorithm giving the stable separation quality for different initial conditions. Experimental results show that Kernel Independent Component Analysis algorithm (KICA) provides more accurate and stable results than the other algorithms. © 2012 IEEE.
Anahtar Kelimeler
BSSECGFICAICAJADEKICANMFAlgorithmsBlind source separationElectrocardiographyIntelligent systemsSeparationSilicate mineralsECG signalsElectrocardiogram signalHeart musclesHuman bodiesICA algorithmsInitial conditionsKernel independent component analysisSignal separation algorithmsIndependent component analysis
RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/15654Resmi atıflarda kullanılan kalıcı adresTam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Ilgin, Fatih Yavuz | |
| dc.contributor.author | Celik, Hüsamettin | |
| dc.contributor.author | Sevim, Yusuf | |
| dc.date.accessioned | 2026-10-18T20:30:30.257903081Z | |
| dc.date.available | 2026-10-18T20:30:30.257903081Z | |
| dc.date.issued | 2012 | |
| dc.description.abstract | Electrocardiogram (ECG) signal has biomedical signs showing the working activity of the heart muscle by human body. Being able to take these biomedical signs from human body is important for diagnosis. Although there are a lot of Independent Component Analysis (ICA) algorithms that separate ECG signals from noises in the literature, separation qualities of them depend on initial conditions. The aim of this study is to find an ICA algorithm giving the stable separation quality for different initial conditions. Experimental results show that Kernel Independent Component Analysis algorithm (KICA) provides more accurate and stable results than the other algorithms. © 2012 IEEE. | |
| dc.identifier.doi | 10.1109/inista.2012.6246990 | |
| dc.identifier.isbn | 978-146731446-6 | |
| dc.identifier.scopus | 2-s2.0-84866594874 | |
| dc.identifier.startpage | 6246990 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/15654 | |
| dc.language.iso | en | |
| dc.relation.ispartof | INISTA 2012 - International Symposium on INnovations in Intelligent SysTems and Applications | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | BSS | |
| dc.subject | ECG | |
| dc.subject | FICA | |
| dc.subject | ICA | |
| dc.subject | JADE | |
| dc.subject | KICA | |
| dc.subject | NMF | |
| dc.subject | Algorithms | |
| dc.subject | Blind source separation | |
| dc.subject | Electrocardiography | |
| dc.subject | Intelligent systems | |
| dc.subject | Separation | |
| dc.subject | Silicate minerals | |
| dc.subject | ECG signals | |
| dc.subject | Electrocardiogram signal | |
| dc.subject | Heart muscles | |
| dc.subject | Human bodies | |
| dc.subject | ICA algorithms | |
| dc.subject | Initial conditions | |
| dc.subject | Kernel independent component analysis | |
| dc.subject | Signal separation algorithms | |
| dc.subject | Independent component analysis | |
| dc.title | Stable signal separation algorithm for ECG signals | |
| dc.type | Conference Object | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 1 | |
| rdl.source.index | SCOPUS |