Comparison of vessel sealing systems with conventional
Özet
Background: Haemorrhoids are cushions of submucosal vascular tissue located in the anal canal starting just distal to the dentate line. Haemorrhoidal disease is a common anorectal disorder which has symptoms of bleeding, prolapse, pain, thrombosis, mucus discharge, and pruritus. Haemorrhoidectomy is one of most frequently performed anorectal operation worldwide. Objectives: The aim of this study was to compare the effectiveness of the LigaSure tissue sealing device, Harmonic Scalpel and conventional MM open haemorrhoidectomy. Materials and Methods: Sixty-nine patients with newly diagnosed symptomatic grade three or grade four haemorrhoidal disease, from July 2011 to December 2011 were recruited for the study. Patients were prospectively randomized to LigaSure, Harmonic Scalpel and conventional haemorrhoidectomy. Patients were evaluated on the basis of the mean operative time, postoperative pain, day of discharge, early and late complications. Results: Each group has twenty-three patients. Ten (14.5 %) were female and fifty-nine (85.5 %) were male. Mean age were 44.5 ± 10.8 for LigaSure group, 39.5±14.4 for Harmonic Scalpel group and 39.8 ± 13.6 for conventional haemorrhoidectomy group. Mean operative time was 12.6 ± 2.9 for LigaSure group, 12.6 ± 2.5 for Harmonic Scalpel group and 22.3 ± 4.5 for conventional haemorrhoidectomy group. Postoperative pain and required analgesic dose were significantly lower for conventional haemorrhoidectomy. Wound healing was also more rapid in conventional haemorrhoidectomy than both LigaSure and Harmonic Scalpel. Conclusions: Lateral heat dissipation of energy based cautery such as Harmonel Scalpel and LigaSure is considerably high when compared with conventional methods. More thermal damage which is generated on tissue seems to be the reason for increased degree of postoperative pain and delay in wound healing. © 2013, Iranian Red Crescent Medical Journal.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Peker, Kemal | |
| dc.contributor.author | Inal, Abdullah | |
| dc.contributor.author | Güllü, Huriye | |
| dc.contributor.author | Gül, Düriye | |
| dc.contributor.author | Şahin, Murat | |
| dc.contributor.author | Ozcan, Ayca Dumanli | |
| dc.contributor.author | Kiliç, Kemal | |
| dc.date.accessioned | 2026-10-18T20:30:49.489963540Z | |
| dc.date.available | 2026-10-18T20:30:49.489963540Z | |
| dc.date.issued | 2013 | |
| dc.description.abstract | Background: Haemorrhoids are cushions of submucosal vascular tissue located in the anal canal starting just distal to the dentate line. Haemorrhoidal disease is a common anorectal disorder which has symptoms of bleeding, prolapse, pain, thrombosis, mucus discharge, and pruritus. Haemorrhoidectomy is one of most frequently performed anorectal operation worldwide. Objectives: The aim of this study was to compare the effectiveness of the LigaSure tissue sealing device, Harmonic Scalpel and conventional MM open haemorrhoidectomy. Materials and Methods: Sixty-nine patients with newly diagnosed symptomatic grade three or grade four haemorrhoidal disease, from July 2011 to December 2011 were recruited for the study. Patients were prospectively randomized to LigaSure, Harmonic Scalpel and conventional haemorrhoidectomy. Patients were evaluated on the basis of the mean operative time, postoperative pain, day of discharge, early and late complications. Results: Each group has twenty-three patients. Ten (14.5 %) were female and fifty-nine (85.5 %) were male. Mean age were 44.5 ± 10.8 for LigaSure group, 39.5±14.4 for Harmonic Scalpel group and 39.8 ± 13.6 for conventional haemorrhoidectomy group. Mean operative time was 12.6 ± 2.9 for LigaSure group, 12.6 ± 2.5 for Harmonic Scalpel group and 22.3 ± 4.5 for conventional haemorrhoidectomy group. Postoperative pain and required analgesic dose were significantly lower for conventional haemorrhoidectomy. Wound healing was also more rapid in conventional haemorrhoidectomy than both LigaSure and Harmonic Scalpel. Conclusions: Lateral heat dissipation of energy based cautery such as Harmonel Scalpel and LigaSure is considerably high when compared with conventional methods. More thermal damage which is generated on tissue seems to be the reason for increased degree of postoperative pain and delay in wound healing. © 2013, Iranian Red Crescent Medical Journal. | |
| dc.identifier.doi | 10.5812/ircmj.10180 | |
| dc.identifier.eissn | 2074-1812 | |
| dc.identifier.endpage | 496 | |
| dc.identifier.issn | 2074-1804 | |
| dc.identifier.issue | 6 | |
| dc.identifier.pmcid | PMC3840836 | |
| dc.identifier.pmid | 24349747 | |
| dc.identifier.scopus | 2-s2.0-84885760489 | |
| dc.identifier.startpage | 488 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/15980 | |
| dc.identifier.volume | 15 | |
| dc.identifier.wos | WOS:000329608300008 | |
| dc.language.iso | en | |
| dc.publisher | Iranian Red Crescent Society | |
| dc.relation.ispartof | Iranian Red Crescent Medical Journal | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Haemorrhoidectomy | |
| dc.subject | Harmonic Scalpel | |
| dc.subject | LigaSure | |
| dc.subject | diclofenac | |
| dc.subject | tramadol | |
| dc.subject | adult | |
| dc.subject | aged | |
| dc.subject | article | |
| dc.subject | bleeding | |
| dc.subject | controlled study | |
| dc.subject | female | |
| dc.subject | hemorrhoid | |
| dc.subject | hemorrhoidectomy | |
| dc.subject | human | |
| dc.subject | major clinical study | |
| dc.subject | male | |
| dc.subject | operation duration | |
| dc.subject | peroperative complication | |
| dc.subject | postoperative care | |
| dc.subject | postoperative pain | |
| dc.subject | prospective study | |
| dc.subject | randomized controlled trial | |
| dc.subject | rectoscopy | |
| dc.subject | scalpel | |
| dc.subject | surgical equipment | |
| dc.subject | tissue sealing device | |
| dc.subject | vessel sealing system | |
| dc.subject | visual analog scale | |
| dc.subject | wound healing | |
| dc.title | Comparison of vessel sealing systems with conventional | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 11 | |
| rdl.citation.wos | 6 | |
| rdl.department | Erzincan University Department of General Surgery, Erzincan, Turkey. | Erzincan University Department of Anesthesiology & Reanimation, Erzincan, Turkey. | |
| rdl.oa.status | green | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.source.index | PUBMED | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |
