Second law analysis of transient heat transfer for turbulent flow in a circular tube with baffle inserts

ArticleAçık Erişim

Özet

This paper presents the resülts of an experimental investigation of transient forced convective heat transfer for turbulent flow of nine circular tubes with baffle plate inserts using different pitch to tube inlet diameter ratios and baffle orientation angles in the range of Reynolds number 3000 < Re < 20000 in the case of constant heat flux. The characteristic parameters of the tubes are: pitch to tube inlet diameter ratio H/D — 1, 2 and 3; baffle orientation angle ß — 45, 90 and 180 degree. Air, having a Prandtl number of 0.71 was used as the working fluid, while stainless steel was considered as the pipe material. The data show that unsteady entropy generation numbers for the baffled tubes are higher than those from the steady one. A generalised correlation for the unsteady entropy generation number relative to the steady dimensional entropy generation number for the baffle inserted tubes has been developed. © 2005 Inderscience Enterprises Ltd.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/16032Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1504/ijex.2005.007257Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorTandiroglu, Ahmet
dc.date.accessioned2026-10-18T20:30:52.262215270Z
dc.date.available2026-10-18T20:30:52.262215270Z
dc.date.issued2005
dc.description.abstractThis paper presents the resülts of an experimental investigation of transient forced convective heat transfer for turbulent flow of nine circular tubes with baffle plate inserts using different pitch to tube inlet diameter ratios and baffle orientation angles in the range of Reynolds number 3000 < Re < 20000 in the case of constant heat flux. The characteristic parameters of the tubes are: pitch to tube inlet diameter ratio H/D — 1, 2 and 3; baffle orientation angle ß — 45, 90 and 180 degree. Air, having a Prandtl number of 0.71 was used as the working fluid, while stainless steel was considered as the pipe material. The data show that unsteady entropy generation numbers for the baffled tubes are higher than those from the steady one. A generalised correlation for the unsteady entropy generation number relative to the steady dimensional entropy generation number for the baffle inserted tubes has been developed. © 2005 Inderscience Enterprises Ltd.
dc.identifier.doi10.1504/ijex.2005.007257
dc.identifier.endpage317
dc.identifier.issn1742-8297
dc.identifier.issue3
dc.identifier.scopus2-s2.0-33645869223
dc.identifier.startpage299
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/16032
dc.identifier.volume2
dc.language.isoen
dc.relation.ispartofInternational Journal of Exergy
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectcircular tube with baffle inserts
dc.subjectheat transfer augmentation
dc.subjecttransient forced convection
dc.titleSecond law analysis of transient heat transfer for turbulent flow in a circular tube with baffle inserts
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus5
rdl.source.indexSCOPUS