Indoor and outdoor gamma dose measurements for specific counties of Trabzon-Turkey

Conference ObjectAçık Erişim

Özet

In this study, it was determined environmental gamma radiation dose rate for some counties of Trabzon-Turkey. A detailed ambient gamma dose measurement has been performed in the seven counties of Trabzon, using a portable environmental survey meter (NaI detector, INSPECTOR 1000). The measurements were performed indoor and outdoor of buildings and also at each spot, a reading was taken at 1 m above ground level. The dose rates varied from 42.69 nGy/h and 140.91 nGy/h for indoor gamma dose and 27.84 nGy/h and 121.80 nGy/h for outdoor gamma dose. Average indoor and outdoor gamma dose rates were ascertained to be 71.05 nGy/h and 60.20 nGy/h, respectively. The annual effective doses were calculated from indoor and outdoor gamma doses to be 348.56 μSv/y and 73.83 μSv/y, respectively. © 2009 American Institute of Physics.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/16170Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1063/1.3322471Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKurnaz, Asli
dc.contributor.authorKüçükömeroǧlu, B.
dc.contributor.authorOkumuşoǧlu, N.T.
dc.contributor.authorYeşilbaǧ, Y.Ö.
dc.date.accessioned2026-10-18T20:30:58.657238539Z
dc.date.available2026-10-18T20:30:58.657238539Z
dc.date.issued2010
dc.description.abstractIn this study, it was determined environmental gamma radiation dose rate for some counties of Trabzon-Turkey. A detailed ambient gamma dose measurement has been performed in the seven counties of Trabzon, using a portable environmental survey meter (NaI detector, INSPECTOR 1000). The measurements were performed indoor and outdoor of buildings and also at each spot, a reading was taken at 1 m above ground level. The dose rates varied from 42.69 nGy/h and 140.91 nGy/h for indoor gamma dose and 27.84 nGy/h and 121.80 nGy/h for outdoor gamma dose. Average indoor and outdoor gamma dose rates were ascertained to be 71.05 nGy/h and 60.20 nGy/h, respectively. The annual effective doses were calculated from indoor and outdoor gamma doses to be 348.56 μSv/y and 73.83 μSv/y, respectively. © 2009 American Institute of Physics.
dc.identifier.doi10.1063/1.3322471
dc.identifier.endpage381
dc.identifier.isbn978-073540740-4
dc.identifier.issn1551-7616
dc.identifier.scopus2-s2.0-76749162918
dc.identifier.startpage379
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/16170
dc.identifier.volume1203
dc.language.isoen
dc.relation.ispartofAIP Conference Proceedings
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectEffective doses
dc.subjectGamma doses
dc.subjectNaI detector
dc.subjectTrabzon
dc.titleIndoor and outdoor gamma dose measurements for specific counties of Trabzon-Turkey
dc.typeConference Object
dspace.entity.typePublication
rdl.citation.scopus2
rdl.source.indexSCOPUS