Measurement of the effective atomic numbers of compounds with cerium near to the absorption edge

ArticleAçık Erişim

Özet

In order to measure atomic, molecular and electronic cross-section; the effective atomic number, density of electron and absorption jump factor, we have first measured μt values of compounds which are determined by mixture rule using transmission method. In order to measure experimentally the effective atomic number within absorption jump factors of compounds with Ce, the X-ray source used Am-241 whose gamma rays were stopped at secondary source (Sm), thus producing Kα and Kβ X-ray emission. The most crucial finding in this study is that measurement of the effective atomic number is not appropriate near to the absorption edge and the effective atomic number is affected by near to the absorption edge. The results obtained have been compared with theoretical values. © 2010 Elsevier B.V. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/16193Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1016/j.nima.2010.01.039Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorPolat, Recep
dc.contributor.authorIçelli, Orhan
dc.date.accessioned2026-10-18T20:30:59.742239250Z
dc.date.available2026-10-18T20:30:59.742239250Z
dc.date.issued2010
dc.description.abstractIn order to measure atomic, molecular and electronic cross-section; the effective atomic number, density of electron and absorption jump factor, we have first measured μt values of compounds which are determined by mixture rule using transmission method. In order to measure experimentally the effective atomic number within absorption jump factors of compounds with Ce, the X-ray source used Am-241 whose gamma rays were stopped at secondary source (Sm), thus producing Kα and Kβ X-ray emission. The most crucial finding in this study is that measurement of the effective atomic number is not appropriate near to the absorption edge and the effective atomic number is affected by near to the absorption edge. The results obtained have been compared with theoretical values. © 2010 Elsevier B.V. All rights reserved.
dc.identifier.doi10.1016/j.nima.2010.01.039
dc.identifier.eissn1872-9576
dc.identifier.endpage210
dc.identifier.issn0168-9002
dc.identifier.issue2
dc.identifier.scopus2-s2.0-77649271806
dc.identifier.startpage201
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/16193
dc.identifier.volume615
dc.identifier.wosWOS:000276299900005
dc.language.isoen
dc.publisherELSEVIER
dc.relation.ispartofNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAtomic
dc.subjectJump factor
dc.subjectJump ratio
dc.subjectMolecular and electronic cross-sections
dc.subjectThe effective atomic number
dc.subjectAbsorption
dc.subjectCerium
dc.subjectCerium compounds
dc.subjectGamma rays
dc.subjectParticle detectors
dc.subjectAbsorption edges
dc.subjectAbsorption jumps
dc.subjectAtomic jump
dc.subjectDensity of electrons
dc.subjectEffective atomic number
dc.subjectTheoretical values
dc.subjectX-ray emission
dc.subjectX-ray sources
dc.subjectAtoms
dc.titleMeasurement of the effective atomic numbers of compounds with cerium near to the absorption edge
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus19
rdl.citation.wos19
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)