The inverter with reverse connected double converter driving unbalanced loads

ArticleAçık Erişim

Özet

Inverter circuits play an important role in providing energy to multiple loads or energy lines. In cases where power lines or loads are unbalanced, it is important to balance and regulate the power it carries. Therefore, in this study, an inverter structure with an inverted connecting double dc-dc converter is used to drive unbalanced loads. While load balancing is performed by changing the widths of the pulse width modulation that make up the voltage in load balancing methods in other inverter studies, the maximum point of the generated voltage is changed by affecting the operating times of the converters in this study. First, the circuit structure and the working order of the circuit are given. Then three-phase balanced and unbalanced loads are driven. The unbalanced loads driven are finally balanced with the proposed circuit structure. Distortions of load currents are decreased as %3, 51. This distortion value is lower than 4% reported by the international IEEE, while the obtained load currents maintain a smooth sinusoidal structure.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/16225Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorCan, Erol
dc.date.accessioned2026-10-18T20:33:43.137720301Z
dc.date.available2026-10-18T20:33:43.137720301Z
dc.date.issued2022
dc.description.abstractInverter circuits play an important role in providing energy to multiple loads or energy lines. In cases where power lines or loads are unbalanced, it is important to balance and regulate the power it carries. Therefore, in this study, an inverter structure with an inverted connecting double dc-dc converter is used to drive unbalanced loads. While load balancing is performed by changing the widths of the pulse width modulation that make up the voltage in load balancing methods in other inverter studies, the maximum point of the generated voltage is changed by affecting the operating times of the converters in this study. First, the circuit structure and the working order of the circuit are given. Then three-phase balanced and unbalanced loads are driven. The unbalanced loads driven are finally balanced with the proposed circuit structure. Distortions of load currents are decreased as %3, 51. This distortion value is lower than 4% reported by the international IEEE, while the obtained load currents maintain a smooth sinusoidal structure.
dc.identifier.doi10.1080/02286203.2021.1871720
dc.identifier.eissn1925-7082
dc.identifier.endpage226
dc.identifier.issn0228-6203
dc.identifier.issue2
dc.identifier.startpage217
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/16225
dc.identifier.volume42
dc.identifier.wosWOS:000616269000001
dc.language.isoen
dc.publisherTAYLOR & FRANCIS INC
dc.relation.ispartofINTERNATIONAL JOURNAL OF MODELLING AND SIMULATION
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectMaximum point
dc.subjectinverted connecting
dc.subjectload balancing
dc.subjectoptimize the power
dc.subjectEngineering, Multidisciplinary
dc.subjectMathematics, Interdisciplinary Applications
dc.subjectEngineering
dc.subjectMathematics
dc.titleThe inverter with reverse connected double converter driving unbalanced loads
dc.typeArticle
dspace.entity.typePublication
rdl.citation.wos14
rdl.source.indexWOS
rdl.wos.indexEmerging Sources Citation Index (ESCI)