Analysis of preanalytical errors by different autoanalyzer and sample types

ArticleAçık Erişim

Özet

Aim: In this study, it was aimed to determine the causes of preanalytical errors according to the different autoanalyzer and sample types. Material and Method: The rejected biological samples were analyzed in the laboratory information system of Mengucek Gazi Training and Research Hospital between January 1, 2017 and December 31, 2017. According to device types, reasons for rejection and rejection rates were identified. Results: At the indicated dates, 748758 samples were reached in the laboratory, of which 4245 (0.56 %) were rejected. The reasons for rejection are mostly following: incorrect test request (53.6 %) and hemolysis (22.6 %) in the biochemistry samples, inadequate sample (61.5 %) and incorrect test request (30.2 %) in hormone samples, clotted samples (76.9 %) and incorrect sample container (7.9 %) in hemogram samples, level error (38.5 %) and clotted sample (31.3%) In coagulation samples, clotted sample (89.1%) and inadequate sample (5.7 %) in the blood gas samples, incorrect sample container (53.7 %) and incorrect test request (21.1 %) in the nephelometer samples, incorrect sample container (37.4 %) and clotted samples (34.1 %) in the sedimentation samples were identified. Discussion: The preanalytical error sources vary according to the sample types and autoanalyzers. These results should be stated in personnel training and necessary precautions should be taken.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/16685Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.4328/acam.6029Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorMertoglu, Cuma
dc.date.accessioned2026-10-18T20:36:33.299944963Z
dc.date.available2026-10-18T20:36:33.299944963Z
dc.date.issued2019
dc.description.abstractAim: In this study, it was aimed to determine the causes of preanalytical errors according to the different autoanalyzer and sample types. Material and Method: The rejected biological samples were analyzed in the laboratory information system of Mengucek Gazi Training and Research Hospital between January 1, 2017 and December 31, 2017. According to device types, reasons for rejection and rejection rates were identified. Results: At the indicated dates, 748758 samples were reached in the laboratory, of which 4245 (0.56 %) were rejected. The reasons for rejection are mostly following: incorrect test request (53.6 %) and hemolysis (22.6 %) in the biochemistry samples, inadequate sample (61.5 %) and incorrect test request (30.2 %) in hormone samples, clotted samples (76.9 %) and incorrect sample container (7.9 %) in hemogram samples, level error (38.5 %) and clotted sample (31.3%) In coagulation samples, clotted sample (89.1%) and inadequate sample (5.7 %) in the blood gas samples, incorrect sample container (53.7 %) and incorrect test request (21.1 %) in the nephelometer samples, incorrect sample container (37.4 %) and clotted samples (34.1 %) in the sedimentation samples were identified. Discussion: The preanalytical error sources vary according to the sample types and autoanalyzers. These results should be stated in personnel training and necessary precautions should be taken.
dc.identifier.doi10.4328/acam.6029
dc.identifier.eissn2667-663X
dc.identifier.endpage562
dc.identifier.issue5
dc.identifier.startpage559
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/16685
dc.identifier.volume10
dc.identifier.wosWOS:000512905300009
dc.language.isoen
dc.publisherBAYRAKOL MEDICAL PUBLISHER
dc.relation.ispartofANNALS OF CLINICAL AND ANALYTICAL MEDICINE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectPreanalytical Error
dc.subjectHemolysis
dc.subjectClotted Samples
dc.subjectInsufficient Sample
dc.subjectIncorrect Test Request
dc.subjectIncorrect Sample Container
dc.subjectLABORATORY MEDICINE
dc.subjectQUALITY INDICATORS
dc.subjectREJECTION
dc.subjectMedicine, General & Internal
dc.subjectGeneral & Internal Medicine
dc.titleAnalysis of preanalytical errors by different autoanalyzer and sample types