Numerical investigation on the usage of finned surface in lithium nickel manganese cobalt oxides batteries by using air cooling method

ArticleAçık Erişim

Özet

In this study, a numerical thermal analysis of a lithium nickel manganese cobalt oxide prismatic battery having nominal voltage of 3.7 V and capacity of 26Ah was performed during air cooling conditions. The effects of discharge rate (in the range of 3C-5C) and air velocity (in the range of 1-3 m s(-1)) on average battery temperature, maximum battery temperature, and total heat transfer rate are investigated for both flat and finned cooling surfaces. The results showed that air cooling by means of flat cooling surface is only sufficient for low discharge rate and it is necessary to use finned surfaces in order to keep battery temperature in desired operation temperature range for high discharge rate conditions. Analysis results showed that average battery temperature is reduced up to 29%, 32%, and 30% by increasing air velocity for discharge rates of 3C, 4C, and 5C with the usage of flat surface, respectively. In addition, it was seen that the average and maximum battery temperatures are reduced up to 7.9 and 8.6 K with the usage of finned cooling surface instead of flat one. The heat removed from the battery is increased 8.7 W by using finned surface at the maximum air velocity of 3 ms(-1).

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/16696Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1002/est2.216Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorCelen, Ali
dc.contributor.authorKalkan, Orhan
dc.date.accessioned2026-10-18T20:36:33.797488619Z
dc.date.available2026-10-18T20:36:33.797488619Z
dc.date.issued2021
dc.description.abstractIn this study, a numerical thermal analysis of a lithium nickel manganese cobalt oxide prismatic battery having nominal voltage of 3.7 V and capacity of 26Ah was performed during air cooling conditions. The effects of discharge rate (in the range of 3C-5C) and air velocity (in the range of 1-3 m s(-1)) on average battery temperature, maximum battery temperature, and total heat transfer rate are investigated for both flat and finned cooling surfaces. The results showed that air cooling by means of flat cooling surface is only sufficient for low discharge rate and it is necessary to use finned surfaces in order to keep battery temperature in desired operation temperature range for high discharge rate conditions. Analysis results showed that average battery temperature is reduced up to 29%, 32%, and 30% by increasing air velocity for discharge rates of 3C, 4C, and 5C with the usage of flat surface, respectively. In addition, it was seen that the average and maximum battery temperatures are reduced up to 7.9 and 8.6 K with the usage of finned cooling surface instead of flat one. The heat removed from the battery is increased 8.7 W by using finned surface at the maximum air velocity of 3 ms(-1).
dc.identifier.doi10.1002/est2.216
dc.identifier.eissn2578-4862
dc.identifier.issue1
dc.identifier.startpagee216
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/16696
dc.identifier.volume3
dc.identifier.wosWOS:000647122700010
dc.language.isoen
dc.publisherWILEY
dc.relation.ispartofENERGY STORAGE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectbattery air cooling
dc.subjectelectric vehicle
dc.subjectfinned surface
dc.subjectheat removal
dc.subjectnumerical simulation
dc.subjectTHERMAL MANAGEMENT-SYSTEM
dc.subjectPHASE-CHANGE MATERIAL
dc.subjectLI-ION BATTERIES
dc.subjectHEAT-PIPE
dc.subjectPOWER BATTERY
dc.subjectFLOW CONFIGURATION
dc.subjectPOUCH BATTERY
dc.subjectPERFORMANCE
dc.subjectDESIGN
dc.subjectPACK
dc.subjectEnergy & Fuels
dc.titleNumerical investigation on the usage of finned surface in lithium nickel manganese cobalt oxides batteries by using air cooling method
dc.typeArticle
dspace.entity.typePublication
rdl.citation.wos16
rdl.source.indexWOS
rdl.wos.indexEmerging Sources Citation Index (ESCI)