Investigation of Fracture Resistance of Zirconia Restorations After Different Surface Treatments
Özet
Objective: The purpose of this study was to investigate the effects of the different surface treatments on fracture strength of the zirconia-based ceramic restorations. Methods: Each of 120 dental implant abutments and analogs were used in the present study. Zirconia core materials were manufactured on dental implants by using CAD/CAM device and they were randomly divided into 6 groups (n=20) according to surface pretreatments; control group (Group C), airborne-particle abrasion (Group AA), silica-coating (Group SC), Nd:YAG laser (Group N), bur-cut from cervical region (Group BC), and bur-cut on the functional tubercule (Group BT). Cementation was succeeded with two different types of cements including a dual-cure resin-cement and a glass ionomer cement. The obtained data were evaluated statistically using one-way ANOVA and Tukey tests (p=0.05). Results: No statistically significant difference was found between the groups (p>0.05). Similarly, no statistically significant difference was found between the resin cement and glass ionomer groups with respect to fracture strength values (p>0.05). Conclusion: Within the limitations of the present study, surface treatments and cement have no effect on the flexural strength of zirconia ceramic crowns.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Akar, Turker | |
| dc.contributor.author | Akin, Hakan | |
| dc.date.accessioned | 2026-10-18T20:38:52.147749372Z | |
| dc.date.available | 2026-10-18T20:38:52.147749372Z | |
| dc.date.issued | 2021 | |
| dc.description.abstract | Objective: The purpose of this study was to investigate the effects of the different surface treatments on fracture strength of the zirconia-based ceramic restorations. Methods: Each of 120 dental implant abutments and analogs were used in the present study. Zirconia core materials were manufactured on dental implants by using CAD/CAM device and they were randomly divided into 6 groups (n=20) according to surface pretreatments; control group (Group C), airborne-particle abrasion (Group AA), silica-coating (Group SC), Nd:YAG laser (Group N), bur-cut from cervical region (Group BC), and bur-cut on the functional tubercule (Group BT). Cementation was succeeded with two different types of cements including a dual-cure resin-cement and a glass ionomer cement. The obtained data were evaluated statistically using one-way ANOVA and Tukey tests (p=0.05). Results: No statistically significant difference was found between the groups (p>0.05). Similarly, no statistically significant difference was found between the resin cement and glass ionomer groups with respect to fracture strength values (p>0.05). Conclusion: Within the limitations of the present study, surface treatments and cement have no effect on the flexural strength of zirconia ceramic crowns. | |
| dc.identifier.doi | 10.33808/clinexphealthsci.796603 | |
| dc.identifier.eissn | 2459-1459 | |
| dc.identifier.endpage | 321 | |
| dc.identifier.issn | 2459-1459 | |
| dc.identifier.issue | 2 | |
| dc.identifier.startpage | 318 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/16763 | |
| dc.identifier.volume | 11 | |
| dc.identifier.wos | WOS:000681330400021 | |
| dc.language.iso | en | |
| dc.publisher | MARMARA UNIV, INST HEALTH SCIENCES | |
| dc.relation.ispartof | CLINICAL AND EXPERIMENTAL HEALTH SCIENCES | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Dental implants | |
| dc.subject | dental lasers | |
| dc.subject | fracture strength test | |
| dc.subject | surface treatments | |
| dc.subject | CAD/CAM | |
| dc.subject | BIAXIAL FLEXURAL STRENGTH | |
| dc.subject | Y-TZP ZIRCONIA | |
| dc.subject | PHASE-TRANSFORMATION | |
| dc.subject | MECHANICAL-BEHAVIOR | |
| dc.subject | BOND STRENGTH | |
| dc.subject | RESIN CEMENT | |
| dc.subject | ROUGHNESS | |
| dc.subject | CERAMICS | |
| dc.subject | RELIABILITY | |
| dc.subject | Medicine, Research & Experimental | |
| dc.subject | Research & Experimental Medicine | |
| dc.title | Investigation of Fracture Resistance of Zirconia Restorations After Different Surface Treatments | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.trdizin | 0 | |
| rdl.citation.wos | 0 | |
| rdl.department | SAKARYA ÜNİVERSİTESİ | |
| rdl.department | ERZİNCAN BİNALİ YILDIRIM ÜNİVERSİTESİ | |
| rdl.oa.status | green | |
| rdl.source.index | WOS | |
| rdl.source.index | TRDIZIN | |
| rdl.wos.index | Emerging Sources Citation Index (ESCI) |
