EFFECTS OF RECTANGULAR-SHAPED TURBULATORS ON HEAT TRANSFER, FRICTION FACTORS, AND ENTROPY

ArticleAçık Erişim

Özet

In this study, the effects of turbulators with different P ratios placed in a circular cross-section test pipe under turbulent flow conditions using water as the working fluid on heat transfer, friction factor (f), and entropy production were investigated using Ansys-Fluent 2021. The lowest Nu was calculated as 111 at Re=11825 for P=6, while the highest Nu was calculated as 219 at Re=19133 for P=1. The increase in Nu values for P = 6, 3, 2, 1.5, 1.2, and 1 compared to the plain pipe is 10.34%-11.64%; 17.39%-18.78%; 25.31%-26.56%; 34.42%-35.88%; 43.53%-44.87%; and 50.36%-51.47%, respectively. In turbulent situations, the highest entropy production rate was found to be 0.3631 W/mK at Re=11825 for P=6, while the lowest entropy production rate was found to be 0.2215 W/mK at Re=19133 for P=1. The minimum and maximum Ns reduction compared to the empty pipe was calculated as 7.13% for Re=19133 at P=6 and 46.62% for Re=11825 at P=1, respectively. In turbulent conditions, the highest Bejan number was found to be 0.9931 at Re=11825 for P=6. As a result, it was concluded that a ratio of P=1 provides maximum benefit in terms of heat transfer, while a ratio of P=6 is ideal in terms of total entropy production.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/17341Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.17482/uumfd.1676540Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorFIRAT, İLKER
dc.date.accessioned2026-10-18T20:49:28.560191578Z
dc.date.available2026-10-18T20:49:28.560191578Z
dc.date.issued2025
dc.description.abstractIn this study, the effects of turbulators with different P ratios placed in a circular cross-section test pipe under turbulent flow conditions using water as the working fluid on heat transfer, friction factor (f), and entropy production were investigated using Ansys-Fluent 2021. The lowest Nu was calculated as 111 at Re=11825 for P=6, while the highest Nu was calculated as 219 at Re=19133 for P=1. The increase in Nu values for P = 6, 3, 2, 1.5, 1.2, and 1 compared to the plain pipe is 10.34%-11.64%; 17.39%-18.78%; 25.31%-26.56%; 34.42%-35.88%; 43.53%-44.87%; and 50.36%-51.47%, respectively. In turbulent situations, the highest entropy production rate was found to be 0.3631 W/mK at Re=11825 for P=6, while the lowest entropy production rate was found to be 0.2215 W/mK at Re=19133 for P=1. The minimum and maximum Ns reduction compared to the empty pipe was calculated as 7.13% for Re=19133 at P=6 and 46.62% for Re=11825 at P=1, respectively. In turbulent conditions, the highest Bejan number was found to be 0.9931 at Re=11825 for P=6. As a result, it was concluded that a ratio of P=1 provides maximum benefit in terms of heat transfer, while a ratio of P=6 is ideal in terms of total entropy production.
dc.identifier.doi10.17482/uumfd.1676540
dc.identifier.eissn2148-4155
dc.identifier.endpage922
dc.identifier.issn2148-4147
dc.identifier.issue3
dc.identifier.startpage903
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/17341
dc.identifier.volume30
dc.language.isoen
dc.relation.ispartofUludağ Üniversitesi Mühendislik Fakültesi Dergisi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectFizik
dc.subjectUygulamalı
dc.subjectEnerji ve Yakıtlar
dc.titleEFFECTS OF RECTANGULAR-SHAPED TURBULATORS ON HEAT TRANSFER, FRICTION FACTORS, AND ENTROPY
dc.typeArticle
dspace.entity.typePublication
rdl.citation.trdizin0
rdl.departmentERZİNCAN BİNALİ YILDIRIM ÜNİVERSİTESİ
rdl.source.indexTRDIZIN