Synchrophasor Estimation Based on Quadrature Amplitude Modulation Using Artificial Ecosystem Optimization Algorithm

ArticleAçık Erişim

Özet

The need to monitor power quality and detect faults in the power grid has increased due to diverse generation sources and growing loads, which create supply-demand imbalances. Synchrophasor measurements are used to address these issues and assess system stability. This study proposes using Quadrature Amplitude Modulation (QAM) for synchrophasor measurement. Initially, the power signal’s frequency is estimated using the Artificial Ecosystem Optimization (AEO) algorithm. This estimated frequency serves as a reference for the QAM method. The power signal is then decomposed into positive and negative components based on this frequency. A moving average filter, acting as a low-pass filter, is applied to remove high-frequency noise and retain components aligned with the estimated frequency. As a result, the amplitude and phase of the desired frequency component are extracted. The method’s effectiveness is evaluated based on the IEEE Std. C37.118.1 for both M and P classes. Results show that the proposed approach achieves phasor estimation errors within the acceptable limits defined by the standard. Moreover, its performance at 80 dB SNR is compared with recent methods from literature, demonstrating its superiority in synchrophasor estimation, particularly under steady- state and harmonic conditions.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/17394Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.29137/ijerad.1620378Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAltintasi, Cagri
dc.contributor.authorŞENGÜL, ALPEREN
dc.date.accessioned2026-10-18T20:49:30.552666717Z
dc.date.available2026-10-18T20:49:30.552666717Z
dc.date.issued2025
dc.description.abstractThe need to monitor power quality and detect faults in the power grid has increased due to diverse generation sources and growing loads, which create supply-demand imbalances. Synchrophasor measurements are used to address these issues and assess system stability. This study proposes using Quadrature Amplitude Modulation (QAM) for synchrophasor measurement. Initially, the power signal’s frequency is estimated using the Artificial Ecosystem Optimization (AEO) algorithm. This estimated frequency serves as a reference for the QAM method. The power signal is then decomposed into positive and negative components based on this frequency. A moving average filter, acting as a low-pass filter, is applied to remove high-frequency noise and retain components aligned with the estimated frequency. As a result, the amplitude and phase of the desired frequency component are extracted. The method’s effectiveness is evaluated based on the IEEE Std. C37.118.1 for both M and P classes. Results show that the proposed approach achieves phasor estimation errors within the acceptable limits defined by the standard. Moreover, its performance at 80 dB SNR is compared with recent methods from literature, demonstrating its superiority in synchrophasor estimation, particularly under steady- state and harmonic conditions.
dc.identifier.doi10.29137/ijerad.1620378
dc.identifier.eissn1308-5514
dc.identifier.endpage524
dc.identifier.issue3
dc.identifier.startpage509
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/17394
dc.identifier.volume17
dc.language.isoen
dc.relation.ispartofUluslararası Mühendislik Araştırma ve Geliştirme Dergisi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectMühendislik
dc.subjectElektrik ve Elektronik
dc.subjectBilgisayar Bilimleri
dc.subjectYapay Zeka
dc.titleSynchrophasor Estimation Based on Quadrature Amplitude Modulation Using Artificial Ecosystem Optimization Algorithm
dc.typeArticle
dspace.entity.typePublication
rdl.citation.trdizin0
rdl.departmentERZİNCAN BİNALİ YILDIRIM ÜNİVERSİTESİ
rdl.departmentİZMİR DEMOKRASİ ÜNİVERSİTESİ
rdl.source.indexTRDIZIN