Evaluation Of BIS-GMA Release In Different Types Of Composites

ArticleAçık Erişim

Özet

BIS-GMA is frequently is involved in the structure of composite materials and may remain unpolymerized after polymerization. Residual Bis-GMA has harmful effects, it is crucial to determine the amounts released monomer from dental materials. The aim of this study is to compare residual BIS-GMA amounts in three types of composite. A total of 45 (n=15) composite (Filtek Ultimate Universal Restorative,3M ESPE,Germany), flowable composite (Nextcomp Flow,Meta Biomed,Kore), bulk fill composite(Tetric N Ceram, Ivoclar,Lichtenstein) cylindrical samples were polymerized in Teflon molds in accordance with the manufacturer's instructions. The samples were placed in 1.5ml ethanol (Carlo Erba, Pharm. Grade, 99.9%) and kept at 37oC. Monomer release of the samples was evaluated on the first, third and seventh days using the High Performance Liquid Chromatography technique. BIS-GMA release was shown with the highest amounts within all groups on the first day. The elution in composite fillings was significantly lower than the other materials on the first day(p<0.05). The highest total emission rates were observed in the flowable composite. The material selected in clinical practice should be considered because the monomer release may vary depending on the composite type.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/18559Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.18185/erzifbed.865816Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorEGIL, EDIBE
dc.contributor.authorKaraca, Serhat
dc.contributor.authorDuman, Canan
dc.contributor.authorOZDOKUR, KEMAL VOLKAN
dc.contributor.authorCEYRAN, Ertuğrul
dc.date.accessioned2026-10-18T20:56:37.960584731Z
dc.date.available2026-10-18T20:56:37.960584731Z
dc.date.issued2021
dc.description.abstractBIS-GMA is frequently is involved in the structure of composite materials and may remain unpolymerized after polymerization. Residual Bis-GMA has harmful effects, it is crucial to determine the amounts released monomer from dental materials. The aim of this study is to compare residual BIS-GMA amounts in three types of composite. A total of 45 (n=15) composite (Filtek Ultimate Universal Restorative,3M ESPE,Germany), flowable composite (Nextcomp Flow,Meta Biomed,Kore), bulk fill composite(Tetric N Ceram, Ivoclar,Lichtenstein) cylindrical samples were polymerized in Teflon molds in accordance with the manufacturer's instructions. The samples were placed in 1.5ml ethanol (Carlo Erba, Pharm. Grade, 99.9%) and kept at 37oC. Monomer release of the samples was evaluated on the first, third and seventh days using the High Performance Liquid Chromatography technique. BIS-GMA release was shown with the highest amounts within all groups on the first day. The elution in composite fillings was significantly lower than the other materials on the first day(p<0.05). The highest total emission rates were observed in the flowable composite. The material selected in clinical practice should be considered because the monomer release may vary depending on the composite type.
dc.identifier.doi10.18185/erzifbed.865816
dc.identifier.eissn2149-4584
dc.identifier.endpage305
dc.identifier.issn1307-9085
dc.identifier.issue1
dc.identifier.startpage299
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/18559
dc.identifier.volume14
dc.language.isoen
dc.relation.ispartofErzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectDiş Hekimliği
dc.subjectKimya
dc.subjectTıbbi
dc.titleEvaluation Of BIS-GMA Release In Different Types Of Composites
dc.typeArticle
dspace.entity.typePublication
rdl.citation.trdizin0
rdl.departmentİSTANBUL GELİŞİM ÜNİVERSİTESİ
rdl.departmentERZİNCAN BİNALİ YILDIRIM ÜNİVERSİTESİ
rdl.departmentİSTANBUL ATLAS ÜNİVERSİTESİ
rdl.departmentAĞRI İBRAHİM ÇEÇEN ÜNİVERSİTESİ
rdl.source.indexTRDIZIN