A Dramatic Complication: Iatrogenic Radial Artery Perforation

ArticleAçık Erişim

Özet

A 75 years old woman patient was admitted with a non-ST-segment elevation myocardial infarction. After insertion of a 6F radial sheath into the right radial artery and intra-arterial administration of heparin plus verapamil, 0.035 inch guidewire and catheter could not be advanced under fluoroscopic guidance. Immediately afterwards, radial angiography was performed, which displayed a radial artery per- foration with significant contrast extravasation. Held in place for 20 minutes with application of external compression with a sphygmo- manometer cuff at the level of systolic blood pressure. We used balloon assisted tracking and guide catheter tamponade tecnique to complete the angioplasty procedure via the radial artery and successfully seal the radial artery perforation. We describe a case where this technique was used to both treat radial artery perforation and to complete the angioplasty via the radial approach.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/20222Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorBuyuklu, Mutlu
dc.contributor.authorDeğirmenci, Hüsnü
dc.contributor.authorBAKIRCI, EFTAL MURAT
dc.contributor.authorHamur, Hikmet
dc.date.accessioned2026-10-18T21:12:05.252826177Z
dc.date.available2026-10-18T21:12:05.252826177Z
dc.date.issued2018
dc.description.abstractA 75 years old woman patient was admitted with a non-ST-segment elevation myocardial infarction. After insertion of a 6F radial sheath into the right radial artery and intra-arterial administration of heparin plus verapamil, 0.035 inch guidewire and catheter could not be advanced under fluoroscopic guidance. Immediately afterwards, radial angiography was performed, which displayed a radial artery per- foration with significant contrast extravasation. Held in place for 20 minutes with application of external compression with a sphygmo- manometer cuff at the level of systolic blood pressure. We used balloon assisted tracking and guide catheter tamponade tecnique to complete the angioplasty procedure via the radial artery and successfully seal the radial artery perforation. We describe a case where this technique was used to both treat radial artery perforation and to complete the angioplasty via the radial approach.
dc.identifier.endpage145
dc.identifier.issn1300-4778
dc.identifier.issue3
dc.identifier.startpage143
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/20222
dc.identifier.volume25
dc.language.isotr
dc.relation.ispartofMN Kardiyoloji
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectGenel ve Dahili Tıp
dc.subjectKalp ve Kalp Damar Sistemi
dc.titleA Dramatic Complication: Iatrogenic Radial Artery Perforation