Bu dergideki yayınlar
2 →- ArticleAçık Erişim2025Magnetic resonance arthrography with positional manoeuvre for the diagnosis of synovial fold of posterior shoulder joint capsule
Keles, Papatya; Ogul, Hayri; Tuncer, Kutsi; Sakci, Zakir; Ay, Mutlu; Kantarci, Mecit
Objectives: The objective of this study is to prospectively assess the effectiveness of shoulder magnetic resonance (MR) arthrograms with positional manoeuvres in detecting posterior synovial folds. Methods: Two radiologists independently assessed all axial MR arthrograms in internal rotation, neutral position, and external rotation for the presence of a posterior synovial fold. The diagnostic performances of the MR arthrograms were then compared, with results validated through arthroscopy. Results: Arthroscopy was performed on 81 of the 150 patients included in the study. A posterior synovial fold was identified arthroscopically in eleven of these patients. Measurements of the posterior synovial fold obtained in external rotation and the neutral position of the arm showed a significant correlation with arthroscopic results (p < 0.05). For detecting the posterior synovial fold with arthroscopic correlation, the sensitivity and specificity values for observer 1 and observer 2 were 100–81.4% and 100–88.6%, respectively, for MR arthrograms in the neutral position; 100–52.9% and 100–62.9% for MR arthrograms in external rotation; and 100–95.7% and 81.8–98.6% for MR arthrograms in internal rotation. There was a fair agreement for MR arthrography in external rotation for detecting posterior synovial folds, while MR arthrograms in internal rotation and neutral position showed near-perfect and significant interobserver agreement. Conclusion: The rotational positions of the humeral neck during MR arthrographic examination can influence the diagnostic specificity and sensitivity of axial MR arthrograms in detecting the posterior synovial fold. Clinical relevance statement: The posterior synovial fold can mimic a posterior labral detachment. Therefore, its correct identification is crucial in order to avoid unnecessary surgical procedures. Key Points: Movement of the shoulder may introduce variability in MR arthrography appearance. Rotation of the humeral neck during MR arthrography can affect diagnoses in posterior synovial fold detection. Given that posterior synovial folds can imitate posterior labral detachment, their correct identification is crucial to avoid unnecessary surgical procedures.
RDL Kalıcı Kaydıİncele - ArticleYayıncıda açık erişim2023Detection of the glenoid bare spot by non-arthrographic MR imaging, conventional MR arthrography, and 3D high-resolution T1-weighted VIBE MR arthrography: comparison with CT arthrography
Ozel, Mehmet Ali; Ogul, Hayri; Koksal, Ali; Kose, Mehmet; Tuncer, Kutsi; Eren, Suat; Kantarci, Mecit
Objectives: To determine the diagnostic accuracy of non-arthrographic MR imaging, conventional MR arthrography, and 3D T1-weighted volumetric interpolated breath-hold examination (VIBE) MR arthrography sequences as compared with a CT arthrography in the diagnosis of glenoid bare spot. Methods: A retrospective study of 216 patients who underwent non-arthrographic MR imaging, conventional MR arthrography, VIBE MRI arthrography, and CT arthrogram between January 2011 and March 2022 was conducted. The diagnostic accuracy of non-arthrographic MR imaging, direct MR arthrography, and VIBE MRI arthrography in the detection of glenoid bare spot was compared with that of CT arthrography. All studies were reviewed by 2 MSK radiologists. Interobserver agreement for MR imaging and MR arthrographic findings was calculated. Results: Sixteen of 216 patients were excluded. Twenty-three of 200 shoulders had glenoid bare spot on CT arthrographic images. The glenoid bare spot was detected in 11 (47.8%) and 7 (30.4%) patients on conventional non-arthrographic MR images and in 18 (78.3%) and 16 (69.6%) patients on conventional MR arthrograms by observers 1 and 2, respectively. Both observers separately described the bare spot in 22 of 23 patients (95.7%) on 3D volumetric MR arthrograms. Interobserver variabilities were fair agreement for conventional non-arthrographic MR imaging (κ = 0.35, p < 0.05), moderate agreement for conventional MR arthrogram (κ = 0.50, p < 0.05), and near-perfect agreement for 3D volumetric MR arthrogram reading (κ = 0.87, p < 0.05). Conclusions: A 3D high-resolution T1-weighted VIBE MR arthrography sequence may yield diagnostic performance that is comparable with that of CT arthrography in the diagnosis of glenoid bare spot. Key Points: •Glenoid bare spot should not be misdiagnosed as a transchondral defect of the glenoid surface by radiologists. •A 3D high-resolution T1-weighted VIBE MR arthrography sequence may be used as a high-sensitivity imaging technique in the diagnosis of glenoid bare spot.
RDL Kalıcı Kaydıİncele
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| creativeworkseries.issn | 0938-7994 | |
| creativeworkseries.issn | 1432-1084 | |
| dc.date.accessioned | 2026-10-20T15:35:41.080564937Z | |
| dc.date.available | 2026-10-20T15:35:41.080564937Z | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/23701 | |
| dc.publisher | Springer Science and Business Media Deutschland GmbH | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.title | European Radiology | |
| dspace.entity.type | Journal |
