Bu dergideki yayınlar
4 →- ArticleAçık Erişim2022Comparison of the clinical effects of two different doses (0.05% and 0.1%) of topical cyclosporine A in dry eyes with meibomian gland dysfunction; [Comparação de efeitos clínicos de duas doses diferentes (0,05% e 0,1%) de ciclosporina A tópica em olhos secos com disfunção da glândula tarsal]
Bayrakceken, Kemal; Ugurlu, Adem
Objective: To compare the clinical efficacy of two different doses of topical cyclosporine A used in addition to artificial tears in the treatment of patients with meibomian dysfunction and secondary dry eye. Methods: Fifty patients aged 18 to 40 years, who presented to our clinic between June 2020 and June 2021 were included in our study. Patients were divided into two groups as Group A (topical cyclosporine A 0.05%) and Group B (topical cyclosporine A 0.1%). All the patients underwent a detailed ophthalmological examination, basal Ocular Surface Disease Index measurement, and Schirmer 1 and tear break-up time tests at all visits. Results: The mean age was 32±7.1 years in Group A and 30.7±8.5 years in Group B. In Group A, there were 15 women and ten men, and Group B consisted of 14 women and 11 men. There was no difference between the groups in terms of age and gender distribution (p>0.05). Schirmer 1 and tear break-up time results and Ocular Surface Disease Index score also did not significantly differ between the groups (p>0.05). Conclusion: Cyclosporine A 0.05% and 0.1% eye drops were both seen to be effective in managing dry eye disease in patients with meibomian gland dysfunction.
RDL Kalıcı Kaydıİncele - ArticleAçık Erişim2021Comparison of prediction accuracy of five different biometric formulas; [Comparação da acurácia preditiva de cinco fórmulas biométricas diferentes]
Uğurlu, Adem; Altınkurt, Emre; Ergül, Elif
Objective: To compare the performance of Sanders-Retzlaff-Kraft/Theoretical, Hoffer Q, Barrett Universal II, Kane, and Hill-radial basis function formulas to calculate intraocular lens power in eyes with normal axial length, in terms of predicting target refraction by using partial coherence interferometry technology. Methods: Phacoemulsification and intraocular lens implantation were performed in 135 eyes of 135 patients with an axial length between 22 and 24.5 mm. Axial length, keratometry, and anterior chamber depth were measured by intraocular lens Master 500. Sanders-Retzlaff-Kraft/Theoretical, Hoffer Q, Barrett Universal II, Kane, and Hill-radial basis function formulas were used for intraocular lens power calculations. The difference between the expected postoperative refraction and the mean absolute prediction error was calculated for each eye. Statistical significance was evaluated at the level of p<0.05. Results: The study included 135 subjects. The mean axial length, anterior chamber depth, keratometry, and intraocular lens power were 23.2±1.2 (22 to 24.5) mm, 3.2±0.4 (2.4 to 4.4) mm, 43.5±1.5 (40.8 to 46.2) diopter, 21.5±1.8 (18.5 to 25.5) diopter, respectively. The mean absolute prediction error for Sanders-Retzlaff-Kraft/Theoretical, Hoffer Q, Barrett Universal II, Kane, and Hill-radial basis function was 0.306±0.291, 0.312±0.257, 0.314±0.268, 0.299±0.206 and 0.308±0.280, respectively (p>0.05). Conclusion: The study showed the third-generation (Sanders-Retzlaff-Kraft/Theoretical and Hoffer Q), fourth-generation (Barrett Universal II) and new-generation (Kane and Hill-radial basis function) intraocular lens power calculation formulas had similar performances regarding calculation of intraocular lens power to predict target refraction after phacoemulsification in eyes with normal axial length.
RDL Kalıcı Kaydıİncele - ArticleAçık Erişim2020Influence of sleep quality on macula and retinal nerve fiber layer in caucasian healthy adolescents: A cross-sectional assessment with optical coherence tomography; [Influência da qualidade do sono na mácula e na camada de fibras nervosas da retina de adolescentes caucasianos saudáveis: uma avaliação transversal por tomografia de coerência ótica]
Gamze Tas¸lı, Nurdan; Topal, Ismail; Yeter, Volkan
Objective: Poor sleep quality have affect on neuronal structure in central nervous system. We aimed to investigate the effects of sleep quality on the thickness of retinal nerve fiber layer (RNFL), macula, and ganglion cell complex (GCC) obtained by optical coherence tomography (OCT) in healthy Caucasian adolescents. Methods: In this prospective cross-sectional study,100 healthy adolescents were evaluated for determining of sleep quality score by the Pittsburgh sleep quality index(PSQI) and were monitored for detection of sleep efficiency(%) by Sense Wear PRO3 Armband mobile monitor(SWA). The sleep quality is evaluated based on the PSQI score and PSQI ≤5 was defined as “good sleep”, and a score >5 was defined as “poor sleep”. All subjects were scanned by spectral-domain OCT for the thicknesses of RNFL, GCC, and macular subfields. Results: Thirty nine of the subjects (39%) have poor sleep quality while 61 of them (61%) have good sleep. Inner superior (P=0.017), inner nasal (P=0.007), inner inferior (P=0.025), outer nasal (P= 0.011), and outer inferior (P=0.007) segments of macular thicknesses in the subjects with poor sleep are significantly thicker than those of the subjects with good sleep, whereas average RNFL of the adolescents with poor sleep is significantly thinner (P=0.02). All these parameters and central macular thickness have significant correlations with sleep efficiency and PSQI score (P<0.05).Conclusion: Sleep quality may have effects on macula and the nerve fiber layer of retina in adolescents and poor sleep may be related to decrease in the thickness of retinal nerve fiber layer.
RDL Kalıcı Kaydıİncele - ArticleYalnız künye2019Effects of two different contact lenses on ocular physiological parameters and tear function tests; [Efeitos de duas lentes de contacto diferentes nos parâmetros fisiológicos oculares e nos testes de função lacrimal]
Ugurlu, Adem; Ucak, Turgay; Karakurt, Yucel; Tasli, Nurdan Gamze; Icel, Erel; Yılmaz, Hayati
Objective: To investigate the effects of two types of contact lenses made of two different types of silicone hydrogel material on ocular physiological parameters and tear function tests. Methods: The contact lenses with the appropriate diopters were supplied to the volunteering patients. The patients were evaluated before wearing the contact lenses (visit0:V0), at the first month(visit1:V1) and at the thirth month(visit2:V2) following their wear. At all visits a detailed biomicroscopic examination was done, ocular physiological variables were collected, the tear function tests were performed and the tear meniscus area (TMA) was visualized and measured with anterior segment optical coherence tomography (AS-OCT). Results: The results of Schirmer 1 test were 12.07 ± 1.51 [9-16] mm for the right eyes (samfilcon A group) and 12.09 ± 1.5 [9-16] mm for the left eyes (senofilcon A group) at V0. (p=0.950) At V2, the mean Schirmer 1 test results were 11.92±1.34 [9-15] mm in the samfilcon A group and 12.2±1.41 [9-16] mm in the senofilcon A group (p=0.239). The mean TMA dimensions in the AS-OCT images were 338.42±47.1 [241-401] microns in the samfilcon A group and 338.42±47.1 [241-401] microns in the senofilcon A group at V0. (p>0.05). At V2, the mean TMA dimensions were 337.2±45.53 [241-402] microns in the samfilcon A group and 340.31±48.22 [240-411] microns in the senofilcon A group (p=0.728). Conclusions: Our study has demonstrated that contact lenses containing samfilcon A and senofilcon A silicone hydrogel material do not cause meaningful ocular surface problems
RDL Kalıcı Kaydıİncele
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| creativeworkseries.issn | 0034-7280 | |
| dc.date.accessioned | 2026-10-20T15:38:22.699032959Z | |
| dc.date.available | 2026-10-20T15:38:22.699032959Z | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/24180 | |
| dc.publisher | Sociedade Brasileira de Oftalmologia | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.title | Revista Brasileira de Oftalmologia | |
| dspace.entity.type | Journal |