Bu dergideki yayınlar

1 →
  • Conference ObjectYalnız künye2021
    Cyclic loading test on highly corroded reinforced concrete columns

    Celik, Alper; Yalciner, Hakan; Kumbasaroglu, Atila; Turan, Ahmet Ihsan

    An experimental study was performed on five reinforced concrete (RC) columns to investigate the structural behavior of highly corroded RC columns. Four of the RC columns were corroded using an accelerated corrosion method for different corrosion levels at longitudinal bars as 15.4, 20.2, 27.3 and 28.3%. RC columns were tested under cyclic load for a constant axial load ratio of 0.40. After the loading test, the actual corrosion levels were obtained by extracting the longitudinal bars and stirrups following the breaking of the RC columns. Load-displacement curves, ductility ratios and energy absorption capacities of tested RC columns were obtained. Test results revealed that the ductility ratios of corroded RC columns should be determined in accordance with energy-based or bilateral failure criteria due to the misleading of increased ductility ratios of corroded RC columns based on the displacement method.

    RDL Kalıcı Kaydıİncele
Tam Kayıt
AlanDeğerDil
creativeworkseries.issn2617-4820
dc.date.accessioned2026-10-20T15:39:26.439946555Z
dc.date.available2026-10-20T15:39:26.439946555Z
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/24368
dc.publisherfib. The International Federation for Structural Concrete
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titlefib Symposium
dspace.entity.typeJournal