2 →- ArticleYayıncıda açık erişim2019The Application of Multi-Phase Power Distribution Line with Pure Energy Conversion
Can, Erol
This paper discusses the power transmission of a six-phase power line with a six-phase LPWM inverter. The 20 km long line with six-phase is formed to be fed from the 6-phase multi-level inverter. The structure of the line and the elements of the power line are given in the design phase. After that, mathematical analysis of the power line is done to present information on the line structure and the relationship between the variables of the line. In the application stage, the described line is operating in Matlab Simulink. The input voltage of the line, the voltage of the RC parallel filter on the line and the voltage of the 1MW load on the line are measured. Six phase flux of the power is measured according to b2 and b4 bus points. Harmonic distortion of created voltages is measured. The harmonic distortion of the voltage on the Z(2) impedance is 0.12%. This level of deterioration is well below the international standard of 5% and is an ideal result for loads that need a pure multi-phase magnetic field. 6-phase voltage is measured at 244V amplitude on a 6-phase load with 1 MVA power connecting the secondary side of the transformer. Then, the distortion of this voltage is close to zero. This result is highly desirable for a load on the power line. Based on the results obtained, the power is transmitted over a 20 km long line with high quality successfully.
RDL Kalıcı Kaydıİncele - ArticleYayıncıda açık erişim2019The Load Performance of Multi-Level Alternating Voltage Provided by Upgrade Effect
Can, Erol
In this paper, the applications of the multi-level inverter with a partial inductor are investigated on different loads. The operation of the inverter is given according to different conditions of the circuit at the six-part duty times. Mathematical equations for the inverter are forming according to the load which is resistive (R), inductive (L), and Capacitive (C) in serial connection. After describing the circuit structure, Matlab SIMULINK also simulates the circuit for loads that are RLC, and a single-phase asynchronous motor. While the voltage and current measurements for the RLC load are performed; measurements of the main winding current, auxiliary winding current, electromagnetic torque, speed are made on the asynchronous motor. RLC loads are operated at high current values such as 297A in order to examine the suitability of the proposed system for systems that may require high current. When the current harmonic distortions of RLC loads are observed, the distortion values are acceptable values that are lower than % 5 that is international standards of the IEEE. In another hand, despite the voltage is insufficient for supplying the motor at the motor application, the voltage is upgraded with the boost effect of the inverter. So, the voltage is both a multilevel and sufficient. According to the obtained results, it is shown that multi-level inverter design has been successfully performed by using partial inductor source.
RDL Kalıcı Kaydıİncele
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| creativeworkseries.issn | 0128-0198 | |
| creativeworkseries.issn | 2289-7526 | |
| dc.date.accessioned | 2026-10-20T15:48:06.886268058Z | |
| dc.date.available | 2026-10-20T15:48:06.886268058Z | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/25739 | |
| dc.publisher | UKM PRESS | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.title | JURNAL KEJURUTERAAN | |
| dspace.entity.type | Journal |