Sürdürülebilir Kalkınma Amaçları
Yayınlar
- MakaleYalnız künye2026Scopus SJRQ3Fabrication of a PVC Membrane Sensor Based on a HKUST-1 Metal-organic Framework for Direct Determination of Cysteamine in Pharmaceutical Formulation
Kaya, Lutfi; Coldur, Fatih; Kanberoglu, Gulsah Saydan
Background: The most common use of cysteamine is the treatment of cystinosis. Excessive intake of cysteamine can lead to serious side effects and health complications. Therefore, the monitoring of cysteamine levels is highly significant. Objective: Several techniques have been developed to measure cysteamine accurately. Many of these methods are constrained by various limitations, including labor-intensive pre-treatment procedures, sophisticated equipment, skilled operators, and costly consumables. The present study aims to fabricate a cysteamine-selective potentiometric sensor based on HKUST-1 metal-organic framework exhibiting a wider linear range and more sensitive potentiometric responses compared to the ion pair-based cysteamine-selective sensor that was developed previously. Methods: A novel PVC membrane cysteamine-selective sensor was fabricated by coating the membrane cocktail consisting of poly(vinyl chloride), HKUST-1 metal-organic framework, plasticizer (o-nitrophenyloctylether), and ionic additive (potassium tetrakis (4-chlorophenyl) borate) onto the conductive solid contact surface. The potentiometric performance characteristics of the sensor were evaluated in detail. Results: The sensor exhibits a linear response to cysteamine concentration in the range of 1.0×10−6 M -1.0×10−2 M (R2=0.9958) with a slope of 51.5 mV/decade and a detection limit of 8.0×10-7 M. It operates effectively within a pH range of 3.9-5.7 and displays a rapid response time. Conclusion: Compared to the cysteamine-selective sensor available in the literature, the current sensor stands out with its wider linear operating range and lower detection limit. The sensor consistently yields reproducible and stable potentiometric responses towards cysteamine. The fabricated cysteamine-selective sensor effectively quantifies cysteamine content in pharmaceutical formulations. 2026, Bentham Science Publishers
- MakaleYalnız künye2026Scopus SJRQ2Efficient fabrication of a benzydamine-selective PVC-membrane potentiometric sensor with broad dynamic range and ultra-low detection limit
Kircaer, Ozan; Kanberoglu, Gulsah Saydan; Coldur, Fatih
A potentiometric poly(vinyl chloride) (PVC) membrane benzydamine (BZD)-selective sensor based on potassium tetrakis(4-chlorophenyl)borate (KTpClPB) as an electroactive material was fabricated with a broad linear range and ultra-low detection limit in a straightforward, cost-effective, and efficient manner. As an outcome of the membrane optimization research, it was found that the membrane composition that exhibited the best potentiometric performance metrics among the studied membrane compositions was 32.0% (w/w) PVC, 67.0% (w/w) o-NPOE (o-nitrophenyloctyl ether), and 1.0% (w/w) KTpClPB. The sensor displayed a linear response to BZD within the concentration range of 1.0 × 10−8 to 1.0 × 10−2 mol L-1, achieving a detection limit of 5.0 × 10− 9 mol L-1 and a sensitivity of 56.6 mV decade−1. The electrodes possessed a rapid response time of about 10 s. The sensor’s analytical capability was demonstrated by accurately quantifying the benzydamine content in multiple pharmaceuticals with benzydamine as the active component, yielding high recovery values.
- MakaleAçık Erişim2026Scopus SJRQ3A novel PVC-membrane potentiometric sensor based on molecularly imprinted polymer for the determination of rhodamine B
Kanberoglu, Gulsah Saydan; Kaya, Nurcan; Coldur, Fatih; Hashemi-Moghaddam, Hamid; Soylak, Mustafa
A rhodamine B (RH-B)-imprinted functional polymer was synthesized by free radical polymerization, utilizing RH-B as the template, methacrylic acid as the functional monomer, and ethyleneglycol dimethylacrylate as the cross-linker. The synthesized RH-B-imprinted polymer was characterized by FT-IR measurements. A novel RH-B-selective potentiometric poly(vinyl chloride) (PVC) membrane sensor was fabricated using this newly synthesized RH-B-imprinted functional polymer as the ionophore. Membrane optimization studies revealed that the most satisfactory membrane composition, yielding the best potentiometric parameters, comprised 32.0% (w/w) PVC, 64.0% (w/w) dibutyl phthalate, 3.0% (w/w) RH-B-imprinted polymer, and 1.0% (w/w) potassium tetrakis(4-chlorophenyl)borate. Further investigations into the potentiometric performance characteristics of the optimum composition demonstrated that the sensor exhibited a linear response to RH-B within the concentration range of 1.0 × 10–7 to 1.0 × 10–2 M with a detection limit of 1.0 × 10–8 M and a near Nernstian slope of 67.37 mV/decade. The sensor’s analytical proficiency was evidenced by its precise quantification of RH-B in RH-B-spiked rose-water samples, resulting in satisfactory recovery rates.
- MakaleYalnız künye2026Scopus SJRQ2Fabrication of a high electrochemical performance MTOAC sensor and its use in perchlorate measurement
Kanberoglu, Gulsah Saydan; Kaya, Nurcan; Calimli, Mehmet Harbi; Coldur, Fatih
The detection of perchlorate in some environmental and medical samples has been investigated by various research groups. However, due to its low detection limit and wide operating range, sensitive and selective perchlorate detection presents several challenges and requires costly analytical methods. In this study, methyltrioctylammonium chloride (MTOAC) was successfully used as an ionophore for the determination of perchlorate (ClO4−). The MTOAC ionophore-containing sensor demonstrated superior potentiometric properties, including a fast response time of 15 s, a wide linear operating range of 1.0 × 10− 2 to 7.5 × 10− 8 M, a low detection limit of 6.8 × 10− 8 M, a wide pH operating range of 3.36–9.65, and high repeatability at perchlorate concentrations of 10− 4 to 10− 6 M. Additionally, the MTOAC sensor showed high recovery (99.4-102.3%) in different water samples obtained from tap water, wastewater, spring water and Van Lake water. Compared to the sensors reported in the literature, the MTOAC sensor exhibited a wider linear working range and a lower detection limit. The low production cost, short response time, the absence of pretreatment, ease of use without requiring expertise, and the ability to operate even in turbid solutions make the MTOAC ionophore-containing membrane-based sensor a promising alternative for practical analytical applications.
- MakaleYalnız künye2026Scopus SJRQ3Design of a New Maprotiline-Selective Potentiometric Sensor Based on Metal-Organic-Framework/Imprinted Polymer Composite With Ultra-Broad Dynamic Range and Nanomolar Detection Limit
Kanberoglu, Gulsah Saydan; Kaya, Nurcan; Coldur, Fatih; Hashemi-Moghaddam, Hamid; Soylak, Mustafa
This study presents the development of a novel ion-selective electrode (ISE) for the selective and sensitive potentiometric detection of maprotiline (MAP). Due to the limited number of electrochemical maprotiline-selective sensors in the literature and the lack of molecularly imprinted polymer (MIP)-based potentiometric sensors, this study employed a MAP-imprinted polymer/metal organic framework (MIP/MOF) hybrid material as the ionophore component in the membrane structure of the MAP-selective electrode for the first time. For the design of the sensor, a europium oxide metal-organic cage (Eu-MOF)-based MIP (Eu-MOF@MAP-MIP) was synthesized, which offers advantages for molecular imprinting due to its large surface area, tunable pore architecture, and adaptable chemical functionality. The sensor exhibited a wide linear operating range from 1.0 × 10−10 to 1.0 × 10−2 M, a near-Nernstian slope of 52.3 mV/decade, and a remarkably low detection limit of 9.0 × 10−11 M. The analytical applicability was demonstrated by using it as an indicator electrode in the potentiometric titration of MAP and by directly determining the MAP content in two commercial drug formulations. The obtained high recovery percentages solidly confirm the practical suitability and high accuracy of the developed sensor for MAP analysis in real and complex matrices.
- MakaleYalnız künye2025Scopus SJRQ3All-Solid-State Potentiometric Sensor Based on Carbon Paste Composite for the Selective Determination of Iodide Ions
Yilmaz, Semra; Coldur, Fatih
Abstract: In the current study, a potentiometric all-solid-state composite ion-selective electrode for the determination of iodide ions is described. The synthesized salicylaldehyde thiosemicarbazone-mercury(II) complex (SATSC-Hg(II)) (1 : 1) was applied as the electroactive material in the electrode structure. Various composite ion-selective electrodes were prepared with different compositions, including SATSC-Hg(II), graphite, multi-walled carbon nanotubes (MWCNTs), ionic additives, and some mediators (various plasticizers or paraffin oil) to identify the most effective composite sensing layer composition exhibiting satisfactory potentiometric characteristics. The sensing layer composition consisting of 10 mg SATSC-Hg(II) complex, 26 mg dioctyl phthalate plasticizer, 5 mg MWCNTs, 4 mg methyltrioctylammonium chloride, and 65 mg graphite yielded the most favorable potentiometric performance properties. The electrode demonstrated a linear operating range of 1.0 × 10–5 to 0.1 M, a slope value of 55.2 ± 0.2 mV/decade, a detection limit of (9.0 ± 0.2) × 10–6 M, a pH operating range of 4–8, and a response time of approximately 60 s. The proposed electrode also displayed reproducible, stable, and selective potentiometric response to iodide ions. The analytical application of the electrode involved its use as an indicator electrode in the titration of iodide ions in synthetic solutions and for the determination of KI content in a pharmaceutical used for the treatment of goiter by the multiple standard addition method. Compared to polymer membrane electrodes, the renewability and reusability of the sensing surface of the proposed electrode, its suitability for miniaturization, and its robust structure offer significant advantages.
AtıfScopus2WoS2OpenAlex3İncele
- MakaleAçık Erişim2025Scopus SJRQ4New PVC Membrane-Based Ion-Selective Electrode for Ultrasensitive Detection of Bismuth(III) with Sudan I
Aksar, Burak; Kanberoglu, Gulsh Saydan; Coldur, Fatih
Accurate and dependable measurement of bismuth is vital for ensuring the safety of drugs, managing industrial processes, and evaluating environmental pollution. In this study, a new potentiometric sensor that uses Sudan I as the electroactive material within poly(vinyl chloride) (PVC) membrane structure was designed. The sensor displayed a broad linear concentration range of 1.0 ×10-3 to 1.0 ×10-10 M, an ultra-low detection limit of 4.0 ×10-11 M, and a response time of 30 seconds. It retained stable performance across a pH range of 2.0–7.0 and had an operational lifetime of about one month. When compared to existing literature, the sensor's selectivity and detection limit were significantly enhanced. It was successfully utilized to determine bismuth species in pharmaceutical formulations. Potentiometric methods provide clear advantages over other analytical techniques, such as simplicity, cost-effectiveness, quick response, and high selectivity. This developed sensor is a valuable tool for bismuth(III) determination, especially in quality control and pharmaceutical analysis.
- MakaleYalnız künye2025Scopus SJRQ4Development of a novel PVC membrane lidocaine-selective potentiometric sensor based on MIL-53 (Al) metal organic framework as a functional material
Gumus, Seyhmus; Kanberoglu, Gulsah Saydan; Kaya, Nurcan; Coldur, Fatih
Lidocaine is the most commonly used local anesthetic and can be used to reduce the feeling of pain caused by the stability of the nerve membrane and the pain that occurs at the end of the nerve signals in the skin. Due to the fact that lidocaine overdose causes side effects, determination of lidocaine is of great importance. The present study presents the development of a novel, simple, low-cost and reliable PVC membrane lidocaine hydrochloride-selective potentiometric sensor based on MIL-53(Al) metal organic framework (MOF) as a selective sensing functional material. The proposed sensor exhibited a linear potentiometric response for lidocaine hydrochloride in the concentration range of 1.0 × 10−7M−1.0 × 10−1M with the potential change of 55.4 mV/decade and a detection limit of 5.0 × 10−8M. The response time and the pH working range of the sensor were determined as 10 s and 2.37–7.45, respectively. These performance characteristics denote that the potentiometric lidocaine hydrochloride-selective sensor has quite superior properties. The potentiometric application of the lidocaine hydrochloride-selective sensor was successfully applied in pharmaceutical preparations.
- MakaleAçık Erişim2024Scopus SJRQ3Development of a Composite Cu(II)-Selective Potentiometric Sensor Based on a Thiourea Derivative Symmetric Schiff Base
Yildirim, Ozden; Coldur, Fatih; Topcu, Cihan; Caglar, Bulent
In the present study, initially, a thiourea derivative symmetric Schiff base, (1E,3E)-1,3-bis(5-bromo-2-hydroxybenzylidene)thiourea, was synthesized and characterized by FTIR and SEM-EDX analysis. In addition, an all-solid-state composite Cu(II)-selective potentiometric sensor based on this synthesized compound as an electroactive substance was constructed. Optimization studies indicated that the composition of the optimum sensing composite exhibiting the best potentiometric characteristics was 3.0% Schiff base, 5.0 % multi-walled carbon nanotube (MWCNT), 20.0 % paraffin oil and 72.0% graphite by mass. The proposed sensor displayed a linear response in the concentration range of 5.0×10-6-1.0×10-1 M with a slope of 31.1 mV/decade and a detection limit of 5.0×10-7 M. The proposed sensor exhibited a fairly selective, stable (potential drift: 1.85 mV/h), and rapid (<10 s) response towards Cu(II) ions. Because of the magnitude of its potential drift, the sensor should be recalibrated along the analysis time at least half an hour apart. The sensor can employed safely in the samples with pHs in the range of 2.0-6.5. The lifetime of the fresh sensor surface was determined as 2 weeks. The most important advantage of the sensor is that the sensing composite surface is renewable (at least 10 times) and thus the sensor can be used many times for a long period of time. The analytical applications of the sensor were executed successfully by using the electrode in the potentiometric titration of Cu(II) ions with EDTA as an indicator electrode, in the direct determination of Cu(II) contents of spiked water samples, and in the determination of (w/w) Cu% content of a Turkish coin.
AtıfScopus7WoS7OpenAlex7İncele
- MakaleYalnız künye2024Scopus SJRQ1Highly selective and sensitive potentiometric determination of favipiravir in COVID-19 antiviral drug formulations
Topcu, Cihan; Aydin, Senanur; Atasoy, Betul Hilal; Yilmaz, Rabia Rana; Coldur, Fatih; Caglar, Bulent
In this study, a novel all-solid-state electrochemical sensor based on favipiravir-tetraphenylborate (FAV-TPB) electroactive material was developed and reported for FAV's highly selective and sensitive potentiometric determination in COVID-19 antiviral drug formulations. All-solid-state FAV selective sensor was fabricated by mixing and properly pressing FAV-TPB, graphite (G), multi-walled carbon nanotube (MWCNT), and paraffin oil (PO). In order to obtain the best sensor response, the sensor component ratios were optimized. The most satisfying response characteristics was obtained with the sensor composition FAV-TPB:G:MWCNT:PO in the ratio 32.5:42.5:5:20 (w/w %). The developed sensor displayed a wide linear near-Nernstian response to FAV over the concentration of 1.0 × 10−6 − 1.0 × 10−1 molL−1 with a slope of 53.6 ± 1.4 mV (R2 = 0.9997). The detection limits of the sensor was calculated as 6.0 × 10−7 molL−1, respectively. The dynamic response time of the sensor was 7 s, and the sensor exhibited fairly reproducible potentiometric responses. In the pH range of 6.0–8.0, the sensor's potential response was not affected by the pH change of the test solutions. The improved sensor had a wide temperature tolerance, and its response remained unchanged in the 10–40 ℃ temperature range. The interference effect of some chemical and biological species was evaluated by the matched potential method and separate solution method. The sensor worked stable for 12 weeks without any considerable change in its potential response. The analytical applications of the sensor were successfully carried out with the potentiometric titration of FAV with sodium tetraphenylborate solution and also the direct determination of favipiravir in COVID-19 antiviral drug formulations.
AtıfScopus10WoS8OpenAlex9İncele
- MakaleYalnız künye2024Scopus SJRQ2Fabrication of a novel potentiometric sensor based on graphite/carbon nanotube composite paste modified by lead(II)sulfide for efficient determination of copper(II) ions
Ogul, Gulhan; Coldur, Fatih; Cubuk, Osman
A simple fabrication route for an all-solid-state carbon paste Cu(II)-selective potentiometric sensor on the basis of composite sensing layer consisting of PbS microparticles, graphite (G), multi-walled carbon nanotube, and paraffin oil has been propounded. Optimization studies for sensing composite layer signified that the composite contained 10 mg PbS, 10 mg MWCNT, 60 mg G, and 20 mg PO exposed the most promising potentiometric performance properties. The sensor displayed a stable and selective linear response to Cu(II) ions in the concentration range of 1.0 × 10−6–1.0 × 10−2 M (R2 = 0.9992) with an average potential change of 30.2 mV/decade. Detection limit, response time, and life-span of the sensor were determined as 5.0 × 10−7 M, 15 s, and 3 weeks, respectively. The fabricated sensor was successfully used in practical applications, serving as an indicator electrode to determine the end-point of Cu(II) titrations and to measure Cu(II) content in Cu(II)-spiked tap water samples. Graphical abstract: (Figure presented.)
AtıfScopus1WoS1OpenAlex2İncele
- MakaleYalnız künye2023Scopus SJRQ3Construction of a novel Cu(II)-selective electrode with long life span based on 8-aminoquinoline functionalized bentonite
Dogan, Bilge; Coldur, Fatih; Caglar, Bulent; Ozdemir, Agah Oktay; Guner, Eda Keles; Ozdokur, Kemal Volkan
A novel 8-aminoquinoline-functionalized bentonite was utilized as an electroactive sensing element in the construction of a potentiometric carboxylated-PVC-based polymeric membrane electrode. The electrode exhibited a linear response for copper(II) ions in the concentration range of 1.0 × 10–5−1.0 × 10–2 mol/dm3 with a slope of 28.24 mV/decade. While the response time of the electrode determined as about 20 s, its detection limit and long life time was determined as 5.0 × 10–6 mol/dm3 and 5 months, respectively. The proposed electrode was applied for the potentiometric detection of Cu(II) contents of some spiked water samples and satisfied results were attained. Graphical abstract: [Figure not available: see fulltext.]
AtıfScopus5WoS3OpenAlex5İncele
- MakaleAçık Erişim2023Scopus SJRQ3A PVC-Membrane Cationic Surfactant Sensitive Potentiometric Sensor: Potentiometric Determination of Dodecyltrimethyl Ammonium Ion
Yalcin, Belgin; Coldur, Fatih; Caglar, Bulent; Topcu, Cihan
A potentiometric poly (vinyl chloride) (PVC) membrane cationic surfactant-selective sensor based on a dodecyltrimethylammonium-phosphotungstate ion pair as an electroactive material was suggested for the determination of dodecyltrimethylammonium bromide. Membrane optimization studies revealed that the PVC membrane in the composition of 0.5 % dodecyltrimethylammonium-phosphotungstate ion pair, 69.5 % o-nitrophenyloctylether and 30.0 % PVC displayed the best potentiometric performance properties. The sensor exhibited a linear response to dodecyltrimethylammonium ions in the concentration range of 1.0×10−6–1.0×10−2 mol L−1 with a detection limit and sensitivity of 5.0×10−7 mol L−1 and 56.6 mV/decade, respectively. The response of the sensor to dodecyltrimethylammonium cation was quite stable, sensitive, selective and rapid (<10 s). The life span of the sensor was found to be about 3 months. The analytical applications of the sensor were successfully carried out with the developed sensor as an indicator electrode for the determination of the end-point of dodecyltrimethylammonium ions titration and dodecyltrimethylammonium contents of synthetic water samples.
AtıfScopus7WoS6OpenAlex9İncele
- MakaleYalnız künye2022Scopus SJRQ2Solid-state Electrochemical Sensor Based on a Cross-linked Copper(II)-doped Copolymer and Carbon Nanotube Material for Selective and Sensitive Detection of Monohydrogen Phosphate
Topcu, Cihan; Coldur, Fatih; Caglar, Bulent; Ozdokur, K. Volkan; Cubuk, Osman
A novel solid-state electrochemical sensor based on a newly synthesized cross-linked copper(II) doped-copolymer and carbon nanotube material was developed for the direct determination of monohydrogen phosphate ions (HPO42−). The synthesized copolymers were characterized by FTIR, XPS, TG/DTG-DTA and SEM techniques. The sensor had a Nernstian slope:-30.7±0.4 mV/decade, linear concentrations range: 1.0×10−6 - 1.0×10−1 M, detection limit: 6.5×10−7 M, response time: 4 s and life time: 17 weeks. The sensor displayed constant potentials in the pH range 7.0-9.5. The sensor was successfully used as an indicator electrode in potentiometric titration and the direct determination of HPO42− in water samples.
AtıfScopus5WoS5OpenAlex9İncele
- MakaleYalnız künye2022Scopus SJRQ2Development of MOF-based PVC membrane potentiometric sensor for determination of imipramine hydrochloride
Subasi, Yaver; Kanberoglu, Gulsah S.; Coldur, Fatih; Cubuk, Osman; Zahmakiran, Mehmet
Imipramine hydrochloride (IMIP) is a tricyclic antidepressant utilized in the treatment of depression and chronic pain in some certain cases together with pain medication. The side effects of anxiety, insomnia, crying attacks, personality change and tachycardia are seen in imipramine overdose; therefore, determination of imipramine is an important issue. In this study, a novel potentiometric PVC membrane ion-selective sensor (ISE) was developed for monitoring of IMIP. MIL-53(Al) metal–organic framework was utilized for the first time as an electroactive material in the construction of imipramine-selective PVC membrane sensor. The sensor membrane consisting of 3.0% MIL-53(Al), 64.0% dibutylphthalate (DBP), 32.0% polyvinylchloride (PVC) and 1.0% potassium tetrakis(4-chlorophenyl)borate (KTPClPB) exhibited the most satisfied potentiometric performance characteristics. The sensor displayed a linear response for imipramine hydrochloride in the concentration range of 1.0 × 10−7 M-1.0 × 10−1 M with a slope of 57.7 mV/decade and detection limit of 5.0 × 10−8 M. The operational pH range of the sensor was determined as 3.7–8.5. The sensor showed highly reproducible and stable potentiometric responses with the response time of less than 5 s. The IMIP content of a pharmaceutical used in the treatment of depression was successfully determined with the proposed imipramine-selective sensor. Additionally, the analytical applicability of the sensor in real biological samples was demonstrated by performing imipramine determinations in spiked human blood serum and urine samples. Graphical abstract: [Figure not available: see fulltext.].
AtıfScopus16WoS16OpenAlex17İncele
- MakaleYalnız künye2022Scopus SJRQ2Development of a PVC Membrane Potentiometric Sensor with Low Detection Limit and Wide Linear Range for the Determination of Maprotiline in Pharmaceutical Formulations
Tekce, Serkan; Subasi, Yaver; Coldur, Fatih; Kanberoglu, Gulsah Saydan; Zahmakiran, Mehmet
Maprotiline (MAP), is an active ingredient of some antidepressants which has been broadly used for the therapy of depression. The overdose of MAP in the treatment of patients with depression can lead to significant side effects, even lethal intoxication. Therefore, it is very important to develop simple, inexpensive, fast and reliable detection methods for MAP in interested samples. In our present study, we have offered a novel poly(vinylchloride) (PVC) membrane maprotiline-selective potentiometric sensor based on a type of MOFs, known as MIL-53(Al), as electroactive ionophore substance. The sensor prepared at the optimum membrane composition exhibited a linear response for maprotiline hydrochloride in the concentration range of 1,0×10−9 M−1,0×10−2 M with a slope of 59,1 mV/decade and detection limit of 9,0×10−10 M. The pH working range of the sensor was determined as 2,0–9,5. The response time of the sensor was very fast and less than 5 s. With these performance features, it has been shown that the current sensor has quite superior features compared to the potentiometric MAP-selective sensor available in the literature. The potentiometric application of the sensor was successfully carried out with the detection of MAP in pharmaceutical tablets containing MAP-HCl.
AtıfScopus7WoS7OpenAlex8İncele
- MakaleYalnız künye2022Scopus SJRQ1Facile synthesis of TiO2-coated cotton fabric and its versatile applications in photocatalysis, pH sensor and antibacterial activities
Özdemir, Agah Oktay; Caglar, Bulent; Çubuk, Osman; Coldur, Fatih; Kuzucu, Mehmet; Guner, Eda Keles; Doğan, Bilge; Caglar, Sema; Özdokur, Kemal Volkan
TiO2 nanoparticles-coated cotton fabric was readily prepared by the hydrolysis of TiCl4 solution over cotton fabric and characterized various techniques in comparison with pristine cotton fabric. Initially, the photocatalytic application of the obtained fabric was carried out by using it as a catalyst for the photodegradation of rhodamine B. A higher degradation ratio for rhodamine B in the presence of TiO2-coated cotton fabric as photocatalyst was observed under visible light compared to the one performed under UVA. The reactive species trapping experiments revealed that the superoxide radicals played a major role than other radical species and two different degradation mechanisms were proposed according the trapping results. Subsequently, considering that the fabricated TiO2-coated cotton fabric is a very suitable sensor material for the development of a wearable flexible pH sensor, a potentiometric solid state pH sensor prototype was constructed and tested for pH measurements. The proposed prototype exhibited a linear potentiometric response in the pH range from 2.0 to 9.0 with a slope of −23.9 mV/decade. The pH accuracies (as relative error %) calculated for the current electrode with respect to the commercial electrode in the studied buffer solutions were ranged between −1.8% and 1.9%. The presently proposed pH electrode allowed pH measurements highly coherent with commercially available pH electrode. Finally, the antibacterial activity of the TiO2 nanoparticles was evaluated by minimum bactericidal concentration (MBC), minimum inhibitory concentration (MIC) testing and also antibacterial property of the TiO2 nanoparticles-coated cotton fabric was demonstrated by GB/T 20944.3–2008 method using Staphylococcus aureus (ATCC 6538) and Escherichia coli (ATCC 25922) as representative strains of Gram-positive and Gram-negative bacteria, respectively. This study would be indicative to design of nano metal oxide-coated cotton fabrics in the application of photocatalyst, pH sensor and antibacterial agent against bacteria.
AtıfScopus48WoS43OpenAlex50İncele
- MakaleAçık Erişim2020Scopus SJRQ3A novel potentiometric PVC-membrane cysteamine-selective electrode based on cysteamine-phosphomolybdate ion-pair
Tumur, Merve; Kanberoglu, Gulsah Saydan; Coldur, Fatih
Background: Cysteamine is used as an orphan drug in the treatment of cystinosis to prevent long-term cystine accumulation in lysosomes. Dosing in cysteamine treatment is extremely important and overdose may cause some side effects. Up to now, various analytical methods have been used for cysteamine determination. Many of these methods require sophisticated instruments, expert operators, time-consuming measurement procedures and manipulation steps, expensive supplies and long analysis time. Aims and Objective: The present study deals with the development of a potentiometric PVC-membrane cysteamine-selective electrode based on an ion-pair of cysteamine and its application in a pharmaceutical formulation. Methods: Cysteamine (Cys)-Phosphomolybdate (PM) ion-pair was synthesized by mixing the equal volumes of 10-2 M Cysteamine HCl and sodium phosphomolybdate aqueous solutions. The obtained precipitate was used as ionophore in the structure of PVC-membrane. Results and Discussion: The electrode exhibited a linear response in the concentration range of 1.0×10-1-1.0×10-5 M cysteamine with a slope of 51,7 mV per decade and detection limit of 1.0×10-5 M. The potentiometric response of the electrode was very rapid (5 s), adequately repeatable, stable and selective. pH working range and life-time of the electrode were also determined as 3.0-7.0 and 25 days, respectively. Conclusion: A PVC-membrane cysteamine selective electrode was easily prepared. Cysteamine determination in a pharmaceutical formulation was performed. Analysis results indicated that it can be successfully used in drug quality control laboratories for routine analysis of cysteamine in pharmaceutical preparations alternative to more sophisticated, expensive and time-consuming analytical methods.
AtıfScopus12WoS10OpenAlex12İncele
- MakaleYalnız künye2019Scopus SJRQ3Novel Copper(II)-Selective Potentiometric Sensor Based on a Folic Acid-Functionalized Carbon Nanotube Material
Topcu, Cihan; Caglar, Bulent; Guner, Eda Keles; Coldur, Fatih; Caglar, Sema; Yıldırım, Özden; Volkan Özdokur, Kemal; Cubuk, Osman
A folic acid-functionalized carbon nanotube nanomaterial was prepared by immobilizing folic acid molecules on the carbon nanotubes through covalent bonds. The material was characterized using Fourier transform infrared spectroscopy, energy-dispersive X-ray spectroscopy and scanning electron microscopy. Fourier transform infrared spectroscopy confirmed that folic acid molecules were grafted on the carbon nanotube surfaces through the amide bonds between the carboxylic acid functional groups of the oxidized carbon nanotubes and the amine groups of the folic acid molecules. The folic acid molecules bonded to carbon nanotube surfaces led to appreciable changes in the morphology. By using currently obtained folic acid-functionalized carbon nanotube nanomaterial as electroactive material in a polyvinyl chloride membrane, a potentiometric copper (II)-selective sensor was developed. Membrane optimization studies showed that the composition exhibiting the best potentiometric properties was 4.0% (w/w) folic acid–carbon nanotube, 64.0% (w/w) o-nitrophenyl octylether, and 32.0% (w/w) polyvinyl chloride. The developed sensor displayed a linear response in the copper (II) concentration ranging from 1.0 × 10–6 to 1.0 × 10–1 M with a correlation coefficient of 0.9993 and a slope of 29.8 ± 0.6 mV/decade of activity. The response time, detection limit, and pH working range were determined to be 4 s, 3.8 × 10–7 M and 4.0–8.0, respectively. The developed sensor showed highly selective and satisfactory potentiometric response for the determination of copper (II) in a Turkish coin.
AtıfScopus12WoS12OpenAlex13İncele
- MakaleYalnız künye2019Scopus SJRQ3Voltammetric detection of chlorite ion using carbon paste sensor modified with N-cetylpyridinium–bentonite
Cubuk, Osman; Colak, Isıl; Özdokur, Kemal Volkan; Caglar, Bulent; Coldur, Fatih; Topcu, Cihan
A voltammetric carbon paste sensor (CPS) was described for the detection of chlorite ion in water analysis. For the construction of the voltammetric CPS, organo-bentonites were synthesised by intercalation of N-cetylpyridinium (NCP) at different amounts into interlayer gap of bentonite. Some features of the obtained organo-bentonites such as structural, thermal and morphological were investigated by using various techniques. Afterwards, the voltammetric behaviour of the (Formula presented.) solution was investigated with cyclic voltammetry in the potential range of 0.0–1.0 V at a scan rate of 50 mV s−1 based on the obtained organo-bentonites as electroactive material. The characterisation of the prepared organo-bentonites as electroactive material, the effect of the amount of NCP–bentonite (NCP–B) in modified CPS on the 10.0 mM CIO2- response was tested by chancing the percentage of NCP–B in the range of 2.50–12.50% under identical experimental conditions. The pH of the measurement cell was optimised by using 0.04 M Britton–Robinson buffer in the range of pH 2.0–12.0. Under the optimised conditions, developed sensor exhibited a linear response in the range of 2.0 × 10−5 to 2.0 × 10−4 M chlorite ions concentrations. The detection limit and the limit of quantification were figured out as 6.0 × 10−6 and 2.0 × 10−5 M, respectively. The repeatability and reproducibility of the sensor were calculated as 5.0% and 6.8% (N = 5), respectively. Finally, the sensor was successfully applied for the analysis of bottled water, and the mean recovery was found as 103 ± 3%.
AtıfScopus3WoS3OpenAlex5İncele


