Fabrication of a high electrochemical performance MTOAC sensor and its use in perchlorate measurement

ArticleAçık Erişim

Özet

The detection of perchlorate in some environmental and medical samples has been investigated by various research groups. However, due to its low detection limit and wide operating range, sensitive and selective perchlorate detection presents several challenges and requires costly analytical methods. In this study, methyltrioctylammonium chloride (MTOAC) was successfully used as an ionophore for the determination of perchlorate (ClO4−). The MTOAC ionophore-containing sensor demonstrated superior potentiometric properties, including a fast response time of 15 s, a wide linear operating range of 1.0 × 10− 2 to 7.5 × 10− 8 M, a low detection limit of 6.8 × 10− 8 M, a wide pH operating range of 3.36–9.65, and high repeatability at perchlorate concentrations of 10− 4 to 10− 6 M. Additionally, the MTOAC sensor showed high recovery (99.4-102.3%) in different water samples obtained from tap water, wastewater, spring water and Van Lake water. Compared to the sensors reported in the literature, the MTOAC sensor exhibited a wider linear working range and a lower detection limit. The low production cost, short response time, the absence of pretreatment, ease of use without requiring expertise, and the ability to operate even in turbid solutions make the MTOAC ionophore-containing membrane-based sensor a promising alternative for practical analytical applications. © The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature 2025.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/10069Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s10008-025-06494-9Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKanberoglu, Gulsah Saydan
dc.contributor.authorKaya, Nurcan
dc.contributor.authorCalimli, Mehmet Harbi
dc.contributor.authorColdur, Fatih
dc.date.accessioned2026-10-18T20:25:19.229698728Z
dc.date.available2026-10-18T20:25:19.229698728Z
dc.date.issued2026
dc.description.abstractThe detection of perchlorate in some environmental and medical samples has been investigated by various research groups. However, due to its low detection limit and wide operating range, sensitive and selective perchlorate detection presents several challenges and requires costly analytical methods. In this study, methyltrioctylammonium chloride (MTOAC) was successfully used as an ionophore for the determination of perchlorate (ClO4−). The MTOAC ionophore-containing sensor demonstrated superior potentiometric properties, including a fast response time of 15 s, a wide linear operating range of 1.0 × 10− 2 to 7.5 × 10− 8 M, a low detection limit of 6.8 × 10− 8 M, a wide pH operating range of 3.36–9.65, and high repeatability at perchlorate concentrations of 10− 4 to 10− 6 M. Additionally, the MTOAC sensor showed high recovery (99.4-102.3%) in different water samples obtained from tap water, wastewater, spring water and Van Lake water. Compared to the sensors reported in the literature, the MTOAC sensor exhibited a wider linear working range and a lower detection limit. The low production cost, short response time, the absence of pretreatment, ease of use without requiring expertise, and the ability to operate even in turbid solutions make the MTOAC ionophore-containing membrane-based sensor a promising alternative for practical analytical applications. © The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature 2025.
dc.identifier.doi10.1007/s10008-025-06494-9
dc.identifier.eissn1433-0768
dc.identifier.endpage1319
dc.identifier.issn1432-8488
dc.identifier.issue3
dc.identifier.scopus2-s2.0-105024010990
dc.identifier.startpage1311
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/10069
dc.identifier.volume30
dc.identifier.wosWOS:001631516100001
dc.language.isoen
dc.publisherSpringer Science and Business Media Deutschland GmbH
dc.relation.ispartofJournal of Solid State Electrochemistry
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectDetection
dc.subjectMTOAC
dc.subjectPerchlorate
dc.subjectPotentiometric
dc.subjectSensor
dc.subjectChlorine compounds
dc.subjectResponse time (computer systems)
dc.subjectElectrochemical performance
dc.subjectEnvironmental sample
dc.subjectLow detection limit
dc.subjectMedical samples
dc.subjectMethyltrioctylammonium chloride
dc.subjectOperating ranges
dc.subjectPerchlorate detections
dc.subjectPotentiometrics
dc.subjectResearch groups
dc.subjectError detection
dc.titleFabrication of a high electrochemical performance MTOAC sensor and its use in perchlorate measurement
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus0
rdl.citation.wos0
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)