Experimental assessment of fanless thermoelectric cooling using a folded aluminum plate under natural convection

ArticleAçık Erişim

Özet

This study experimentally investigates the performance of a fanless thermoelectric cooling system operating under natural convection conditions, with particular emphasis on simple and cost-effective hot-side thermal management. A commercial TEC12703 module was integrated into a miniature refrigeration system consisting of a Styrofoam enclosure, where heat rejection from the hot side was achieved using a folded aluminum plate without any auxiliary cooling components such as fans, pumps, or heat pipes. The aluminum plate was geometrically modified to enhance heat dissipation while maintaining a small footprint and to reduce thermal interaction with the refrigerator wall by increasing the effective separation distance. Experiments were conducted at six different input voltages (3, 4, 5, 6, 7 and 8 V) to evaluate the voltage-dependent cooling behavior and overall system performance under passive cooling conditions. The results demonstrate that even with a simple plate-type heat spreader, stable operation of the thermoelectric module can be maintained, although hot-side temperature rise significantly influences cooling capacity and coefficient of performance (COP) as the input voltage increases. The folded plate configuration achieved up to approximately 2–3 °C lower cold space temperatures and about 15–20% higher COP values compared to the flat plate, particularly within the optimum operating voltage range of 5–6 V. The findings highlight the critical role of hot-side heat rejection in fanless thermoelectric systems and confirm that appropriately designed folded aluminum plates can provide a viable passive thermal management solution for low-power and compact refrigeration applications where simplicity, reliability, and low energy consumption are prioritized. © The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature 2026.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/10085Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s00231-026-03703-7Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorOzer, Rahim Aytug
dc.contributor.authorDoğuş Tuncer, Azim
dc.contributor.authorKhanlari, Ataollah
dc.contributor.authorSözen, Adnan
dc.contributor.authorKılınç, Cuma
dc.contributor.authorAfshari, Faraz
dc.date.accessioned2026-10-18T20:25:20.238567007Z
dc.date.available2026-10-18T20:25:20.238567007Z
dc.date.issued2026
dc.description.abstractThis study experimentally investigates the performance of a fanless thermoelectric cooling system operating under natural convection conditions, with particular emphasis on simple and cost-effective hot-side thermal management. A commercial TEC12703 module was integrated into a miniature refrigeration system consisting of a Styrofoam enclosure, where heat rejection from the hot side was achieved using a folded aluminum plate without any auxiliary cooling components such as fans, pumps, or heat pipes. The aluminum plate was geometrically modified to enhance heat dissipation while maintaining a small footprint and to reduce thermal interaction with the refrigerator wall by increasing the effective separation distance. Experiments were conducted at six different input voltages (3, 4, 5, 6, 7 and 8 V) to evaluate the voltage-dependent cooling behavior and overall system performance under passive cooling conditions. The results demonstrate that even with a simple plate-type heat spreader, stable operation of the thermoelectric module can be maintained, although hot-side temperature rise significantly influences cooling capacity and coefficient of performance (COP) as the input voltage increases. The folded plate configuration achieved up to approximately 2–3 °C lower cold space temperatures and about 15–20% higher COP values compared to the flat plate, particularly within the optimum operating voltage range of 5–6 V. The findings highlight the critical role of hot-side heat rejection in fanless thermoelectric systems and confirm that appropriately designed folded aluminum plates can provide a viable passive thermal management solution for low-power and compact refrigeration applications where simplicity, reliability, and low energy consumption are prioritized. © The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature 2026.
dc.description.sponsorshipThe authors gratefully acknowledge Zahit Al\u00FCminyum (Adana, T\u00FCrkiye) for providing the aluminum components used in the experimental setup of this study.
dc.identifier.doi10.1007/s00231-026-03703-7
dc.identifier.eissn1432-1181
dc.identifier.issn0947-7411
dc.identifier.issue6
dc.identifier.scopus2-s2.0-105039694589
dc.identifier.startpage72
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/10085
dc.identifier.volume62
dc.identifier.wosWOS:001771228700002
dc.language.isoen
dc.publisherSpringer Science and Business Media Deutschland GmbH
dc.relation.ispartofHeat and Mass Transfer/Waerme- und Stoffuebertragung
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAluminum
dc.subjectCoefficient of performance
dc.subjectCost effectiveness
dc.subjectHeating equipment
dc.subjectNatural convection
dc.subjectRefrigerators
dc.subjectTemperature control
dc.subjectThermoelectric equipment
dc.subjectThermoelectric refrigeration
dc.subjectThermoelectricity
dc.subjectThermography (temperature measurement)
dc.subjectAluminium plates
dc.subjectCondition
dc.subjectExperimental assessment
dc.subjectHeat rejection
dc.subjectInput voltages
dc.subjectPerformance
dc.subjectSimple++
dc.subjectThermal
dc.subjectThermoelectric cooling
dc.subjectAluminum plating
dc.titleExperimental assessment of fanless thermoelectric cooling using a folded aluminum plate under natural convection
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus0
rdl.citation.wos1
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)